background image

SECTION 

502-502-101 

Ordering·  Guide 

2.02 

Basic  Telephone  Sets: 

Set,  Telephone,  1500D-* 

Set,  Telephone,  1554B-* 

*Refer  to  Table 

for  colors 

TABLE  A 

COLOR  ORDERING  GUIDE* 

TEL SET,  CORD 

COORDINATED 

HOUSING, HANDSET 

FACEPLATEt 

COLOR 

COLOR 

Black 

-03 

Charcoal 

-70 

Ivory 

-50 

Muted  Ivory 

-80 

Moss  Green 

-51 

Light  Green 

-

7

Red 

-53 

Muted  Red 

-69 

Pastel  Yellow 

-56 

Light  Yellow 

-72 

White 

-58 

Light  Gray 

-73 

Rose  Pink 

-59 

Muted  Pink 

-74 

Light  Beige 

-60 

Muted  Beige 

-75 

Light  Gray 

-61 

Charcoal 

-70 

Aqua  Blue 

-62 

Muted  Blue 

-76 

Turquoise 

-64 

Muted Turquoise 

-77 

• 

Refer  to  Section  500-120-100  for  promoted 
colors. 

Faceplates  of  same  color  as  housing  may  be 

ordered  (optional). 

Design  Features  and  Application: 

2.03 

The  1()00D  and  1554B  telephone  sets  are 
general  purpose  desk- and  wall-type  sets, 

respectively,  for  use  in  PBX,  individual,  and  party 
line  service. 

Optional  Features 

2.04 

End-to-End Signaling: 

Requires  installation 

of  guard  assembly  (see  Table  C). 

Page 

3. 

INSTALLATION 

3.01 

Exercise  care  not  to  damage  line  switch  on 

early  models  of 1554B sets  without  line  switch 

guard  when  drilling  or  driving  screw  in  mounting 

hole. 

4. 

MAINTENANCE 

4.01 

Replaceable  Apparatus 

(Refer  to  Table  B 

for  component  ordering  guide.):  Component 

parts  should  be  maintained  in  accordance  with 
section  covering  the  particular  item. 

4.02 

To  remove  housing  on  1554B  telephone  set: 

(1} 

Remove  number  card  holder  and  number 
card  with  KS-16750L2  releaser. 

(2)  Loosen  captive  screws  located  beneath 

number  card. 

(3)  Remove  housing. 

(4)  To  replace  housing  reverse  procedure. 

4.03 

Plungers,  operating  bracket  switch,  and  line 

switch  shall  move  freely  without  binding  or 

squeaking. 

• 

Clean  with  KS-2423  cloth  moistened  with 

KS-7860  petroleum  spirits. 

• 

Lubricate  plungers  and  bearing  surfaces  with 

No.  2  or  softer  graphite  pencil. 

• 

Clean  line  switch  contacts  when  required 

with  265C  tool. 

• 

Replace  set  if  other  trouble  exists  in  line 
switch  assembly. 

SSP S02

-5

02

-

101

·

i

01

_

1970

-

02

-

02

.

j

p

Scanned by Frank Harrell,  (Cowboy  Frank) Castle  Rock, Colorado  Jan 30, 2012  22:38:46 

Summary of Contents for 1500D

Page 1: ...IIIIIIII 11mIii IiiiiI i sss 2 _ o c 15549 TELEPHONE SET maintenance and connection information for general purpose telephone sets previously contained in Sections 502 510 111 502 510 440 and 502 510 431 which are hereby canceled 2 01 General purpose TOUCH TONE dial desk and wall type telephone sets merican Telephone and Telegraph Company 1970 Printed in L l BSP 502 502 101 101_1970 02 0l jpg Scan...

Page 2: ...uard assembly see Table C Page 2 3 INSTALLATION 3 01 Exercise care not to damage line switch on early models of 1554B sets without line switch guard when drilling or driving screw in mounting hole 4 MAINTENANCE 4 01 Replaceable Apparatus Refer to Table B for component ordering guide Component parts should be maintained in accordance with section covering the particular item 4 02 To remove housing ...

Page 3: ...NG PARTY REFER TO TABLE D FOR CLASSES OF SERVICE NOT SHOWN INDICATES CURRENT COLOR CODE INDICATES MD COLOR CODE WITH 2 5A3 DIAL Fig 2 15000 Telephone Set Connections BSP 502 502 101 i01_1970 02 03 jpg Scanned by Frank Harrell Cowboy Frank Castle Rock Colorado Jan 30 2012 22 39 11 ISS I SECTION 502 502 101 Page 3 ...

Page 4: ... G DIAL LEADS MAY APPEAR ON F IN SETS EQUIPPED WITH 40100 NETWORK 4 LINE SWITCH OFF HOOK SEQUENCE I b e CLOSES 4 a b OPENS 121 d e CLOSES 51 f g OPENS 3 j k CLOSES 5 SET FACTORY WIRED FOR BRIDGED SERVICE REFER TO TABLE E FOR CLASSES OF SERVICE NOT SHOWN 6 REFER TO TABLE F FOR MODIFICATIONS FOR IAI OR IA2 KTS INSULATED AND STORED 0 BKI WITH 25W3 DIAL WITH 25A3 liD DIAL Fig 3 1 5548 MD Telephone Set...

Page 5: ...D053 Telephone set must be equipped with a 25W3 or 25Y3 dial as appropriate if intended for use with amplifying handset or 3 type speakerphone system ISS 1 SECTION 502 502 101 TABLE C POLARITY GUARD CONNECTIONS FOR 1500D AND 1554B TELEPHONE SETS DISCONNECT CONNECT FROM TO LEAD NETWORK NETWORK POLARITY GUARD Dial BK RR T Line Switch BR c s Polarity G RR Guard w c Depending on class of service set T...

Page 6: ... L2 L2 A A Line Switch W S W F F F c c BR S BR c c c F F Note To permanently silence ringer for all classes of service except identifying ground connect Y mtg cord lead with R mtg cord lead at conn block a For 1000 ohm ground insulate and store or place S R ringer lead on unused terminal b For 2650 ohm ground insulate and store or place BK ringer lead on unused termi nal Current color code MD colo...

Page 7: ...manently a For all classes except tip party with identifying ground remove BK ringer lead insulate and store or place on unused terminal b For tip party with 1000 or 2650 ohm identifying ground remove R ringer lead insulate and store or place on unused terminal TABLE F MODIFICAliONS FOR 1 A1 OR 1A2 KTS FOR 1554B TELEPHONE SETS WIRE OR LEAD DISCONNECT CONNECT FROM TO s A Line y 2 Ll Switch BR c 3 B...