Use of the Video Outdoor Panels

            1. STAND-BY: 

The call keys with the name of the residents are permanently backlighted during night. The Red LED 

            blinks permanently.

2. CALL: 

Touch the key corresponding to the name of the family you are looking for. The call is acoustically signaled

with a ding-dong. Each touch of the key reinitiates the call. 

4. 

END OF TALK:

 

- After 1 min. from the call, if the resident does not answer.

                            

- At 10 sec. after the door/gate is opened.

                            

- Immediately, if the resident decides to end the talk without opening the door/gate.

3. TALK: 

If the resident answers, talk is initiated. The maximum duration of the talk is 2 min.

5. ACCESS: 

The door/gate will be open during the time set at the SCU (maximum 10 sec.). Access granting is

acoustically signaled through a confirmation beep sequence.

    

6. RFID CARD ACCESS: 

If you program the RFID cards in the outdoor panel, each resident of the building has

access using the secured RFID card from BELLCOME. Approach the card to the RFID         area marked on the

outdoor panel. The access is signaled acoustically, through a confirmation beep sequence, and visually – the        

symbol blinks white.      

EN

9

At the moment of the delivery from the factory, the 

TL

 video outdoor panels do not have access cards memorized.

In order to have access in the building after installation, it is mandatory to program the RFID cards in the

outdoor panel. 

During programming the installation has to be connected to the grid (110V/230Va.c.) and fully operational.

1.

 Go to the place where the 

SCU

 central unit of the installation is mounted. Long press (3 sec.) the 

PROG

 button on 

the 

SCU

. The Red LED turns on.

2. 

Take the RFID cards to the outdoor panels. To program them, approach every card for one second to the 

RFID        area of the outdoor panel. For each programmed card, the panel issues two short beeps. Repeat this step 

for programming all the RFID cards.

3. 

Go to the place where the 

SCU

 central unit of the installation is mounted. Short press the 

PROG

 button on the 

SCU

The Red LED turns off. The installation returns to normal functioning, successfully ending the programming mode.

                           

Orientable

 video camera

RFID reader. 

RFID tag/card access

Microphone

Fastening

 Torx screw

IR LEDs

(

night lighting

)

 

Touch keys 

for call, 

with the name of the residents

Speaker 

Fastening

 Torx screw

1 Fam.

5 Fam.

2 Fam., 3 Fam. 

Fam 2
Fam 1

Fam 3

Fam 4

Fam 5

Fam 1

29

mm

27

mm

115 mm

145 mm

5

EN

Deleting the RFID Cards from the panel

5.2

EN

This procedure applies when you wish to 

give up access with RFID cards

. During the deletion of the 

RFID cards

the installation has to be connected to the grid (110V/230Va.c.) and fully operational.

1. 

Go to the place where the 

SCU

 central unit of the installation is mounted. Long press (3 sec.) the 

PROG

 button on

the 

SCU

. The Red LED turns on. The installation enters programming mode:

   

         

Not

e

:

 The Red LED can be disabled through jumper JP1 (RED LED) on the board of the keyboard, when the

name labels are added. 

Manual programming of the RFID Card

s

 in the panel/

Adding a new RFID Card in the panel.

5.1

EN

Summary of Contents for PA.1FR02

Page 1: ...1 Fam Video 2 Fam Video 3 Fam Video 5 Fam Video EN 4 Wires VIDEO OUTDOOR PANELS 1 5 Families for TL door phone systems User manual ...

Page 2: ...must be performed byAUTHORIZED PERSONNEL DO NOT power the product at 110 230 Va c DO NOT hit the glass screen with hard objects If the glass screen is broken DO NOT touch the product Protect the products against lime and dust during renovation activities EN 1 0 Contents EN 1 Safety instructions 2 Description of the video outdoor panels 4 Installation of the Video Outdoor Panel 5 Use of the video o...

Page 3: ...24AWG max 50m can also be used 4 Installation of the advanced Video Outdoor Panel VPA EN STEP 1 U C D GND 20 25mm 6mm Vin U C D GND 20 25mm 6mm Vout Wall installation height o 70 175 cm 130 cm 115 cm 160 cm 170cm o 20 o 50 Case aluminum 4 mm chemicallytoughened glass 70º 25º orientable video camera CMOS 1 3 573 H x 597 V 800 TVL video 1 Vpp 75 W PAL IR LEDs 850 nm IR CUTfor night vision 10m TOUCH ...

