86

Bell

fi res

English

Installation instructions 

Model      

 

: VIEW BELL SMALL 3  LF  (Line Fire)

Gas         

 

: NATURAL GAS 

: BUTANE / PROPANE

Country   

 

GB; Great Britain/IE; Ireland

  

GB; Great Britain/IE; Ireland

Batteries remote control
- Receiver   

: 4x 1.5V AA   

: 4x 1.5V AA

- Hand-transmitter 

: 1x 9V block   

: 1x 9V block

Weight:
- Basis model: Hidden Door 

: 84 kg 

 

: 84 kg

- Model:  Hidden Door with 10 cm 

: 99 kg 

 

: 99 kg

            frame and mantle iron
-  Option:  Convection package 

: 11 kg 

 

: 11 kg

(*)  :  Both burners at maximum. Appliance is on temperature.
(**)  :   Both burners at maximum. Appliance is cold.
(***) :   Both burners at minimum.

Flue gas exhaust and combustion air supply:
Roof-mounted outlet  :   Concentric fl ue system Ø100 mm - Ø150 mm. Rigid and/or fl exible.
Horizontal wall outlet  :   Concentric fl ue system Ø130 mm - Ø200 mm. Rigid.
 

     

  With wall outlet, depending on the fl ue confi guration; Ø100 mm - Ø150 mm or

 

     

  Ø130 mm - Ø200 mm.

Heat changing surface: Entire front of the appliance.

Summary of Contents for CORNER BELL XXL 3 L CF

Page 1: ...with closed combustion system This document is an essential part of your gas fire Read it carefully before installation and maintenance of the gas fire and keep it in a safe place Bellfires wishes you...

Page 2: ......

Page 3: ...3 Bellfires English Installation instructions BELLFIRES GAS FIRE WITH CLOSED COMBUSTION SYSTEM View Bell Small 3 CF Centre Fire VWBS3 CF View Bell Small 3 LF Line Fire VWBS3 LF...

Page 4: ...4 Bellfires English Installation instructions...

Page 5: ...AULTS 73 4 DISMANTLING ASSEMBLING OF THE GLASS 74 5 DIAGRAM ELECTRICITY AND GAS 79 6 DIMENSIONS 80 7 TECHNICAL DETAILS REGULATIONS 83 8 REPLACEMENT PARTS LIST 87 9 DISPOSAL OF PACKAGING AND APPLIANCE...

Page 6: ...6 Bellfires English Installation instructions...

Page 7: ...or 130 mm 200 mm concentric connection for extracting the flue gases and supply of combustion air It is possible to install the gas fire with either a wall or roof outlet The roof connection must be...

Page 8: ...op Metaloterm US system The gas fire in combination with the concentric flue system 100 mm 150 mm and or 130 mm 200 mm rigid and or flexible for the brands Bellfires Muelink Grol system Poujoulat PGI...

Page 9: ...ES The following options and accessories can be supplied by your dealer Part no Accessorie 312829 Convection set General for convection air extraction 302188 1x Flexible aluminium pipe 125 mm L 3 m ma...

Page 10: ...t for correct operation Roof mounted outlet Figure 1 Roof mounted outlet This must be positioned at least 0 5 m from the roof edge the apex of the roof can be disregarded Wall mounted outlet Figure 2...

Page 11: ...ing an occupied room a toilet or a bathroom B A heating air supply when the supply flows through an occupied room C A window that can be opened and that is near an occupied room a toilet or a bathroom...

Page 12: ...all 2 m if the distance from the facing wall is less the criteria detailed for On a wall general apply Enquire at your local gas company for the regulations relating to outlets positioned opposite eac...

Page 13: ...the outer walls approx 150 C no flammable materials may be located or used in the vicinity of the flue system The complete flue system must therefore be sleeved with a heat resistant material after a...

Page 14: ...RIGID CONCENTRIC FLUE 100 mm 150 mm SYSTEM CONNECTION POSSIBILITIES Appliance Concentric flue connection 100 150 mm or 130 200 mm Item descriptions see 1 6 2 Assemble restriction plate Appliance Dist...

Page 15: ...LUDE THE LENGTH OF THE ROOF OR WALL TERMINATION 16 23 Y2 X 10 11 12 13 14 15 Y1 4 1 28 23 23 17 24 100 Item descriptions see 1 6 2 Assemble restriction plate Appliance Distance Y1 Distance X Distance...

Page 16: ...26 29 7 5 29 30 10 11 12 13 Y Item descriptions see 1 6 2 Assemble restriction plate Appliance Distance Y Concentric Concentric min max connection connection on appliance is on appliance is 100 150 mm...

Page 17: ...least 2 to 1 ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Y2 Y1 10 11 12 13 45 X Y3 32 18 30 29 5 7 29 26 25 23 28 4 1 100 Item descriptions see 1 6 2 Assemble restriction plate Appli...

Page 18: ...SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Y 7 6 8 18 32 31 29 30 29 26 29 27 28 29 4 1 100 Item descriptions see 1 6 2 Assemble restriction plate Appliance Distance Y Concentric Concen...

Page 19: ...ards is always at least 2 to 1 ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Y3 Y2 Y1 X 45 6 8 7 31 29 32 18 30 29 26 29 27 28 29 4 1 100 Item descriptions see 1 6 2 Assemble restrictio...

Page 20: ...ure 10 Horizontal wall termination Item descriptions see 1 6 2 Wall Termination Position 100 4 28 1 Y X 19 14 10 11 13 0 16 m Appliance Concentric flue connection 100 150 mm or 130 200 mm Assemble res...

Page 21: ...4 110 111 113 0 16 m Appliance Concentric flue connection 130 200 mm Assemble restriction plate Appliance Distance Y Distance X Concentric connection on min max min max appliance is 130 200 mm 0 5 1 0...

Page 22: ...200 mm Assemble restriction plate Appliance Distance Y Distance X Concentric connection on min max min max appliance is 130 200 mm 0 5 1 0 m 0 3 6 m View Bell Small 3 1 0 3 0 m 0 8 6 m Item descriptio...

Page 23: ...X2 Concentric connection on min max min max min max min max appliance is 130 200 mm 0 0 5 m 0 0 5 m 0 5 1 0 m 0 0 6 m View Bell 0 5 1 0 m 0 0 5 m 0 0 5 m 0 0 6 m Small 3 1 0 3 0 m 0 1 0 m 0 5 2 0 m 0...

Page 24: ...119 114 110 111 113 0 25 m 123 Wall Termination Position Appliance Concentric flue connection 130 200 mm RIGID CONCENTRIC FLUE 130 mm 200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet 130 m...

Page 25: ...in at a maximum of 50 cm from the left or right hand side of the appliance 1 6 5 Convection package connections When fitting a convection package convection casing and convection set 1x or 2x consider...

Page 26: ...Ventilate the fireplace by allowing vents above and below the fireplace During installation of the gas fire a clearance of 3 mm should be maintained on all sides of the appliance to allow for expansio...

Page 27: ...ening appliance convection air 2 Inlet opening grate chimney breast convection air 3 Natural convection in the chimney breast 4 Outlet opening grate chimney breast natural convection air 5 Outlet open...

Page 28: ...n package 1 Inlet opening appliance convection air 2 Inlet opening grate chimney breast convection air 3 Natural convection in the chimney breast 4 Outlet opening grate chimney breast convection air 2...

Page 29: ...f the floor of the combustion chamber The floor of the combustion chamber can be reached after the window and the grill around the burner have been removed see chapter 4 Using an Allenkey no 5 the app...

Page 30: ...ating unit built in the gas regulator block and the receiver assembly are fitted Move the appliance until it is 5 cm from the rear wall and ensure it is level Place the nonflammable insulation plate m...

Page 31: ...embled Disconnect the bracket with the gas regulator block and receiver from the appliance Carefully move the bracket with the gas regulator block receiver pipes and cables to the operating unit Mount...

Page 32: ...ression fittings and cable connectors can be temporarily disassembled After mounting carefully reassemble all pipes and cables Check afterwards all compression fittings for leaks and that all electric...

Page 33: ...he front burner Gas connection for gas valve to the rear burner Thermocouple interrupter connection Adjustment Screw Minimum Burner pressure Pilot light connection Figure 21 Gas regulator block Rear P...

Page 34: ...OUT connection yellow Piezo cable connection RESET button AUX Electrical connection for gas valve rear burner TC SW Thermocouple voltage current IN connection red 6 VDC Adapter connection option Conn...

Page 35: ...2 1 Mounting the convection package option The convection package option consists of a convection casing and a convection set The convection set is supplied separately and consists of two flexible alu...

Page 36: ...iance Remove the front of the casing if applicable See Chapter 4 Dismantling Assembling of the glass Decide on positions of the vents grilles above and below the fireplace and if applica ble the hot a...

Page 37: ...ssible Level the mantle iron with the supplied bar set Mantle iron in combination with the 10 cm frame option The mantle iron is screwed on the top panel of the 4 sided 10 cm frame at the factory Do n...

Page 38: ...Check that the mantle iron is at right angles to the side panels both left and right Put ceramic felt on the top of the mantle iron before laying bricks or using other heat resistant structural mater...

Page 39: ...nished you can now fit the frame with the small door to the operating unit After installation in a new fireplace and or applying new cement work the appliance cannot be used for at least four weeks Do...

Page 40: ...pebbles against the pilot light burner For that reason the main burner has a protective pilot light cowl Never remove this cowl Make sure that the pilot flame can burn at all times freely over the ma...

Page 41: ...s 1 Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings 2 Remove the embers carefully from their packaging and spread them evenly over the...

Page 42: ...nules must not be placed next to the pilot light burner Important make sure that all burner openings remain free Burner orifices which are not open could lead to a dangerous situation 4 Place the logs...

Page 43: ...65 Bellfires English Installation instructions Logs Log no u Log no v Log no w Log no x Log no y Log no z Log no Log no...

Page 44: ...on natural gas burner Keep the burner orifices unblocked Figure 25 Log set View Bell Small 3 CF LF Position propane butane burner Keep the burner orifices unblocked Embers must not be placed next to t...

Page 45: ...urner openings 2 Spread the pebbles over the whole burner bed burner and grid around the burner Make sure that the pilot light remains free View Bell Small 3 CF LF see figure 27 Figure 26 Marble pebbl...

Page 46: ...way a proper ignition of the main burner is ensured Once the logs marble pebbles have been positioned replace the glass in the appliance following the instructions in chapter 4 DISMANTLING ASSEMBLING...

Page 47: ...e 28 Positioning restriction plate Important Ensure that the correct flue gas restriction plate is mounted Use of the correct flue gas restriction plate will provide optimum efficiency flame effect an...

Page 48: ...all outlet Roof mounted outlet Width B 30 mm Width B 40 mm B 40 mm Width B 50 mm B 50 mm Width B 65 mm B 65 mm Width B 80 mm 1 7 7 Check overpressure hatches There are two overpressure hatches in the...

Page 49: ...gradually increase in height and become more yellow When all flames are yellow the gas fire has reached the correct temperature THE GAS FIRE IS NOW READY FOR USE Check functioning of overpressure hat...

Page 50: ...vermiculite granules logs set or pebbles on and around the main burner according to the installation directions in this instruction booklet Do not place any embers vermiculite granules logs or pebble...

Page 51: ...Dirty electrical contacts in the thermo electrical system for example the thermocouple connection Batteries in receiver or remote control are flat 3 2 SAFETY MEASURES IN THE APPLIANCE 3 2 1 Thermo ele...

