F E AT U R E S

The PureAV comes with three 

Diagnostic Indicators

, plus an 

Amber Master

Switch

light. When you plug the unit into a live, 120V AC/60Hz outlet, these

lights let you know that protection is activated and warn of a power problem
before you connect your equipment.

Protection (Yellow)

indicates your surge protection is 

functioning properly.

Line OK (Green)

indicates line integrity.

Line Fault (Red)

indicates wall outlet in use has existing 

ground fault, or is improperly wired.

Protection (Yellow):

This light should come on when the unit’s power 

switch is turned to the “ON” position. If this light goes out at any time, 
it means that your surge protector has “sacrificed itself” to protect your
equipment and should be replaced. Please contact Belkin Components for 
a free surge protector replacement.

Line OK (Green):

This light should also come on when the power switch is turned

on. It shows that 120V AC power is present with no wiring faults and it is safe to
plug and use connected equipment.

Line Fault (Red):

If on, this light indicates that a wiring fault has been detected.

This may be the result of a lack of grounding or reversed phases, among other
problems. A qualified electrician should be notified so that the problem can be
corrected before plugging in devices. 

Master (Amber):

This on/off switch provides a built-in, automatic shutdown, 

15-Amp circuit breaker. The light should come on when the unit is plugged into a
120V AC/60Hz outlet and switched to the “ON” position. 

Important:

If the current

draw exceeds 15 Amps for an elongated period of time, the circuit breaker will
shut down surge protector power to prevent damage. Allow a brief time for the
PureAV to cool before resetting the circuit breaker switch. (To reset, simply press
the switch.) 

Power Filter Technology (PFT):

As mentioned earlier, this design prevents devices

that are plugged into a given receptacle bank from transferring contamination to
a device plugged into another receptacle bank. Each pair of receptacle banks is
isolated from the other pairs within the PureAV. (The 10-outlet PureAV has five
pairs of PFT receptacle banks.)

The PureAV Isolator provides increasing levels of protection and filtration from
surges, spikes, lightning strikes, and EMI/RFI. When AC power travels from the
wall outlet and throughout each successive pair of receptacle banks, each power
filter or “graduating filtration” level increases the isolation, filtration, and

3

P73999_FG1033-12.qxd  9/19/02  9:03 AM  Page 4

Summary of Contents for PUREAV F9G1033-12

Page 1: ...13 PureAV Home Theater Surge Protector CLEARER PICTURE CLEANER SOUND User Manual F9G1033 12 ISOLATOR...

Page 2: ...etal Oxide Varistors MOVs Differential Isolation Coils and Special Capacitors that are dedicated to each successive pair of receptacle banks Each power filter or graduating filtration level isolates a...

Page 3: ...to connect the PureAV s cable antenna marked OUT to the appropriate input on your cable or antenna device 5 Phone Fax Modem Data Connections Connect a modular phone cord from the wall jack to the Pur...

Page 4: ...grounding or reversed phases among other problems A qualified electrician should be notified so that the problem can be corrected before plugging in devices Master Amber This on off switch provides a...

Page 5: ...ny defective product free of charge Belkin Components will repair or replace at its option any equipment that is damaged by a transient voltage surge spike or lightning strike an Occurrence while prop...

Page 6: ...or has been improperly installed altered in any way or tampered with Belkin Components determines that the damage did not result from the occurrence or that no occurrence in fact took place the repair...

Page 7: ...oduct must be made within 15 days from the date of the occurrence and must be accompanied by a receipt for the damaged equipment or the warranty is void Warranty is valid in USA Canada Puerto Rico and...

Page 8: ...6GL United Kingdom Tel 44 0 1933 35 2000 Fax 44 0 1933 31 2000 Belkin Components 501 West Walnut Street Compton CA 90220 USA Tel 310 898 1100 Fax 310 898 1111 2002 Belkin Components All rights reserv...

Reviews: