background image

Page9

Page10

Instruction of Using Our Products

Precautions

1. The installation should be carried out by a qualified technician and creepage protector 
    should be installed in the place easily to be controlled.
2. The electronic parts should be well grounded, otherwise, the manufacturer will not be 
    liable for any loss or consequences occurred.
3. The load capability of the power supply should be considered during installation, or it 
    affects the normal operation of the product or may lead to accident!
4. For any functions can not be activated through the ways mentioned above, please 
    contact a certified technicians or local dealer.
5. If you don't use the product for a long time, please disconnect the main power supply.
6. Parts containing live parts, except parts supplied with safety extra-low voltage not 
    exceeding 12V, must be inaccessible to a person in the bath.
7. Earthed appliances must be permanently connected to fixed wiring.
8. Parts incorporating electrical components, except remote control devices, must be 
    located or fixed so that they cannot fall into the bath.
9. The appliance should be supplied through a residual current device (RCD) having a 
    rated residual operating current not exceeding 30mA.
10. Make sure that the wire is laid correctly.
11. Make sure that the equipotential connection is done correctly.
12. The means having a contact at least 3.0mm separation in all poles that provide full 
      disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
13. If the supply cord is damaged,it must be replaced by the manufacturer, its service agent 
     or similarly qualified persons in order to avoid a hazard.

Earthing Marking

Equipotential  

Switch Marking 

Function Instruction

1. On/off
    when power-up state, press any key the back lamp of the control panel is semi-light,   
    press (      ) to start the system, the back lamp is full light, all functions are open, the 
    screen issues blue light, and display the current temperature, repress to close all 
    functions.
2. Lamp
    Press (      ) to turn on/off the lamp.
3. Ozone
    Press (      ) to turn on/off the ozone.
4. Air pump
    Press (      ) to turn on/off the air pump.
5. Water pump
    Press (      ) to turn on/off the water pump when it is full of water. 
    When lack of water, press (      ), there water pump will not start and it displays (      ) on 
    the screen. When plenty of water is filled, the pump start and it displays (      ) on the 
    screen.
6. Heater
    Press (      ) to turn on/off the heater when it is full of water. When lack of water, press
   (      ), the heat will not start, it displays (      ) on the screen.  When plenty of water is 
    filled, the pump start and it displays (      ) on the screen.
7. Sound 
    when the system is startup, press (      ) the panel once start FM,the LCD displays 
    current frequency; when the FM is startup, hold down (      ) it will go up to search or 
    memory the channel automatically, press (      ) of the panel, the FM frequency shines, 
    repress (      ) or (      ) to search the channel up or down manually. When the frequency 
    stops shining, press (      ) for the second time, the FM frequency shines, repress (      ) 
    or (      ) the search the channel up and down, the frequency range is 0-19. Press (      ) 
    of the panel, the system changes to CD, it will display

CD

.

8. Adjustment of volume
    When the sound is startup, press (      ) and then press (      ) or (      ) to adjust the 
    volume of the sound, the LCD screen displays 0db-15db. 
9. Automatic lock
    When the system is startup, if there is no operation within 3 minutes, the keys will be 
    locked by the system automatically, hold (      ) for a while then the keys can be unlocked

Summary of Contents for MT-RT1803E

Page 1: ...rance 3 Scale deposit can be wiped off with warm citric acid or vinegar by a soft cloth 4 Don t clean the tub and with hard or coarse material to avoid any scratches 5 Don t clean the tub and with gasoline to avoid any damages 6 It is not recommended to leave water in the tub for a long time or use this tub for washing purpose Pls drain off the water after the bath and dissconnect the power supply...

Page 2: ...essure sugar diabetes should not take a steam shower or bath when feeling sick The kid is suggested to be accompanied by an adult when taking a bath 2 Don t take a bath alone after drinking wine with alcohol or excess sports 3 The water temeperature should be below 45 during shower and the recommended temperature is 30 38 4 Don t take a bath for a long time Recommended time 15 21 5 All the informa...

Page 3: ...d Hot 350mm 400mm 300mm 1800mm 610mm 900mm Installation Process Install 2 water supply holes one for cold and another for hot 1 electrical outlet 1 drain hole diameter 5cm in advance Do as the pic shows Preparations 4 3 5 1 Open the accessory box 1 and take out the faucet as pic shows 2 Remove the screw of inlet faucet 3 Put the inlet faucet into the hole of the bathtub 4 Put the rubber from below...

Page 4: ...n install downcomer 6 Use thread sealing tape to wrap around the drain hole 7 Make the thread sealing tape smooth 8 Fasten the drain tube 9 Put downcomer into the drain hole on the ground 11 Put plug into the drain hole 10 Connect the cold and hot water pipes These 2 pipes are not contained in the package pls prepare by yourself 12 Install pillow Installation Process Installation Process ...

Page 5: ...annel 6 FM CD 7 Unlock 8 Lamp 9 Ozone 10 LCD Display 11 Volume Down 12 Volume 13 On off Run Condition Technology Parameter Load type Rated load voltage Rated load frequency Rated power Others Water pump AC 220V 50HZ 750 W Bubble AC 220V 50HZ 300W Light AC 12V 20W Ozone AC 12V 5W Sound 8 10W Ù Controller 210mm 48mm 45mm l w h Generator 215mm 125mm 60mm l w h Rated voltage AC 220V 240V Rated frequen...

Page 6: ... qualified persons in order to avoid a hazard Earthing Marking Equipotential Switch Marking Function Instruction 1 On off when power up state press any key the back lamp of the control panel is semi light press to start the system the back lamp is full light all functions are open the screen issues blue light and display the current temperature repress to close all functions 2 Lamp Press to turn o...