Bellfires DERBY LARGE 3 CF - LF Instructions For Use & Manual Daily Maintenance Download Page 14

14

Bell

fi res

English

Instructions for use

Set the current time 

• 

The time display will fl ash after either: 

  a  installing the battery or
  b  simultaneously pressing the     (large fl ame) and   
       (small fl ame).

•  While the screen is fl ashing, you can adjust the time. 
•  Press     (large fl ame) to set the hour and    (small fl ame) 
  to set the minute.
•  Wait or press 

OFF

 to return to 

        

mode.

 

 

 

 

 

Set the display - °C/24 hour or °F/12 hour Clock setting

•  Connect the batteries. By simultaneously pressing 

OFF

 and             

         (small fl ame), can be  switched from °F (and 12 hour clock) 

to °C (and 24 hour clock), or vice versa.

•  The display will automatically return to 

         

mode after some 

time, but you may immediately return to          mode by 

  pressing the 

OFF

 button.

 

 

 

Important:   Setting up signal code before using the appliance for the fi rst time.

Before the appliance can be used, the receiver must fi rst learn the hand-held 
transmitter’s signal code.

• 

Press the “

RESET

” 

button

 on the receiver, and keep this pressed until 2 audio signals  

  are heard. See fi gure 3.
  Release the “

RESET

” 

button

 after the second (somewhat longer) audio signal.

• 

Press, within 20 seconds, the     (small fl ame) button on the hand-held transmitter,  

  until 2 short signals are heard. 

The signal code has now been set up on the receiver

.  

  If,  however, a single long sound is heard, this means that setting the signal code has  
  failed or that the wiring has been connected incorrectly.

You only need to set up the signal code once. It is not necessary when changing the 
batteries of the hand-held transmitter or receiver.

 

Summary of Contents for DERBY LARGE 3 CF - LF

Page 1: ...Gas fire with closed combustion system Bellfires wishes you many cosy evenings with your new Bellfires gas fire This document is an essential part of your gas fire Read it carefully before use of the...

Page 2: ......

Page 3: ...3 Bellfires English Instructions for use BELLFIRES GAS FIRE WITH CLOSED COMBUSTION SYSTEM Derby Large 3 CF Centre Fire DYL3 CF Derby Large 3 LF Line Fire DYL3 LF...

Page 4: ...4 Bellfires English Instructions for use...

Page 5: ...5 Bellfires English Instructions for use CONTENTS Page 1 WARRANTY TERMS 7 2 INSTRUCTIONS FOR USE 9 3 USING THE APPLIANCE FOR THE FIRST TIME 25 4 DAILY MAINTENANCE 26 5 ANNUAL MAINTENANCE 27...

Page 6: ...6 Bellfires English Instructions for use...

Page 7: ...plicable legal provisions Article 2 Warranty conditions 2 1 Should you wish to claim under the warranty please contact your Bellfires dealer 2 2 Complaints should be reported as quickly as possible af...

Page 8: ...ass cord thermocouple and the interior of the combustion chamber a similar guarantee is given until after the first burning Article 6 Liability 6 1 A claim granted by Interfocos B V under this warrant...

Page 9: ...2 1 Safety Do not place embers vermiculite granules wood logs or pebbles against the pilot light burner Make sure that the pilot flame can burn at all times freely over the main burner Only in this w...

Page 10: ...e at all times that children and other people who are not aware of the operation of the gas appliance are only in the vicinity of the appliance exclusively under supervision Use a fireguard to protect...

Page 11: ...ance is supplied with a Line Fire double burner Both burners ON Only front burner ON Natural gas The above sketches provide an impression of the flame effect This can differ from reality The flame eff...

Page 12: ...ntrol block assembly The receiver and the gas control block are behind the white panel door operating unit next to the appliance Press the door inwards to open this will release the catch and the door...

Page 13: ...mitter is configured in the factory with a unique signal code Figure 2 Display hand held transmitter ON OFF Temperature setting Possibilities of operation Company modes Program Timer setting Temperatu...

Page 14: ...eturn to mode by pressing the OFF button Important Setting up signal code before using the appliance for the first time Before the appliance can be used the receiver must first learn the hand held tra...

Page 15: ...4 Has no function for the appliance 5 Operating night temperature thermostat 6 Timer setting Burner The appliance s entire burner consists of a front burner and a rear burner Burner operation describ...

Page 16: ...y position The appliance will automatically revert to stand by if the batteries in the receiver are fully depleted The pilot light will also be turned off This also applies to the Thermostat and Timer...

Page 17: ...is automatically regulated to the pre set night temperature In order to allow the appliance to regulate the temperature at night the night temperature must be set to at least 5 C If the setting is lo...

Page 18: ...ation by pressing the SET button briefly Press the SET button until P1 ON start heating period P1 and the time appear in the display The time indication flashes Set the time for the beginning of the f...

Page 19: ...ill automatically rise to the maximum position Important If the pilot flame goes out for any reason wait for 5 minutes before attempting to re light it If the pilot light does not ignite after 3 ignit...

Page 20: ...flame height Extinguishing the fire After ignition the burner automatically sets the flames to the maximum height Press button small flame to lower the flames and to turn off the burner Extinguishing...

Page 21: ...to the high position Pressing the large flame button twice automatically increases the flames to the high position This is indicated by HI on the display Important If you turn on the burner by pressi...

Page 22: ...ery cover Instructions for turning the rear burner on and off After igniting the pilot light and burner the front burner and rear burner are both ON The AUX symbol on the hand held transmitter s displ...

Page 23: ...ature setting is reduced to 3 If the receiver s batteries are depleted the rear burner remains in the last chosen setting IN or OUT During normal use the rear burner will be automatically turned ON if...

Page 24: ...ever 1 Hand held transmitter The battery symbol indicates this in the display Battery fully charged Battery empty 2 Receiver 3x short audio signal audible when the motor knob operates 1 Hand held tran...

Page 25: ...may result in an unpleasant smell This is harmless however Operating the gas fire at full capacity for a few hours while ventilating the room will eliminate the smell After using your gas fire for th...

Page 26: ...t impossible to clean Careful with glass cleaner Make sure that no glass cleaner liquid flows in the sealing of the inside of the glass pane at the bottom of the door Spray each time a little glass cl...

Page 27: ...e complete concentric flue system where possible and the outlet are cleaned and inspected annually by a recognised fitter gas specialist The safe operation of the appliance will thus remain guaranteed...

Page 28: ...01 011113 335611 Your Bellfires dealer...