background image

72

Bell

fi res

English

Installation instructions 

4.2  HORIZON BELL XL 3   HIDDEN DOOR

 

Dismantling of the glass:

-  Horizon Bell XL 3 Hidden Door.

 -  Use the hook to pull the frame at the top forward and hold the frame fi rmly.

 -  Use the hook supplied for opening the  
   frame (including glass). 

Summary of Contents for Horizon Bell XL 3

Page 1: ...h closed combustion system This document is an essential part of your gas fire Read it carefully before installation and maintenance of the gas fire and keep it in a safe place Bellfires wishes you ma...

Page 2: ......

Page 3: ...3 Bellfires English Installation instructions BELLFIRES GAS FIRE WITH CLOSED COMBUSTION SYSTEM Horizon Bell XL 3 HBXL3...

Page 4: ...4 Bellfires English Installation instructions...

Page 5: ...3 FAULTS 68 4 DISMANTLING ASSEMBLING OF THE GLASS 69 5 ELECTRICAL DIAGRAM 75 6 DIMENSIONS 76 7 TECHNICAL DETAILS REGULATIONS 81 8 REPLACEMENT PARTS LIST 83 9 DISPOSAL OF PACKAGING AND APPLIANCE 85 Th...

Page 6: ...6 Bellfires English Installation instructions...

Page 7: ...gases and supply of combustion air It is possible to install the gas fire with either a wall or roof outlet The roof connection must be carried out using the concentric flue system 100 mm 150 mm The...

Page 8: ...staller first If the chimney was previously used for a wood or coal fire then it should be cleaned by an expert 1 2 CONCENTRIC FLUE SYSTEMS 100 MM 150 MM AND 130 MM 200 MM Bellfires Muelink Grol syste...

Page 9: ...872 2x Convection exit grid white 145 x 145 mm 309730 2x Collar adaptor 125 mm 304040 4x Hose clamp 125 mm 329874 Set carrying brackets 2 pieces 3 Bellfires M G concentric flue system See component su...

Page 10: ...t for correct operation Roof mounted outlet Figure 1 Roof mounted outlet This must be positioned at least 0 5 m from the roof edge the apex of the roof can be disregarded Wall mounted outlet Figure 2...

Page 11: ...ing an occupied room a toilet or a bathroom B A heating air supply when the supply flows through an occupied room C A window that can be opened and that is near an occupied room a toilet or a bathroom...

Page 12: ...all 2 m if the distance from the facing wall is less the criteria detailed for On a wall general apply Enquire at your local gas company for the regulations relating to outlets positioned opposite eac...

Page 13: ...uter walls approx 150 C no flammable materials may be located or used in the vicinity of the flue system The complete flue system must therefore be sleeved with a heat resistant material after assembl...

Page 14: ...RIGID CONCENTRIC FLUE 100 mm 150 mm SYSTEM CONNECTION POSSIBILITIES Appliance Concentric flue connection 100 150 mm or 130 200 mm Item descriptions see 1 6 2 Assemble restriction plate Appliance Dist...

Page 15: ...LUDE THE LENGTH OF THE ROOF OR WALL TERMINATION 16 23 Y2 X 10 11 12 13 14 15 Y1 4 1 28 23 23 17 24 100 Item descriptions see 1 6 2 Assemble restriction plate Appliance Distance Y1 Distance X Distance...

Page 16: ...26 29 7 5 29 30 10 11 12 13 Y Item descriptions see 1 6 2 Assemble restriction plate Appliance Distance Y Concentric Concentric min max connection connection on appliance is on appliance is 100 150 mm...

Page 17: ...least 2 to 1 ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Y2 Y1 10 11 12 13 45 X Y3 32 18 30 29 5 7 29 26 25 23 28 4 1 100 Item descriptions see 1 6 2 Assemble restriction plate Appli...

Page 18: ...SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Y 7 6 8 18 32 31 29 30 29 26 29 27 28 29 4 1 100 Item descriptions see 1 6 2 Assemble restriction plate Appliance Distance Y Concentric Concen...

Page 19: ...ards is always at least 2 to 1 ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Y3 Y2 Y1 X 45 6 8 7 31 29 32 18 30 29 26 29 27 28 29 4 1 100 Item descriptions see 1 6 2 Assemble restrictio...

Page 20: ...triction plate Appliance Distance Y Distance X Concentric connection on min max min max appliance is 130 200 mm 2 0 3 0 m 0 0 6 m Horizon Bell XL 3 3 0 4 0 m 0 1 6 m Appliance Concentric flue connecti...

Page 21: ...4 110 111 113 0 16 m Appliance Concentric flue connection 130 200 mm Assemble restriction plate Appliance Distance Y Distance X Concentric connection on min max min max appliance is 130 200 mm 0 5 1 0...

Page 22: ...00 mm Assemble restriction plate Appliance Distance Y Distance X Concentric connection on min max min max appliance is 130 200 mm 0 5 1 0 m 0 1 6 m Horizon Bell XL 3 1 0 3 0 m 1 6 4 6 m Item descripti...

Page 23: ...X2 Concentric connection on min max min max min max min max appliance is 130 200 mm 0 0 5 m 0 0 5 m 0 5 1 0 m 0 0 6 m Horizon 0 5 1 0 m 0 0 5 m 0 0 5 m 0 0 6 m Bell XL 3 1 0 3 0 m 0 1 0 m 0 5 2 0 m 0...

Page 24: ...istance X Concentric connection on min max min max appliance is 130 200 mm 0 0 5 m 0 0 6 m Horizon Bell XL 3 0 5 3 0 m 0 3 6 m 1 0 3 0 m 3 6 8 6 m Item descriptions see 1 6 2 4 128 1 Y X 119 114 110 1...

Page 25: ...ipe L 500 mm incl and Twin wall balanced flue elbow 90 incl and BELLFIRES ART ORDER NO 302289 302290 302291 302292 302297 Color Application RVS antr RIGID FLEX l l l l l l l l l l FIG NO DESCRIPTION 1...

Page 26: ...oof flashing for existing chimney or flat roof Horizontal wall termination kit L 600 mm horizontally adjustable incl and one set of wall spacer plates Stainless steel locking band 150 mm quick fasteni...

Page 27: ...nce 150 mm flex Stainless steel locking band 150 mm For adapter 150 appliance 150 mm flex Screw fastening Stainless steel screws 3 5 mm x 9 5 mm For securing the flexible concentric flue Minimum 3 scr...

Page 28: ...ES ART ORDER NO 302302 302303 321948 l l l l l l Color Application RVS antr RIGID FLEX Color RVS Stainless steel self colour polished antr Anthracite colour lacquer matt Adjustable roof flashing for a...

Page 29: ...mm incl and Twin wall balanced flue pipe L 1000 mm incl and Adjustable length twin wall balanced flue pipe L 500 mm incl and Twin wall balanced flue elbow 90 incl and Twin wall balanced flue elbow 45...

Page 30: ...ainless steel adapter piece 200 from fire to flexible 198 mm external rigid x 198 mm internal flex appliance 200 mm flex Stainless steel locking band 200 mm For adapter 200 appliance 200 mm flex Screw...

Page 31: ...e pipe L 450 mm Twin wall balanced flue pipe L 950 mm Telescopic twin wall balanced flue pipe L min 390 mm max 640 mm Twin wall balanced flue elbow 90 Twin wall balanced flue elbow 45 POUJOULAT ART OR...

Page 32: ...it L 140 mm Roof flashing suitable for a brick roof with a roof pitch of 15 30 Roof flashing suitable for a tiled roof with a roof pitch of 15 30 Roof flashing suitable for a brick roof with a roof pi...

Page 33: ...ventilation grooves Set of ceiling finishing plates Fire stops suitable for a roof pitch of 0 10 Set of ceiling finishing plates Fire stops suitable for a roof pitch of 10 30 Set of ceiling finishing...

Page 34: ...150 mm Adapter Bellfires 100 150 mm Poujoulat PGI 100 150 mm Appliance 100 150 Poujoulat PGI 100 150 Adapter Bellfires 130 200 mm Poujoulat PGI 100 150 mm Appliance 130 200 Poujoulat PGI 100 150 Conce...

Page 35: ...7130421 AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC FLUE SYSTEM 130 mm 200 mm DESCRIPTION Twin wall balanced flue pipe L 250 mm Twin wall balanced flue pipe L 450 mm Twin wall balanced flue...

Page 36: ...Ceiling wall plate with spacers and ventilation grooves Set of ceiling finishing plates Fire stops suitable for a roof pitch of 0 10 Set of ceiling finishing plates Fire stops suitable for a roof pitc...

Page 37: ...N Concentric pipe with inspection opening L 250 mm Roof support universal 200 mm Floor support universal 200 mm Adapter Bellfires 130 200 mm Poujoulat PGI 130 200 mm Appliance 130 200 Poujoulat PGI 13...

Page 38: ...th 100 150 mm concentric connection Twin wall balanced flue pipe L 250 mm Twin wall balanced flue pipe L 500 mm Twin wall balanced flue pipe L 1000 mm Telescopic twin wall balanced flue pipe L min 60...

Page 39: ...150 mm Adjustable roof flashing Roof pitch 20 45 with lead flashing Roof flashing plate for roof pitch 5 30 Roof flashing for existing chimney or flat roof Roof flashing Aluminium for existing chimne...

