background image

PD-083 Issue 3A

April 2009

Bell System (Telephones) Ltd.

Bellcall

Digital Door Entry System

Installation & Operation Manual

This manual applies to : -

BCP1 – Version 3

BSD-DIG – Version 2 Build 3 & 4

BSC4-AD – Version 2 Builds 4 to 7

BSSW – Version 2 Build 1

Summary of Contents for Bellcall

Page 1: ...il 2009 Bell System Telephones Ltd Bellcall Digital Door Entry System Installation Operation Manual This manual applies to BCP1 Version 3 BSD DIG Version 2 Build 3 4 BSC4 AD Version 2 Builds 4 to 7 BSSW Version 2 Build 1 ...

Page 2: ...Bellcall Digital Door Entry System PD 083 Issue 3A Installation and Operating Manual Page 2 of 46 ...

Page 3: ...PER SETTINGS 21 BS A AND BC801 PHONE SWITCH SETTINGS 22 BSC4 AD AUDIO ISOLATOR SETTINGS 23 TROUBLESHOOTING 25 QUICK FAULT REFERENCE 25 SPECIFICATIONS 29 DIAGRAM A SYSTEM WIRING BCP1 PANELS 31 DIAGRAM B SYSTEM WIRING BCP VR PANELS 32 DIAGRAM C SYSTEM WIRING BCP VR PANELS 33 DIAGRAM D SYSTEM WIRING BCP VR PANELS 34 DIAGRAM E SYSTEM WIRING BCP VR PANELS 35 DIAGRAM F SYSTEM WIRING BCP VR PANELS 36 DIA...

Page 4: ...ital system is supplied with a dedicated door controller for each entrance the standard unit includes this in the panel assembly The basic system supports 1 phone per address and a number of extension phones consideration must be given to cabling and power supply s for the extra ringing current Multiple entrances can be supported with the addition of one panel and one door controller if vandal res...

Page 5: ...ger systems with BSC4 AD group isolators and possibly BSSW gate switchers It is also feasible that other bellissimo BSD8 or BSD72 controllers may be used in mixed systems to provide small blocks with 1 button per flat panels See Design Considerations for more detail N B The term Flat is used generically to mean Flat House or Office etc Phone Details The BC801 phone is identical in style to our pop...

Page 6: ...g a blank display The reception or Porter Suitcase button calls a phone dedicated to that location The door or Trades button is used to gain direct access either directly or via a code Call sequence When the callers address entered and the call button is pressed at the entrance panel it causes the phone to ring and the red mute lamp to flash The phone will continue to ring for up to 30 seconds or ...

Page 7: ...lat The number of extensions is limited only by power supply and cabling considerations All phones for that flat will ring when called Once a phone is picked up the conversation will only be with that phone Lock Type and Operation The door controller supports both fail secure and fail safe locks including magnetic locks of up to 0 5A rating 1A BSD DIG The lock output is provided by a relay contact...

Page 8: ...all the door controllers and phones can be connected on a single bus and this works for smaller systems However there is a data limitation of 128 items phones or controllers on a single bus and a total cable length limitation of about 1000metres BSC4 AD audio controller This controller performs group isolation and allows both of the above limits to be overcome Each controller can split the phones ...

Page 9: ...xed Audio Video Systems A Bellcall system can be connected to a bellissimo video system where there are shared entrances the BSSW would be the recommended method All wiring carrying video must be installed to the requirements of the relevant bellissimo installation manuals however the Bellcall wiring may be added to any convenient point Do not connect the video signal into the Bellcall wiring Powe...

Page 10: ...r with main colours Orange Green and Brown Also available and acceptable are UTP Category 5e Cat5e UTP Category 6 CAT6 UTP Category 6e CAT6e The exact cable can be chosen from the above on cost and availability grounds STP Shielded Twisted Pair cables are not recommended NOTE Cat5 cable is easily identifiable as the specification is printed on the sheath UTP Patch cable is normally more expensive ...

Page 11: ... 50m 0 5mm dia Phones per branch 1 80m 2 70m 5 50m 10 30m 20 6 3 pairs 20m 0 5mm dia Phones per branch 1 165m 2 140m 5 100m 10 65m 20 8 4 power 2 pairs 40m 0 5mm dia 5 150m 10 125m 20 2 4 2 power 2 pairs 75m 2 1mm2 4 0 5mm dia BCP1 Entrance Panel Connections Connection No of Cores Cable Length Core Size 10m 0 5mm dia Junction Box see diagram 1 6 2 2pairs 40m 2 1mm2 4 0 5mm dia If using a TS2000 Ti...

Page 12: ... the section headed Important Safety Information on page 45 Ensure that Design Considerations on page 8 have been understood Confirm that Cat5 cable or CW1308 has been specified Install the system according to instructions in this section Check set the audio controller BSC4 Ax switch settings Check set each phone dipswitch and or jumper settings Check set the door controller BCP1 or BSD DIG settin...

Page 13: ... both sides Before replacing the Front Cover check that the DipSwitch settings are correct or change as necessary see Page 18 Electric Door Release Both fail secure and fail safe lock releases including magnetic locks use the same terminals To set the lock type refer to the Door Controller Settings When installing lock releases please allow a little movement on the door as operation will be impair...

Page 14: ...anel Programming The default of contacts open when door closed must be selected when this feature is not required Time Clock Sharing In a large system the time clock can be shared between distributed entrances by using one of the Cat5 common wires for the common time clock signal Se the detailed diagram on page 42 Commissioning The many components of the Bellcall Digital system are fitted with hig...

Page 15: ... default 1212 followed by CALL 3 Display says WAIT 4 Pick up Handset to be programmed Display says TALK Panel and handset may talk to each other confirm phone new identity 5 Type new number followed by CALL Display says OK to confirm Program procedure One man operation Prepare a power supply controller and phone connection either in situ or at a convenient location and follow the above procedure o...

Page 16: ...ll enter panel programming for 10S when the panel security code can be read or set Panel Programming To use Panel Programming Mode firstly type the Panel Security Code initially 3434 followed by the call button The display will show the first programmable parameter MODE Press the door button to alternate between the current value of the parameter and the name of the parameter Press the porter butt...

Page 17: ...d whenever the display indicates CODE The Trades mode needs to be set to Code as per the table above The default is 1234 and it is recommended that this is changed for security Letters cannot be used in this code and 4 digits must be used leading 0 is OK PORT Porter Phone Address The porter button is used to call a porter or reception desk or similar The number is that of the called phone The defa...

Page 18: ...n The display will show the first programmable parameter ACOD and then alternating at 1S intervals will be the data and the parameter name Press the door button to step down through the programmable parameters Press the reception button to step up through the programmable parameters The list rolls over bottom to top and vice versa To change a numeric parameter simply type a new 1 4 digit value and...

Page 19: ...e Secr Fail secure lock Requires alternate mechanical means key or thumb turn to open on power failure Safe Fail safe lock Lock opens on power failure CAM2 Second Camera Present No Only 1 camera Yes Second camera present TRAD Door Button Trades Mode None No function pressing the door button is ignored Door Pressing the door button opens the door Code Pressing the door button prompts for the ACOD a...

Page 20: ... as per the table Setting Ring Time Ring Cadence or Sound Effect 0 5s 1 in 3 1 ring every 3 seconds 1 8s 1 in 3 1 ring every 3 seconds 2 10s 1 in 3 1 ring every 3 seconds 3 15s 1 in 3 1 ring every 3 seconds 4 20s 1 in 3 1 ring every 3 seconds 5 30s 1 in 3 1 ring every 3 seconds 6 40s 1 in 3 1 ring every 3 seconds 7 45s 1 in 3 1 ring every 3 seconds 8 50s 1 in 3 1 ring every 3 seconds 9 60s 1 in 3 ...

Page 21: ...hones will continue to ring even though the door controller has closed down If this situation applies then ensure CANC is set to No otherwise the default is Yes BCAL Bellcall Compatibility Mode For use in mixed systems with a BCP1 panel revision V2 0 upwards Switching compatibility mode to Yes changes the number format for addressing a phone and removes the 3 Second overhang of speech when operati...

Page 22: ...On On On 1 hour Off On On Off 2 hours Off On Off On 4 hours Off On Off Off 5 hours Off Off On On 6 hours Off Off On Off 8 hours Off Off Off On 10 hours Off Off Off Off Indefinite Default setting Disabled means pressing the mute button has no effect Indefinite the mute is cancelled by pressing the button again Master Slave Jumper There is a jumper in the BS A phone marked MA for master and EX for s...

Page 23: ...SD72 SW6 Setting Pos Phone 1 Phone 2 Phone 3 Phone 4 0 None None None None 1 1 2 3 4 2 5 6 7 8 3 9 10 11 12 4 13 14 15 16 5 17 18 19 20 6 21 22 23 24 7 25 26 27 28 8 29 30 31 32 9 33 34 35 36 A 37 38 39 40 B 41 42 43 44 C 45 46 47 48 D 49 50 51 52 E 53 54 55 56 F 57 58 59 60 Address Offset SW7 Builds up to 6C SW7 is a 4 bit switch that is used to increase the addressing range For each bit that is ...

Page 24: ...ssing above 6413 For instance by making the jumper add 5000 the BSC4 would be able to address from 1 to 3210 and 5001 to 8210 Phone 1 output Extended Addressing Jumper PROG pins 2 3 Build 7A This jumper adds nn00 to the phone 1 address set using SW6 and SW7 The value nn00 is shown on the build label The jumper is stored on pins 4 5 The use of this jumper precludes the use of Odd Even addressing by...

Page 25: ... the phone is off hook and cannot converse with the panel The system indicates busy when the controller thinks another panel is making a call Entering a flat number and pressing the call pushbutton causes a call to that phone which replies with an acknowledge and starts to ring on receipt of the acknowledge the controller turns on the Status LED Answering the phone by picking up the handset sends ...

Page 26: ...hone too far Not enough power cores Power supply or other fault Phone resetting Indicators lights flash red then green and then go off Power supply intermittent short or overload Lock output short circuit see Lock Problems Green LED does not light on controller Temporarily remove connection to 12V output If the LED now comes on there is a short on the phone cabling 12V input connections are revers...

Page 27: ...o high Broken Audio 1 or 2 wire in the phone cabling Data wiring fault on A or B wires Check for A and B reversed a short A to B a short to ground or power Intermittent or broken wire in Data A or B Phone has reset see power faults Check model 61 is hard against the panel with no gaps Check model 61 speech unit is the right way round and that the microphone hole in the speech unit lines up with th...

Page 28: ...Lock current is too high Power supply is resetting Power supply drop too high cable or distance limits to controller exceeded Maglock or Solenoid bolt not suppressed will cause failures or damage Lock operates from the exit button but not the test button or phone Normally closed switch has been used for exit button Lock release operates all the time or in reverse Check fail safe fail secure select...

Page 29: ...nimum 30V d c maximum Current consumption 20mA idle 67mA ringing 13 8V BSD DIG Door Controller Size 185mm x 230mm x 42mm Supply Voltage 10 8V min 13 8V typical 15V max Current Consumption 80mA idle 500mA max 13 8V Includes display and speech BSSW Gate Switcher Block Isolator Size 185mm x 230mm x 42mm Supply Voltage 10 8V min 13 8V typical 15V max Current Consumption 80mA idle 210mA max 13 8V BSC4 ...

Page 30: ...Power Supply Size 140mm x 60mm x 53mm Output Voltage regulated 13 5V Min 13 8V Nom 14 1V Max Output Current 1A continuous 1 5A peak 5 minutes max Mains Supply Internal Fuse Not user replaceable Supply Voltage 230V 50Hz nominal Temperature Range 0 ºC to 50 ºC 840 Power Supply Battery Backed Size 350mm x 330mm x 80mm Output Voltage regulated 13 5V Min 13 8V Nom 14 1V Max Output Current 3A continuous...

Page 31: ...Bellcall Digital Door Entry System PD 083 Issue 3A Installation and Operating Manual Page 31 of 46 Diagram A System Wiring BCP1 Panels ...

Page 32: ...Bellcall Digital Door Entry System PD 083 Issue 3A Installation and Operating Manual Page 32 of 46 Diagram B System Wiring BCP VR Panels ...

Page 33: ...Bellcall Digital Door Entry System PD 083 Issue 3A Installation and Operating Manual Page 33 of 46 Diagram C System Wiring BCP VR Panels Single Entrance Up to 35 Phones ...

Page 34: ...Bellcall Digital Door Entry System PD 083 Issue 3A Installation and Operating Manual Page 34 of 46 Diagram D System Wiring BCP VR Panels Single Entrance Above 35 Phones ...

Page 35: ...Bellcall Digital Door Entry System PD 083 Issue 3A Installation and Operating Manual Page 35 of 46 Diagram E System Wiring BCP VR Panels Two Entrance Up to 35 Phones ...

Page 36: ...Bellcall Digital Door Entry System PD 083 Issue 3A Installation and Operating Manual Page 36 of 46 Diagram F System Wiring BCP VR Panels Two Entrance Above 35 Phones ...

Page 37: ... ON AUTO OFF MANUAL C L O C K TIM ER DAY HOUR M IN P ON Mo 1 ON 13 44 56 CO NO NC TS2000 Time Clock optional Exit Button optional Lock Release Branch 1 Branch 2 Branch 3 2nd Entrance Junction Box Example BCP1 Entrance Panel Power Wiring See Cable Distances 2 1 B A AUDIO 12VDC EXIT LOCK TIME DATA All signal cable MUST be CW1308 telephone or Cat5 See Cable Specification Cat5 4 twisted pairs data cab...

Page 38: ...Door Panel Lock wiring options Lock 0 5A 1 0A 12m 1 pair 1 pair 25m 1 pair 2 pair 50m 2 pair 4 pair 50m 2x1mm 2x1mm BSD DIG Door Controller 2 6 3 7 8 9 4 Keypad Connections 5 1 Door Panel Lock Exit button optional Door Monitor Switch optional CO NO NC TS2000 Time Clock Optional 230V Mains PS4 Power Supply 12V N L E C 7 6 5 4 3 2 1 8 H R O T _ _ BD10 Display Module D 0V V 1 4 7 A 2 5 8 0 3 6 9 Z Mo...

Page 39: ...e voltage drop results in at least 10V at the phone while ringing Use the tables in the Cable Requirements section to estimate this Using Cat5 allows 2 pair to be used for power and so double some distances Daisy chain wiring is not recommended unless access can easily be obtained to all phones for maintenance and repair Junction and spur wiring allows a faulty phone or spur to be isolated 2 2 1 1...

Page 40: ...g on an individual flat level at 4 flats per BSC4 2 2 2 2 2 2 1 1 1 1 1 1 B B B B B B A A A A A A Video Video Video Video Video Video Commn 12V 12V Audio Audio Audio Audio Audio Audio Data Data Data Data Data 12V 12V 12V 12V Data Commn Power Supply Input Input Power 1 Power 2 Power 3 Power 4 Input Output Output Output Status Test Test Phone 1 Phone 1 Phone 2 Phone 3 Phone 4 Test Phone 2 Test Phone...

Page 41: ...io Audio Audio Data Data Data Data Data Data BSC4 AD 4 Way Audio Distributor 12V Power Supply Phone 1 Group 1 Input Passthru Phone 3 Group 3 Phone 2 Group 2 Phone 4 Group 4 Org Org Org Org W Org W Org W Org W Org Grn Grn Grn Grn W Grn W Grn W Grn W Grn Blu Blu Blu Blu W Blu W Blu W Blu W Blu Org Org W Org W Org Grn Grn W Grn W Grn Blu Blu W Blu W Blu 12V 12V 230V Mains Power Supply 12V N L E Commo...

Page 42: ...n the interconnecting Cat5 to use as the shared Time clock common The Time clock common signal is sharable across all Bell controller types Keypad Matrix 1 1 2 3 4 5 6 7 8 4 7 A 2 5 8 0 3 6 9 Z X 2 2 1 1 B B A A Controller Controller Control Area 2 Equipment Control Equipment Area 1 BSD DIG BSD DIG Blu Time Clock Common Time Clock Common Blu W Blu W Blu Cat5 Video Video Commn Commn Audio Audio Dat...

Page 43: ...n exit button can still be wired to the Bellcode unit in addition to the bellissimo wiring Note 2 A 12V connection will be required if the 2 units are not sharing a power supply Connecting a Bell PAX1 Proximity Reader Connect the lock release as per this manual Leave the Proximity Reader set to fail secure the BSD controller sets the lock type Note 1 A normally open exit button can still be wired ...

Page 44: ... the BSD controller set to Fail Secure regardless of the type of release used 3 A normally open exit button can still be fitted to the ACT controller in addition to the bellissimo wiring 4 If the 2 units are not sharing a power supply then a connection from BSD controller 12V to ACT 0V will be required 5 Look for the notes on the ACT installation diagram concerning the use of links when the door c...

Page 45: ...ould only be connected once the system has been fully tested Connection is made by 2 leads with spade terminals observe the correct polarity red to positive black to negative Care must be taken to ensure that the terminals of the battery are not shorted together by metal objects as this may constitute a Fire Hazard The Control Cabinet is IP55 rated to exclude dust and is vented to avoid the build ...

Page 46: ...rate numbers Tel 0845 121 4008 Sales and Technical Support FAX 0845 121 4009 E mail sales bellsystem co uk technical bellsystem co uk Website www bellsystem co uk Standards This product complies with European directive 89 336 EEC on Electromagnetic Compatibility and Low Voltage Directive 72 23 EEC Emissions Generic BSEN 61000 6 3 Immunity Generic BSEN 61000 6 1 Low Voltage Generic BSEN 60950 BS EN...

Reviews: