1 Way Single Door Systems
Cable Requirement
(Refer to diagrams 2a and 2b.)
Cable types (solid core)
0.5 mm
Twisted pair, e.g. BT spec CW1308
1.0 mm
1.0 mm
2
‘Twin & Earth’
Co-ax
75 Ohm, RG59 or equivalent
Video phones
Total Cable Length
Power (+,-)
Other connections
Video Signal
50 m
8 @ 0.5 mm [, -]
75 Ohm Co-ax
100 m
2 @ 1.0 mm
4 @ 0.5 mm
75 Ohm Co-ax
e.g.
A Video phone with a 50 m length requires ; 8 conductors @ 0.5 mm.
Entrance
Connections
No. of Cores
Max
Length
Solid Core
Diameter
Speech unit + Call Button
5 + 75 Ohm Co-ax
50 m
0.5 mm
Lock Release (up to 0.5 A)
2
25 m
100 m
0.5 mm
1.0 mm