Page 40: ...Locking band quick fastening Cover band screw fastening Wall strap adjustable Fitting bracket Set of ceiling finishing plates Fire stops Centring plates Roof support Renovation set Top of renovation...

Page 41: ...band screw fastening Concentric pipe with inspection panel L 250 mm Concentric pipe with gauging orifice L 150 mm 90 concentric bend with inspection panel Rosette smooth 150 mm Wall plate large 150 mm...

Page 42: ...E SYSTEM 130 mm 200 mm FIG NO 10 11 12 14 DESCRIPTION Adapter for Bellfires appliances with 130 200 mm concentric connection Twin wall balanced flue pipe L 250 mm Twin wall balanced flue pipe L 500 mm...

Page 43: ...Twin wall balanced flue elbow 30 Twin wall balanced flue elbow 15 Vertical roof termination kit L 375 mm incl Storm collar 150 mm Adjustable roof flashing Roof pitch 20 45 with lead flashing Roof flas...

Page 44: ...luminium for existing chimney or flat roof Horizontal wall termination kit L 475 mm horizontally adjustable incl Locking band quick fastening Cover band screw fastening Wall strap adjustable Fitting b...

Page 45: ...TION Roof support Renovation set Top of renovation set Bottom renovation set Locking band screw fastening Concentric pipe with inspection panel L 250 mm Concentric pipe with gauging orifice L 150 mm O...

Page 46: ...nces have been approved in combination with the components of the concentric flue systems listed in this instruction book according to the European CE norm for gas appliances and may therefore be used...

Page 47: ...maximum of 50 cm from the left or right hand side of the appliance 1 6 5 Convection package connections When fitting a convection package convection casing and convection set 1x or 2x consideration sh...

Page 48: ...he appliance to allow for expansion of the appliance during operation Do not insulate the appliance Only the top and sides may be fitted with a strip of white loose insulation wool heat resistant to 1...

Page 49: ...1 Inlet opening appliance convection air 2 Inlet opening grate chimney breast convection air 3 Natural convection in the chimney breast 4 Outlet opening grate chimney breast natural convection air 5 O...

Page 50: ...package 1 Inlet opening appliance convection air 2 Inlet opening grate chimney breast convection air 3 Natural convection in the chimney breast 4 Outlet opening grate chimney breast convection air 2x...

Page 51: ...f the floor of the combustion chamber The floor of the combustion chamber can be reached after the window and the grill around the burner have been removed see chapter 4 Using an Allenkey no 5 the app...

Page 52: ...the gas regulating block and the receiver assembly are fitted Move the appliance until it is 5 cm from the rear wall and ensure it is level Place the nonflammable insulation plate min 12 mm between th...

Page 53: ...cm from the appliance Connect the supplied 8 12 4 mm stainless steel flexible gas pipe on one side under the burner plate with the compression coupling there The connections for the main burner 8 mm s...

Page 54: ...lating block and receiver in operating unit 1 Gas regulating block 2 Gas supply connection 3 8 12 mm insertion 3 Burner piping connection 8 mm insertion 4 Thermocouple connection M 10x1 mm insertion 5...

Page 55: ...be fitted Figure 20 Gas regulating block Remote control Side inlet Side outlet Bottom Outlet Bottom Inlet Inlet Pressure Tap Outlet Pressure Tap Thermo Unit Connection Minimum Rate Adjustment Screw M...

Page 56: ...regulating block in operating unit The photo below shows how the piping for a hand control gas regulating block must be fitted Motor knob Microswitch Operating Knob Remote control Hand control Connect...

Page 57: ...e of minimum 50 mm During subsequent installation of the operating unit protect the gas regulating block and piping against encasement by cement etc Important Cement and chalk can damage the piping an...

Page 58: ...th Ceramic log set embers Marble pebbles white small white marble stones Marble pebbles grey small grey marble stones Important Carefully place the chips of wood embers vermiculite granules log set or...

Page 59: ...log set chips of wood embers vermiculite granules 1 Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings 2 Remove the embers carefully from...

Page 60: ...granules must not be placed next to the pilot light burner Important make sure that all burner openings remain free Burner orifices which are not open could lead to a dangerous situation 4 Place the l...

Page 61: ...61 Bellfires English Installation instructions Logs Log no Log no Log no Log no Log no Log no Log no Log no...

Page 62: ...the pilot light burner Embers must not be placed next to the pilot light burner Keep the burner orifices unblocked Figure 22 Log set Horizon Bell XL 3 Position natural gas burner Keep the burner orifi...

