52
Bell
fi res
Installation instructions
0.1"
(2 mm)
Fix the mantle iron to the rear wall with the bar set. Place the draw bars at an angle of
about 60˚ (between the appliance and the wall). Level the mantle iron with the tension
sleeves.
Ensure that the height between the mantle
Keep a clearance of 0.1" (2 mm) between
iron and the underside of the glass is the
the mantle iron and the top of the side
same at left, middle and right.
panels. The side panels should always be
easily removable. Check that the mantle
iron is at right angles to the side panels,
both left and right.
Put ceramic felt on the top of the mantle iron, before laying bricks or using other non-
fl ammable structural materials.
BUILDING IN / HANGING OF THE APPLIANCE