Page 52: ...10 cm frame 4 sided Dismantling of the glass Place paperboard on the chimney breast under the appliance This helps prevent damage View Bell Small 3 Pull the side panel forwards on the long side alongs...

Page 53: ...75 Bellfires English Installation instructions Remove the side panel on the right Remove the bottom panel by pulling it gently to tilt forward and to remove Prevent damage to the side glasses...

Page 54: ...ns Unscrew the strip at the front under the Using a screwdriver slide the strip a glass Screws only need a couple of little to the left turns Remove the strip at the front Unscrew the long strip at th...

Page 55: ...rds at the bottom and slide it a little to one side Lift the glass carefully and pull it Remove the glass by slanting it forward forwards a little at the bottom a little at the bottom and taking it ou...

Page 56: ...anes must fit properly all round the edges of the combustion chamber Check if the fastening strips have been properly mounted all round Check if the compression springs has been replaced in the correc...

Page 57: ...ear burner Pilot light gas pipe Thermocouple interruptor 8 Wire connecting cable Gas pipe Front burner Gas valve Rear burner AC power adapter 230 VAC option Button RESET Receiver with battery compartm...

Page 58: ...80 Bellfires English Installation instructions 6 DIMENSIONS 6 1 VIEW BELL SMALL 3 Hidden Door Fitted with the option Convection casing...

Page 59: ...81 Bellfires English Installation instructions 6 2 VIEW BELL SMALL 3 Hidden Door 10 cm Frame...

Page 60: ...82 Bellfires English Installation instructions OPERATING UNIT...

Page 61: ...fficiency class 1 85 1 85 NOx class 5 5 Gas rate max 0 97 m3 s hr Butane G30 750 gr hr Propane G31 620 gr hr Supply pressure 20 0 mbar Butane G30 37 0 mbar Propane G31 37 0 mbar Burner pressure max Ho...

Page 62: ...n Door with 10 cm 99 kg 99 kg frame and mantle iron Option Convection package 11 kg 11 kg Both burners at maximum Appliance is on temperature Both burners at maximum Appliance is cold Both burners at...

Page 63: ...0 0 mbar Butane G30 37 0 mbar Propane G31 37 0 mbar Burner pressure max Hot 11 2 mbar 29 0 mbar Burner pressure max Cold 10 5 mbar 29 0 mbar Burner pressure min 0 9 mbar 1 0 mbar Primary air inlet bur...

Page 64: ...Door with 10 cm 99 kg 99 kg frame and mantle iron Option Convection package 11 kg 11 kg Both burners at maximum Appliance is on temperature Both burners at maximum Appliance is cold Both burners at m...

Page 65: ...89 Burner injector Natural gas Front no 230 1x 2 30 mm 10 334988 Burner injector Natural gas Rear no 190 1x 1 90 mm 11 301928 Burner injector Butane Propane Front no 130 1x 1 30 mm 12 334992 Burner in...

Page 66: ...322552 Pilot light pipe 4 mm L 1500 mm Flexible Stainless steel 41 325750 Burner pipe 8 mm L 1500 mm Flexible Stainless steel 10 kW front burner 42 325750 Burner pipe 8 mm L 1500 mm Flexible Stainles...

Page 67: ...pebbles set white set grey Set Log no Art no K 331144 View Bell Small 3 1 331357 1x 2 331358 1x 3 331359 4 331360 1x 6 331362 1x 7 331363 1x 8 331364 5 331361 3 pieces xxxxxx 1x Bag 125 gr 301863 2x...

Page 68: ...clude Cardboard Wood Plastic Paper Such materials must be disposed of responsibly in line with local regulations Batteries should be disposed of as chemical waste Batteries must be disposed of respons...

Page 69: ...91 Bellfires English Installation instructions...

Page 70: ...01 010214 335498 Your Bellfires dealer...