Page 9

P74789

Reversing your Front Door

1. Open door and reverse handle. See Figure A.

2. Secure door with one hand while you pull down the top hinge pin (Figure B) with the other.

3. Grab door on both sides and lift up to remove door and set it aside.

4. Remove hinge pin brackets using Phillips head screwdriver, turn and reattach hinge pin 

brackets to opposite corners (Figure C).

5. Remove button plugs by pushing from the back side and retain for reuse.

6. Remove latch bracket and door stops (2) using Phillips head screwdriver while holding 

lock nut in back. Turn and place bracket and door stops (2) on the opposite side (Figure D).

7. Put push buttons back into holes on opposite side.

8. Rehang door.

NOTE:

The best time to reverse the door is prior to installing the equipment. 

Standard factory door configuration is left-hand hinged.

Figure A

Remove handle

and reverse

Figure B

Summary of Contents for RK1000

Page 1: ...Belkin Enclosure User Manual v 1 0 0 P74789 Belkin Enclosure User Manual ...

Page 2: ...Belkin Enclosure User Manual v 1 0 0 P74789 This page is left intentionally blank ...

Page 3: ...8 Removing your Casters and Levelers 8 Removing and Installing your Side Panels 9 Removing and Installing your Top Panel 10 Ganging or Networking your Enclosures 11 Reversing your Front Door 12 Reversing your Front Door 13 Reversing your Front Door 14 Adjusting your Vertical Mounting Rails 15 Installing your Equipment 16 Grounding Studs 16 Cable Management 17 Cable Access 18 Specifications 19 Acce...

Page 4: ...closures Nominal Nominal Enclosure Enclosure Part Number RMU Height Height w Casters Width Description RK1000 42 80 25 24 Enclosure with Sides RK1001 42 80 25 24 Enclosure w o Sides RK1002 24 48 75 24 Enclosure with Sides Side panels are available for those Enclosures ordered without sides Side panels are available in pairs with hardware included Part Number Description RK5009 Side Panels for 42U ...

Page 5: ...duct Inventory Features of the Enclosure 8 7 1 2 3 4 5 6 9 9 9 9 9 1 Side Panels with Locks 2 Vertical Rails Adjustable 3 Reversible Front Doors 4 Fully Welded Frame 5 Leveling Feet Adjustable 6 Casters 7 Split Rear Doors 8 Vented Top Panels 9 Cable Access ...

Page 6: ...allation When this caution symbol appears in this User Manual the information that accompanies it is critical to your safety and the prevention of damage to product Before unpacking please make sure you have the following tools Phillips Screwdriver Utility Knife Level 3 4 Open Ended Wrench 1 2 3 8 and 7 16 Hex Sockets ...

Page 7: ...to the back of the skid Proceed until all four casters contact the floor 5 Verify that you have received all hardware and components with your Belkin Enclosure Contact Belkin support if you feel items are missing Unpacking your Enclosure DETAIL A A NOTE Skid should be saved if you need to reship the Enclosure Belkin is not responsible for damage caused by re shipment of this Enclosure Please recyc...

Page 8: ...losure is taken off of the casters 3 Using a level and your wrench adjust the levelers so that your Enclosure is level Removing your Casters and Levelers The following steps require two or more people 1 Using two or more persons lay your Enclosure on it s side 2 Unscrew the levelers 3 Using a 1 2 hex socket remove the 5 6 nuts holding the casters 4 Return Enclosure to upright position Installing y...

Page 9: ...ving and Installing your Side Panels 1 If side panel is locked please unlock 2 Slide both latches toward the center of the side panel and carefully pull side panel toward you 3 Lift side panel up and remove from Enclosure 4 To re install reverse above steps ...

Page 10: ...10 32 Phillips pan head screws This top panel can be replaced with optional fan tops by removing the four 10 32 screws Please see chart below Tools required Phillips Pan Head Screw Driver 10 32 Phillips Pan Head Screw Part Number Description RK5003 Perforated top RK5004 3 muffin fan top 225 CFM RK5005 Single 10 fan top 500 CFM RK5006 Double 10 fan top 1100 CFM ...

Page 11: ...ing hole 4 locations Enclosure A Enclosure B Use Belkin part number RK5008 optional enclosure baying kit No additional tools required 1 Remove plastic button plugs from enclosure corner posts 4 2 Remove at least one side panel from adjoining enclosures 3 Line up enclosures install baying hardware ...

Page 12: ...and reattach hinge pin brackets to opposite corners Figure C 5 Remove button plugs by pushing from the back side and retain for reuse 6 Remove latch bracket and door stops 2 using Phillips head screwdriver while holding lock nut in back Turn and place bracket and door stops 2 on the opposite side Figure D 7 Put push buttons back into holes on opposite side 8 Rehang door NOTE The best time to rever...

Page 13: ...Belkin Enclosure User Manual v 1 0 0 Page 10 P74789 Reversing your Front Door Figure C ...

Page 14: ...Belkin Enclosure User Manual v 1 0 0 Page 11 P74789 Figure D Reversing your Front Door Latch Bracket Door Stops ...

Page 15: ...his depth allows for the installation of most rack mountable equipment Rails are infinitely adjustable front to back The best time to move the rails is before installation of equipment To adjust your rails loosen the rail bolts 4 with a 7 16 hex socket Use a 7 16 Hex Socket to loosen bolt Vertical Mounting Rail Full Depth Front to Rear Adjustability ...

Page 16: ...ion 2 Base 2 Front door 4 Rear doors 2 each 2 Side panels 1 each Please refer to part number RK5038 for the optional Belkin enclosure grounding kit A 1 75 1 RMU 30 29 31 Load your rack from the bottom up placing the heaviest components at the lowest position Please follow the individual instructions that are provided with the components you are installing After installation of your equipment exten...

Page 17: ...cription Image RK5000 Vertical Lacing Bar RK5001 Waterfall Cable Manager RK5002 Vertical Finger Cable Manager RK5012 Double Sided 1U Cable Manager RK5013 Double Sided 2U Cable Manager RK5016 Single Sided Cable Manager RK5017 Low Density Cable Organizer Cable Management ...

Page 18: ...hese knock outs can be removed when ganging two or more Enclosures together These knock outs will still allow you to have cabinet to cabinet access with a side panel in place Access through the bottom is achieved through one large center opening an additional rectangular point in the rear and four grommeted access points 2 1 2 x 6 4x 3 3 4 x 7 1 2 2x 2 Diameter 4x 3 3 4 x 9 1x 13 x 21 1x Bottom Ca...

Page 19: ... 335 lbs 152 kg 315 lbs w o sides 147 9 kg Open Area Front Door 861 8 in2 5560 cm2 484 8 in2 3218 cm2 Open Area Rear Door 830 2 in2 5356 cm2 474 3 in2 3060 cm2 Open Front Door Area Measured per U 20 5 in2 132 3 cm2 20 2 in2 130 3 cm2 Open Rear Door Area Measured per U 19 8 in2 127 7 cm2 19 7 in2 127 1 cm2 Wiring Clearance between Vertical Rail Front Door 2 5 in 6 35 cm 2 5 in 6 35 cm Static Weight...

Page 20: ...b Capacity RK5021 28 Deep Front Rear Mount Stationary Vented Shelf RK5022 Pivoting Keyboard Tray with Mouse Tray RK5023 Stationary Shelf Cantilevered RK5024 Monitor Shelf Sliding Keyboard Tray w Mouse Pad 220 lb Capacity RK5027 Stationary Front Mount Shelf RK5030 Filler Panel Kit 2 ea of 1U 2U 3U RK5031 1U Filler Panel set of 2 RK5032 2U Filler Panel set of 2 RK5033 3U Filler Panel set of 2 RK5034...

Page 21: ...uipment modification or alteration How to get service To get service for your Belkin Enclosure you must take the following steps 1 Contact Belkin Corporation at 501 W Walnut St Compton CA 90220 Attn Customer Service or call 800 223 5546 within 15 days of the Occurrence Be prepared to provide the following information a The part number of the Belkin Enclosure b Where you purchased the Enclosure c W...

Page 22: ...ot allow limitations on how long an implied warranty lasts so the above limitations may not apply to you IN NO EVENT SHALL BELKIN CORPORATION BE LIABLE FOR INCIDENTAL SPECIAL DIRECT INDIRECT CONSEQUENTIAL OR MULTIPLE DAMAGES SUCH AS BUT NOT LIM ITED TO LOST BUSINESS OR PROFITS ARISING OUT OF THE SALE OR USE OF ANY BELKIN ENCLOSURE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES This Warranty gi...

Page 23: ...44 0 1933 31 2000 fax Belkin B V Boeing Avenue 333 1119 PH Schiphol Rijk The Netherlands 31 0 20 654 7300 31 0 20 654 7349 fax Belkin Ltd 7 Bowen Crescent West Gosford NSW 2250 Australia 61 0 2 4372 8600 61 0 2 4372 8603 fax Tech Support US 310 898 1100 ext 2263 800 223 5546 ext 2263 Europe 00 800 223 55 460 Australia 1800 235 546 New Zealand 0800 235 546 2005 Belkin Corporation All rights reserve...

Page 24: ...Belkin Enclosure User Manual v 1 0 0 Page 21 P74789 This page is left intentionally blank ...

Reviews: