background image

"" 

Cl 

3RO  MODULE 

(630·TYPE  SEll, 5TH  MODULE 

59A  LAMP 

617A KEY 

SOCKET 

26 

39 

29 

14 

39 

40 

16 

41 

34 

42 

36 

6

� 

18 

43 

(631-TYPE  SET) 

598A 

OR 

656A KEY 

1ST 

PICKUP 

OR SIG 

K E Y  

1ST 

27 

KEY 

1 3  

LAMP 

39 

2 N D  

PICK U P  

OR  SIG 

28 

KEY 

29 

2 N D  

KEY 

1 4  

LAMP 

39 

3RD 

PICKUP 

OR  SIG 

30 

K E Y  

3RO 

1 5  

K E Y  

LAMP 

40 

4TH 

PICKUP 

OR  SIG 

KEY 

3 2  

4TH 

3 3  

KEY 

16 

LAMP 

5TH 

PICKUP 

OR  SIG 

KEY 

5TH 

KEY 

LAMP 

6TH 

PICKUP 

OR  SIG 

KEY 

6TH 

KEY 

LAMP 

46 

'-..___../ 

DI20A,  8  (MOl  OR  0200A, 8  (MOl  MOUNTING  CORD 

KEY 

PLUG 

ID O R V  

[RJ 

RJ 

[G] 

[G] 

(BK] 

A-H 

(BK) 

(5-Y] 

S-BK 

(BL) 

[W] 

[BR-GJ 

A-H 

[BR-BK] 

[BR-W] 

(BR-W] 

A-H 

(S-BR] 

8R 

[R-Gl 

[R-Y] 

(R-BLJ 

(R-BLJ 

A-H 

(BK-BLJ 

;i·? 

[BK-WJ 

[R-WJ 

[G-Y] 

[G-BLJ 

A-H 

[G-BL) 

[BL-W] 

[S] 

[O-R) 

(0-G] 

5-BR 

A-H 

(BRJ 

[0-BK] 

[0-BL] 

(0-WJ 

[BL] 

[W] 

[ W J  

( B L - W ]  

A-H 

[S-BL] 

( 5-BL) 

(��]AB1�

6

��l, 

o���:.3a 

0200A, 8  (MDI, 

( M O l  

[9L]  9

L

N

DE

PLUG 

0200A,  8 

( M DI 

(RJ 

* * * * 

[G] 

[9Ll 

[W] 

[BR-Y] 

[BR-BK] 

[BR-BL] 

[BR-W] 

[R-G] 

[R-BK] 

[R-BL] 

(R-W] 

[G-Y] 

[G 

9Kl 

(G-BLJ 

[O-R] 

(0-G] 

[OJ 

[0-BKJ 

CS-Y] 

(S-BKJ 

(S 

Wl 

(S-BR 

CBR) 

[BK-BLJ 

[BK-WJ 

[BL-W] 

[ S J  

[ 0  

9 L l  

[ 0  

W l  

(G-W] 

[Y-BK] 

(Y-BL] 

(Y  W] 

26 

27 

29 

29 

30 

3 1  

3 2  

33 

34 

10 

35 

I I  

36 

1 2  

3 7  

13 

39 

14 

3 9  

1

40 

16 

4 1  

1 7  

4 2  

1

4 3  

19 

46 

22 

47 

VACANT 

23 

49 

2 5  

50 

A75A,  AIOOA  I M DI  OR  AIOOO  CONNECTOR  CABLE 

AIOOA 

( M D I  

CONN 

� 

� 

':i'� 

[S-V] 

[V-S] 

Bl-W 

(W-BL] 

[0-W] 

[W-0] 

[G-W] 

(W-G) 

(BR-W] 

(W-BR] 

[5-W] 

[W-5] 

[B L-R] 

(R-BL] 

[0-RJ 

R-0] 

[G-R] 

R-G 

[BR-R] 

[R-BRJ 

5-R] 

[R-SJ 

[BL-BK] 

[BK-BL) 

(G-V] 

(V-G] 

[BR-V] 

(V-BRJ 

[S-V] 

[V-S] 

[BL-W) 

[W-BLJ 

[O-W] 

[W-0] 

[G-W] 

[W-GJ 

(5-YJ 

(Y-5] 

[BL-VJ 

(V-BL] 

AlCOA 

A75A  CONN 

( M D I 

3 (G-W 

CONN  5 

BINDER) 

(BR-V] 

[V-BRJ 

[5-V] 

[V-S] 

[BL-W] 

[W-BL1 

[O-W] 

(W-0] 

(G-W] 

[W-G] 

(BR-W] 

[W-BR] 

(5-W] 

(W-S] 

[BL-R] 

(R-BL] 

CO-R] 

R-0 

[G-R] 

(R-G] 

(BR-A] 

[R-BR] 

[S-RJ 

[R-SJ 

[S-R] 

[R-S] 

(BL-BK] 

[81<-BL] 

(O-BK) 

[BK-0] 

� 

� 

B I N D E R )  

CD 

(BL-Wl 

(W-Bll 

!O-Wl 

(W-01 

IG-W) 

(W-G) 

I BR-Wl 

IW-BR) 

{5-W) 

{W-S) 

{BL-Rl 

{ R - B L I  

10-R) 

IR-Ol 

(G-R) 

IR-Gl 

(BR-Rl 

IR-BRI 

(S-RI 

IR-S) 

IBL-BKl 

IBK-BLJ 

(0 - BI< l  

tBK-Ol 

I G - B K I  

IBK-Gl 

IBR-BKJ 

IBK-BRl 

15-BKl 

IBK-Sl 

IBL-Vl 

(V-BLl 

10-Vl 

!V-Ol 

IG-Vl 

IV-G) 

IBR-Vl 

15-V) 

(V-5) 

L E A D   OESIG 

R  OR 

T OR  LGI 

A H S OR S I 

R  OR  L2 

T OR  LG2 

A  H 

5  OR  51 

R  OR  L3 

T O R  LG3 

A , H , S   OR  51 

R  OR  L4 

T O R  LG4 

5  OR  51 

R  OR  L 5  

T  OR  LG5 

A H S O R  Sl 

R  OR  L6 

T  OR  LG6 

H S SI OR A i t §  

L , S I  

L 7 0R R i t§ 

LG  57,  LG7  OR  T i t§ 

L ,  52,  LB  OR  P i t§ 

A75A  ONLY 

IUNUSEDI 

VACANT  IN 

AlCOA I MDI 

A N D  AIOOD 

CCI 

.. 

::: 

•  Fig.  4-Module  Arrangements  and  Cord  ond  Coble  Connections  for  Sets  Equipped  With  MD  Cords  (Sheet  3  of  3) • 

BSP 502-610-406-i02_1972-0l-ll.jpg  Scanned by  Frank Harrell,  {Cowboy  Frank) Castle Rock, Colorado  Feb 04,  2012  12:29:25 

"' 

� 

"' 

00 

� 

� 

00 

� 

Summary of Contents for 630A

Page 1: ...nd Division 518 rather than directly to the line circuit Supplementary hold can be furnished in either of the following arrangements a I Hold Transfer A lead from ground to 24 volt Fig 7 connect stored BR V S Y lead from first module plug to any spare mounting cord lead using spare terminal or D 161488 connector Mounting cord lead becomes SP lead at key equipment Fig 7 b Priority Hold Substitute t...

Page 2: ... for complete connections to 3 type speakerphone A t t Kt 40IDB NET IORK A Ll L2 BK I5 BK H 1 0 F I 2 07 Replace the 8R dial with an 8C dial when a telephone set is modified for use with 3 type speakerphone system 2 08 Maintenance of handset dials ringers and modular keys is outlined in sections covering these components located in Division 501 2 09 Refer to Section 502 600 100 for common installa...

Page 3: ... 0 R BK A ob OPENS fg OPENS BR S G 0 V BR OR Y AI LEGEND Y S 11 14 LS LINE 51 ITCH LS 1 0 V DP DIAL PULSE CONTACTS Y A I ON DIAL orr NORMAL CONTACTS S CURRENT COLOR CODE Y O 0 BK LK I 1 MD COLOR CODE t TERM ON NETWORK Lit 0 Y 0 AG BL rt XI S W I S BR G S Y 11 BL Y O R Rl DP e d TO LS riG 5 G R Y BL 0 G TI NOTE I BB Y G o w P3 ONe G Y 0 BL P4 TPA 519430 Fig 2 630 and 631 Type Telephone Set Connecti...

Page 4: ...0C OR 0200F BL W BINDER BL W W BLI 0 W W Ol G W W Gl BR W W BR 5 W W S BL Rl R BL 0 R R 0 1 G R R GJ l8R RJ IS R l IR S IBK BLJ 0 BK BK 0 IG BKJ IBK G BR BK BK BR S BK BL IY BL 10 y IY 0 IG Yl Y G IBR Y IY BRI IS Yl AIOOO I BL W I IW 8cl S 0 W 2 7 I IW 0 3 I G WJ ZB IW G I I I I BR W W SI L a I I10 I 13 38 I I I l tO R R 01 IG R 1tR GI IBR RI I I S RI IR S 18L BK BK BL 10 BKI BK 0 I IG BKI BK G IB...

Page 5: ...S STRAP BETWEEN 1 HI Sl AtC1 58 TEftlllltliALS C Tl KEY liii AY IE MIW COftO Ol f EQUtv lLENT TO II T AL M 617A KEY TO A OtSSMI AR GROUND OR A NONGI tOI tOED CIRCUIT lel ILATED AND STORED t DEAD EMDED I 2ND MODULE 630 TYPE SETS 4TH MODULE 631 TYPE SETS CONNECTS TO TB 1ZI SG S98A OR 6 S6A KEY 2ND MOOLILE 630 TYPE SETS 2ND 3RO OR 4TH MODULE 631 TYPE SETS 1ST PICKUP OR SIG KEY LAMP 2ND PICKUP OR SIG ...

Page 6: ... 8 To TOR LG6 A H S 51 OR AI L 56 L l2 Oft F l LG Sl2 LGI2 OR LP SPAR SPARE SPARE A75AONLY IJNUSEDJ TO KEY TELEPHONE SYSTEMS IA IAI IA2 ANO 6A VACANT IN AIOOO t Fig 3 Module Arrangements and Card and Cable Connections for Sets Equipped With Even Count Color Coded Cords Sheet 3 of 3 BSP 502 610 406 i02_1972 01 Q6 jpg Scanned by Frank Harrell jCowboy Frank Castle Rock Colorado Feb 04 2012 12 27 31 ...

Page 7: ...2 A H Rl R A H in Fig 3 I VI I I Note Roman numerals in parentheses indicate terminal board designations Lead is spade tipped insulated and stored V G V G V G V G BL W BL W BL W BL W 2ND 3RD 4TH 5TH KEY KEY KEY KEY A H A H A H A H II III IV V A H A H A H A H II III IV V A H A H A H III IV V A H A H A H II IV V A H A H X A H II III VI V A H A H A H A H II III IV V LINE STRAP SWITCH BL V 0 V BR R Y ...

Page 8: ... REWOVE COMMON LEAD OF ADO ON CONFERENCE BUTTON CONVERTED TO SIGNALING FROI I A H TERWINAL AND CONNECT TO PB THE 617A KEY WAY ALSO BE USED IN A SIWILAR WANNER ALSO SEE NOTE 5 4 WHEN THE 617A KEY IS REQUIRED AS A DUAL PURPOSE KEY THE BRASS STRAP BETWEEN THE 51 AND SG TERMINALS Or THE KEY MAY BE REMOVED USE M I W CORD OR EQUIVALENT TO CONNECT 51 TERM I NAL or 617A KEY TO DISSIM I LAR GROUND OR A NON...

Page 9: ... TH KEY LAMP v 5TH PICKUP g OR SIG c __ KEY 5TH t L_ KEY LAMP A H A H I II A H I 8 s w1 R W S BL W BR R BR G BR Y BR BK BR Bl BR W R G R Y R BK R Bl l R W zm G Yl M3 G BK G Bl VACANT I 28 4 29 5 I 30 6 1 32 8 9 34 10 35 II 36 12 31 13 38 14 39 15 40 16 41 17 42 18 43 19 44 20 45 t 21 46 22 47 23 48 24 49 25 50 00 W G BR W W BR S W W S BL R R BLl 0 R R 0 G R R G BR R R BR R R 5 BL BK BK BL 0 BK BK ...

Page 10: ...L Y Y BL 0 Y fY 0 G Y Y GJ BR Y Y BR S Y Y SJ BL VJ tv 6Ll 0 V V Ol G Vl V G BR Vl V BR 0 YJ Y O G Y Y GJ BR Yl Y 6RJ 5 Yl Y S 6L Vl V 6Ll to Vl V OJ G YJ Y Gl 6R YJ 6R Yl A75A AIOOA MD OR AIOOO CONNECTOR CABLE g AIOOA MD CABLE CONN 3 w I S V tv SJ BL WJ W 6LJ d Wi 0 W I 1 W 01 q G WJ W GJ bi BR WJ I W BR v rs w W S K 6L RJ R 6LJ 0 RJ _L R 01 G R fA G f 6R RJ R BR R R SJ BL BK BK BLl G Vl rv GJ 6R...

Page 11: ...40 16 4 1 1 7 4 2 18 4 3 19 w 46 22 47 VACANT 23 49 s 2 5 50 A75A AIOOA IM DI OR AIOOO CONNECTOR CABLE AIOOA M D I CONN 3 i iii S V V S Bl W W BL 0 W W 0 G W W G BR W 2 W BR 5 W W 5 BL R R BL 0 RJ R 0 G R R G BR R R BRJ 5 R R SJ BL BK BK BL G V V G BR V V BRJ S V V S BL W W BLJ O W W 0 G W W GJ 5 YJ Y 5 BL VJ V BL AlCOA fl A75A CONN M DI t 3 G W CONN 5 rj BINDER BR V V BRJ 5 V V S BL W W BL1 O W W...

Page 12: ...odule first If more than six five with common signaling are required use module preceding right hand position repeat connection modifications as shown in table 2 All key positions are arranged in the shop as pickup positions To convert to signaling nonlocking remove the screw detail P 10E837 from the plunger at the key position to be converted Make the necessary connection changes as shown in Tabl...

Page 13: ...re STORED R T A A H 0 R 0 G 0 BK S BR 0 R 0 G 11 11 36 36 37 G 37 12 t 11 t 36 t BL Y Y BL 0 Y Y 0 BL Y Y BL Y 0 11 16 36 41 37 G 12 t 11 t 36 t G 42 To ext sta Insulate and Store To ext sta Insulate and Store SG Insulate TBVI and store To ext ringer Insulate and Store or buzzer Insulate Ringer and TB Store 2 or A 3 Buzzer Insulate D c and Store A c Cap c R T TBl TB1 N o tes 1 The O R o r B L Y an...

Page 14: ... 8 LP 43 I CURRENT co Co rco oE MD COLOR CODE y y y ME VOLU CONTROL TR S TRM TE t TCH MU S W I ON MP LA t L 0 TO F I G I OR 2 0 B L 9 o e j O 0 Co I 9 1 Yf J 667 TYPE TRANSMITTER Fig S 661 A MD and 667 Type Transmitter SSP 502 610 406 i02_1972 01 14 jpg Scanned by Frank Harrell Cowboy Frank Castle Rock Colorado Feb 04 2012 12 30 39 Ill m n 0 z 0 Tl I I 1 3 0 I 38 0 I I w P I I r 1 4 I 0 I I I I I ...

Page 15: ...CONNECTIONS FOR EXTERNAL SPEAKERPHONE FOR SETS WITH EVEN COUNT MOUNTING CORDS LEAD REMOVE CONNECT WIRE OR LEAD COLOR DESIG BL Y Rl Mtg Cord Y BL Tl BL W Binder 0 Y AG Y 0 LK G Y P4 Y G P3 Stored location t Network terminaL I FROM TO 2 RRt 5 G 9 12 11 G BK SP 34 E S U P L 0 I I I t I0 1 I 1 35 I H 11 I I 24V H i 42 E NOTE 2 HOLD HOLD NOTES I I I o I I 1 I I o 36 f I o 1 2 f I 0 37 f I I I I r t 1 8...