background image

20

21

EN

Monitoring

The CO alarm self-checks vital functions to ensure that it is operating correctly.

1

  Low battery fault – the battery voltage is measured and compared against a low voltage 

threshold.

2

  Sensor Fault – the sensor is checked for electrical continuity and open circuit.

3

  End of life fault – The alarm is programmed to check when the useful life of the alarm has 

been exceeded.

Low battery

If the battery is starting to be depleted, the CO alarm beeps, the yellow LED blinks once every 

minute and the red LED on the Visit receiver blinks. Replace the CO alarm. The low battery 

beeps on the CO alarm can be supressed for 24 hours by pressing the button. 

Sensor fault 

If a sensor fault has been detected, the CO alarm beeps, the yellow LED blinks twice every 

minute and the red LED on the Visit receiver blinks. Replace the CO alarm.

End of life

When the sensor has reached its end of life, the CO alarm beeps, the yellow LED blinks 3 times 

every minute and the red LED on the Visit receiver blinks. Replace the CO alarm.

Testing

Frequent testing of the CO alarm is a requirement to ensure that the power is present, and the 

unit is functioning. Guidelines and best practices for testing are as follows:

1

  After the system is installed.

2

  Once monthly thereafter.

3

  After prolonged absence from the dwelling (e.g. after a holiday period).

4

  After repair or servicing of any of the systems elements or household electrical works.

To test the CO alarm, press and hold the test/hush button. The unit will respond with one of 

the following status conditions:

The Green LED on the CO alarm blinks and the horn sounds to indicate the unit is powered 

and operating correctly. The orange and red LEDs on the Visit receiver blink alternately and 

it it starts to sound, flash or vibrate depending on the receiver.

2

  If there is a fault condition, the yellow LED on the CO alarm blinks and the horn beeps in 

accordance with the 

Signal pattern

 table on page 28. The red LED on the Visit receiver blinks.

 

Response to CO gas

The presence of CO gas is indicated by the blinking red led on the unit. We do not recom-

mend testing the alarm with carbon monoxide as the results can be misleading unless 

special apparatus is used. However, if testing the unit with CO gas is required, once the red 

LED is blinking, indicating the presence of CO gas, momentarily press the test/hush button 

and within seconds the horn will sound 2 alarm pattern cycles.

Maintenance

Silencing (Hush)

When the alarm sounds, after sensing CO, pressing the test/hush button will immediately stop 

the horn (the red LED will continue to blink). If CO is still present, the horn will turn on again 

after about 4 minutes. The CO alarm can only be silenced once during a CO incident. At levels 

> 150ppm CO the unit cannot be silenced.

Cleaning the CO alarm

 

Clean the outside case by occasionally wiping with a clean damp cloth. 

 

Do not use any cleaning agents, bleaches, detergents or polishes, including those in 

aerosol cans. Avoid spraying air fresheners, hair spray, paint or other aerosols near the CO 

alarm. Do not place air fresheners near the CO alarm.

Summary of Contents for BE1555

Page 1: ...BE1555 VISIT CO DETECTOR...

Page 2: ...CO Sensor Blue Red Yellow Green BE1555 Medical device information 6 Installation 10 Signal pattern 11 Changing the radio key 12 Facts about carbon monoxide 14 Location and positioning 16 Monitoring t...

Page 3: ...ystem consists of a set of wirelessly connected transmitters and receivers that are located across the home When a transmitter detects an activity it signals the Visit receiver that alerts the user wi...

Page 4: ...ss Park Ellesmere Port Cheshire CH65 3EN UK Humidity during transportation and storage 95 non condensing Humidity during operation 15 to 95 non condensing Operating conditions This device is designed...

Page 5: ...the alarm sounds and the CO source is unknown Note that the alarm may sound if cigarette smoke is blown into it or aerosols are released nearby Depending on the cause of the alarm the signal patterns...

Page 6: ...radio key has been changed RADIO ALARM FAULT POWER TEST PUSH CARBON MONOXIDE ALARM RADIO ALARM FAULT POWER TEST PUSH CARBON MONOXIDE ALARM Systems with only BE1555 CO alarms Changing the radio key on...

Page 7: ...a loud alarm if the CO persists The Signal pattern ta ble on page 28 shows how the CO alarm reacts to different levels of CO gas and exposure time At higher levels of CO the alarm turns on sooner The...

Page 8: ...ghts Where it would be obstructed e g by curtains or furniture Directly above a sink or cooker Over heat sources such as radiators or hot air vents In an area where the temperature could drop below 10...

Page 9: ...which is in a separate room from the combustion appliance s should also contain an alarm located in accordance with Figure 3 Choosing locations in caravans and boats It is not always possible to find...

Page 10: ...m press and hold the test hush button The unit will respond with one of the following status conditions 1 The Green LED on the CO alarm blinks and the horn sounds to indicate the unit is powered and o...

Page 11: ...blue Family members including pets exhibit ing the flu like symptoms of CO poison ing described above If any of these signs are present get the appliance checked out by an expert before further use If...

Page 12: ...PLACE UNIT BY date has been reached Check the label on the side of the alarm CO alarms are not a substitute for life in surance House holders are responsible for their own insurance The CO alarm warns...

Page 13: ...it is possible to further secure or tamperproof the alarm by using a No 2 or No 4 2 to 3mm diameter not supplied self tapping screw 6 to 8mm long to firmly lock the alarm and its mounting plate togeth...

Page 14: ...ate Wait 15 s before testing again by pushing the test hush button Check the age of the alarm see the replace by label on the unit The CO alarm beeps when I press the test hush button but the Visit re...

Page 15: ...n Group AB S dra L ngebergsgatan 30 436 32 Askim Sweden Phone 46 31 68 28 20 E mail info bellman com bellman com Revision BE1555_012MAN005 Date of issue 2020 05 18 TM and 2020 Bellman Symfon AB All ri...