Bellcall Digital Door Entry System
PD-083 Issue 3A
Installation and Operating Manual
Page 20 of 46
PSEC – Panel Security Key
The security key is required to gain access to panel programming.
The code is entered then pressing the
call
button, the default is [3434] and it is
recommended that this be changed for security.
This code can contain letters and numbers for added security.
PPRG – Phone Programming Security Key
The phone programming security key is required to gain access to flat number
programming of telephones. The default is [1212] and it is recommended that this be
changed for security.
This code can contain letters and numbers for added security.
RING – Ringing Time/Call Time and Ring Effect
Enter from 0 to 15 as per the table
Setting Ring Time Ring Cadence or Sound Effect
0
5s
1 in 3 – 1 ring every 3 seconds
1
8s
1 in 3 – 1 ring every 3 seconds
2
10s
1 in 3 – 1 ring every 3 seconds
3
15s
1 in 3 – 1 ring every 3 seconds
4
20s
1 in 3 – 1 ring every 3 seconds
5
30s
1 in 3 – 1 ring every 3 seconds
6
40s
1 in 3 – 1 ring every 3 seconds
7
45s
1 in 3 – 1 ring every 3 seconds
8
50s
1 in 3 – 1 ring every 3 seconds
9
60s
1 in 3 – 1 ring every 3 seconds
10
30s
1 in 3 (Reserved For future use)
11
30s
1 in 3 (Reserved For future use)
12
30s
2 in 15 – 2 rings, 15S silence, repeat
13
30s
1 in 15 – 1 ring, 15S silence, repeat
14
30s
1 in 5 – 1 ring every 5 seconds
15
30s*
1 in 3* – 1 ring every 3 seconds
Default setting
TALK – Talking Time/Phone Active
Enter from 0 to 15 as per the table
Setting Talk Time
Setting Talk Time
Setting Talk Time
Setting Talk Time
0
15s
4
60s
8
150s
12
60s
1
20s
5
75s
9
180s
13
60s
2
30s
6
90s
10
60s
14
60s
3
45s
7
120s
11
60s
15
60s*