Page 63: ...e burner openings 2 Spread the pebbles over the whole burner bed burner and grid around the burner Make sure that the pilot light remains free Horizon Bell XL 3 see figure 25 Figure 24 Marble pebbles...

Page 64: ...y a proper ignition of the main burner is ensured Once the logs marble pebbles have been positioned replace the glass in the appliance following the instructions in chapter 4 DISMANTLING ASSEMBLING OF...

Page 65: ...um efficiency flame effect and combustion Mounting an incorrect flue gas restriction plate can result in damage to the gas fire Figure 26 Positioning restriction plate Note In order to be able to fit...

Page 66: ...ld be short and blue yellow in colour These flames should gradually increase in height and become more yellow When all flames are yellow the gas fire has reached the correct temperature THE GAS FIRE I...

Page 67: ...bbles on and around the main burner according to the installation directions in this instruction booklet Do not place any embers vermiculite granules logs or pebbles against the pilot light burner Mak...

Page 68: ...Dirty electrical contacts in the thermo electrical system for example the thermocouple connection Batteries in receiver or remote control are flat 3 2 SAFETY MEASURES IN THE APPLIANCE 3 2 1 Thermo ele...

Page 69: ...of the glass Horizon Bell XL 3 Use the hook supplied see photo for Floating Frame opening the frame and the glass With the hook pull the thin metal spring strips on the top left and right from the stu...

Page 70: ...Bellfires English Installation instructions Detail of the stud right Place paperboard on the chimney breast under the frame This helps prevent damage stud right Dismantle the safety strip from the fra...

Page 71: ...ont Check whether the frame is placed in the middle of the front Check whether the safety strip is securely fastened to the top of the frame middle The glass frame must fit tightly all round to the ed...

Page 72: ...structions 4 2 HORIZON BELL XL 3 HIDDEN DOOR Dismantling of the glass Horizon Bell XL 3 Hidden Door Use the hook to pull the frame at the top forward and hold the frame firmly Use the hook supplied fo...

Page 73: ...e hook pull the thin metal spring strips on the top left and right from the studs on the frame Note When loosening the frame and after it has been loosened support it with your hand to prevent it fall...

Page 74: ...the glass The assembly of the glass takes place in reverse order Important Check whether the frame is properly positioned underneath in the 2 holes of the front Check whether the frame is placed in t...

Page 75: ...O I Switch RECEIVER Battery Compartment panel 4 AA Batteries cable 2 cable 1 red black SPARK SPARK SW TC SW TC GR SW MA MO Pilot ON OFF Switch Thermocurrent interrupter Block red Button Reset Motor k...

Page 76: ...76 Bellfires English Installation instructions 6 DIMENSIONS 6 1 HORIZON BELL XL 3 6 1 1 HORIZON BELL XL 3 Hidden Door...

Page 77: ...77 Bellfires English Installation instructions 6 1 2 HORIZON BELL XL 3 Floating Frame...

Page 78: ...n instructions 6 2 HORIZON BELL XL 3 Fitted with the options Convection casing High adjustable feet 6 2 1 HORIZON BELL XL 3 Hidden Door With the high adjustable feet option the appliance can be instal...

Page 79: ...79 Bellfires English Installation instructions 6 2 2 HORIZON BELL XL 3 Floating Frame With the high adjustable feet option the appliance can be installed till 350 mm above the floor...

Page 80: ...80 Bellfires English Installation instructions OPERATING UNIT...

Page 81: ...7 kW 9 2 10 6 kW Efficiency class 1 85 1 85 NOx class 5 5 Gas rate max 1 33 m3 s hr Butane G30 1020 gr hr Propane G31 860 gr hr Supply pressure 20 0 mbar Butane G30 37 0 mbar Propane G31 37 0 mbar Bu...

Page 82: ...132 kg Including all options 155 kg 155 kg When the appliance has reached its thermal equilibrium Burner at maximum Appliance is cold Flue gas exhaust and combustion air supply Roof mounted outlet Con...

Page 83: ...0 Switch with short length of cable to thermocouple interrupter and long length of cable tc L 500 mm to receiver 15 326287 Hand held transmitter Display screen Temperature and two programmes 16 326288...

Page 84: ...bles set white set grey Set Log no Art no A 325291 Horizon Bell XL 3 Chips of Embers with Vermiculite no 4 wood set Glow effect black Anthracite fi ltered 1 331357 2x 2 331358 2x 3 331359 1x 4 331360...

Page 85: ...clude Cardboard Wood Plastic Paper Such materials must be disposed of responsibly in line with local regulations Batteries should be disposed of as chemical waste Batteries must be disposed of respons...

Page 86: ...86 Bellfires English Installation instructions...

Page 87: ......

Page 88: ...02 011212 330312 Your Bellfires dealer...

Reviews: