66
Bell
fi res
English
Installation instructions
The following restriction plates are supplied:
1.7.7 Checking the appliance following installation
After installation, visually check the gas fl ame. When the fi re is ignited, the fl ames
should be short and blue/yellow in colour. These fl ames should gradually increase in
height and become more yellow. When all fl ames are yellow, the gas fi re has reached
the correct temperature.
THE GAS FIRE IS NOW READY FOR USE
%
[
Concentric fl ue connection appliance
[Ø130 - 200 mm]
[Ø100 - 150 mm]
Restriction plate:
Horizontal wall outlet
Roof-mounted outlet
Width:
-
B = 30 mm
Width:
B = 40 mm
B = 40 mm
Width:
B = 50 mm
B = 50 mm
Width:
B = 65 mm
B = 65 mm
Width:
B = 80 mm
-