Page 4: ...te JP1 Signaling of video monitoring RED LED ON Unmount the module and add name labels STEP 3 1 STEP 3 2 Mount back the family name module STEP 2 Mounting on the wall Flush 5 cm 20 cm JP2 Setting of image recording on DVR DVR ON o 70 o 25 o 25 o 25 o 25 o 30 o 70 OFF ON GNV Vout GND C D U OFF ON DVR RED LED OFF ON DVR OFF ON RED LED o 120 o 30 EN 3 ...

Page 5: ... connections in the panel Torx Mounting the outdoor panel on the wall Surface Important For both types of mounting the Torx screws for fastening the outdoor panels on the wall will be very well tightened to prevent the anti theft alarm sensor from setting off 4 1 EN STEP 1 STEP 1 1 U C D GND Vout Vout U C D GND GNV GNV EN 4 ...

Page 6: ...tiple entrances Entrance 2 Entrance 3 Entrance 4 panels 2 3 and 4 will be programmed according to the procedure in Ch 4 6 EN 5 Vout2 GNV GND U VPA address 1 Fam 1 Fam 1 address 1 GONG2 GONG1 DBL1 DBL2 Doorbell U C D GND Vin GONG SCU U PROG BAT 110 230V OUT1 AUX Vcam Vout2 GNV GND U SCU U PROG BAT 110 230V OUT1 AUX Vcam Fam 2 address 2 GONG2 GONG1 DBL1 DBL2 Doorbell U C D GND Vin GONG Fam 1 address...

Page 7: ...Fam 3 the terminal will be programmed with address 2 respectively address 3 See Ch 6 of the user manual for TL audio video terminals Electrical connections diagram for 3 family residences EN 6 4 3 EN U C D GND Vin GONG 2 GONG 1 DBL 1 DBL 2 Doorbell GONG 2 GONG 1 DBL 1 DBL 2 Doorbell U C D GND Vin Fam 3 address 3 Fam 2 address 2 GONG GONG Vout2 GNV GND U SCU U PROG BAT 110 230V OUT1 Vcam OUT2 OUT3 ...

Page 8: ...ces Entrance 2 Entrance 3 Entrance 4 panels 2 3 and 4 will be programmed according to the procedure in Ch 4 6 4 4 EN OUT 4 OUT 2 OUT 3 OUT 1 OUT IN VCB GONG GONG GONG U C D GND Vout Doorbell GONG 2 GONG 1 DBL 1 DBL 2 U C D GND Vin Doorbell Fam 4 address 4 GONG 2 GONG 1 DBL 1 DBL 2 U C D GND Vin Doorbell GONG 2 GONG 1 DBL 1 DBL 2 U C D GND Vin U C D GND Vin Doorbell GONG 2 GONG 1 DBL 1 DBL 2 GONG F...

Page 9: ... Long press the PROG button at SCU 2 Long touch the Fam 1 keyat the VPA2 panel long beep Short touch the Fam 1 key twice Two short beeps confirmation The VPA3 panel with address 3 Long press the PROG button at SCU 3 Long touch the Fam 1 keyat the VPA3 panel long beep Short touch the Fam 1 key three times Three short beeps confirmation The VPA4 panel with address 4 Long press the PROG button at SCU 4...

Page 10: ...be connected to the grid 110V 230Va c and fully operational 1 Go to the place where the SCU central unit of the installation is mounted Long press 3 sec the PROG button on the SCU The Red LED turns on 2 Take the RFID cards to the outdoor panels To program them approach every card for one second to the RFID area of the outdoor panel For each programmed card the panel issues two short beeps Repeat t...

Page 11: ...al blows e Unauthorized interventions to any of the components of the installation f Theft fire natural disasters g Lack of protection of the installation components in case of renovation activities 6 Maintenance of the video outdoor panels 7 Warranty EN EN EN 10 2 To delete the RFID access cards from the memory of the panel Long touch the Fam 1 key until the acoustic confirmation of the panel wit...

Page 12: ...732510 MPI Ciudad de Mexico Mexico ELECTRA is a trademark of ELECTRA Group No 008958332 EUIPO Alicante Spain BELLCOME ELECTRA products are registered as Industrial Models at EUIPO Alicante Spain The products are CE certified Certificate no E307311 ISO 9001 2015 ISO 14001 2015 Certificates no 73 100 4856 73 104 4856 by TÜV HESSEN The products are manufactured under Quality and Environment Management S...

Reviews: