1 Way Video Entry System
PD-097 Issue 4
Installation and Operating Manual
Page 9 of 40
Design Considerations
Equipment List
A BS1 one-way bell
issimo
Video Kit comprises the following: -
Model No Description
1 x BS
Colour Videophone
1 x BSP1
Standard panel with a model 61 speech unit and camera.
1 x BSD1 Door controller.
1 x PS4
4A 12V power supply.
1 x 203
Fail-secure lock release
For a vandal resistant panel order a BS1/VR kit.
For a bell
ini
style kit order a BLV1. N.B. bell
ini
systems do not include a 203 lock release.
Options
The following options are available: -
● Extensions model
BS
videophone(s).
● Audio only phones model
BSA
as extensions.
● Additional entrances, each comprising a
BSD1
controller and
BSP1
panel.
(See also power supply requirements).
● Alternate lock releases, fail-safe and fail-secure.
● Timed Trades facility; specify
TRBS
to add another button and a
TS2000-BST
time-
clock. On vandal resistant panels the extra button will be engraved “TRADES”
● Exit button. Model
5077
surface and model
5078
flush versions are available.
● Battery back-up power supply,
Model 840
(12V 4A).
● DDA panels (Contact sales for further information).
Entrance Panel
– Important Note
Careful consideration should be given to the location of the entrance panel to ensure the
best possible lighting conditions for the camera. In general strong back lighting of the
subject (by the sun and sky) should be avoided, as the contrast between foreground and
background may be too great for the camera. The field of view should contain as little of
the sky as possible, particularly if south facing. If a backlit situation is unavoidable,
additional lighting may be necessary to illuminate the caller and avoid a dark outline image
(silhouette). A light coloured or reflective surface around the panel will redirect backlight to
illuminate the caller.
Door Controller
The door controller and power supply should be wall-mounted in a convenient cupboard or
other protected environment with available mains power. Cable length to the entrance
should be less than 50m. The door controller for the second and subsequent entrances
may be situated in the same location, or to meet the 50m requirement may be situated in
another location. Power supplies may be shared between door controllers placed in the
same location, but controllers in separate locations must be separately powered.