Use of the Video Outdoor Panels
1. STAND-BY:
The call keys with the name of the residents are permanently backlighted during night. The Red LED
blinks permanently.
2. CALL:
Touch the key corresponding to the name of the family you are looking for. The call is acoustically signaled
with a ding-dong. Each touch of the key reinitiates the call.
4.
END OF TALK:
- After 1 min. from the call, if the resident does not answer.
- At 10 sec. after the door/gate is opened.
- Immediately, if the resident decides to end the talk without opening the door/gate.
3. TALK:
If the resident answers, talk is initiated. The maximum duration of the talk is 2 min.
5. ACCESS:
The door/gate will be open during the time set at the SCU (maximum 10 sec.). Access granting is
acoustically signaled through a confirmation beep sequence.
6. RFID CARD ACCESS:
If you program the RFID cards in the outdoor panel, each resident of the building has
access using the secured RFID card from BELLCOME. Approach the card to the RFID area marked on the
outdoor panel. The access is signaled acoustically, through a confirmation beep sequence, and visually – the
symbol blinks white.
EN
9
At the moment of the delivery from the factory, the
TL
video outdoor panels do not have access cards memorized.
In order to have access in the building after installation, it is mandatory to program the RFID cards in the
outdoor panel.
During programming the installation has to be connected to the grid (110V/230Va.c.) and fully operational.
1.
Go to the place where the
SCU
central unit of the installation is mounted. Long press (3 sec.) the
PROG
button on
the
SCU
. The Red LED turns on.
2.
Take the RFID cards to the outdoor panels. To program them, approach every card for one second to the
RFID area of the outdoor panel. For each programmed card, the panel issues two short beeps. Repeat this step
for programming all the RFID cards.
3.
Go to the place where the
SCU
central unit of the installation is mounted. Short press the
PROG
button on the
SCU
.
The Red LED turns off. The installation returns to normal functioning, successfully ending the programming mode.
Orientable
video camera
RFID reader.
RFID tag/card access
Microphone
Fastening
Torx screw
IR LEDs
(
night lighting
)
Touch keys
for call,
with the name of the residents
Speaker
Fastening
Torx screw
1 Fam.
5 Fam.
2 Fam., 3 Fam.
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 1
29
4
mm
27
4
mm
115 mm
145 mm
5
EN
Deleting the RFID Cards from the panel
5.2
EN
This procedure applies when you wish to
give up access with RFID cards
. During the deletion of the
RFID cards
,
the installation has to be connected to the grid (110V/230Va.c.) and fully operational.
1.
Go to the place where the
SCU
central unit of the installation is mounted. Long press (3 sec.) the
PROG
button on
the
SCU
. The Red LED turns on. The installation enters programming mode:
Not
e
:
The Red LED can be disabled through jumper JP1 (RED LED) on the board of the keyboard, when the
name labels are added.
Manual programming of the RFID Card
s
in the panel/
Adding a new RFID Card in the panel.
5.1
EN