15

14

USING YOUR SWITCH

Powering Up the Systems

Once all cables have been connected, power up the connected computers. All
computers can be powered on simultaneously. The Switch emulates both a mouse
and keyboard on each port and allows your computer to boot normally.

The computer connected to port “01” of the Primary Switch will be displayed on the
monitor. Check to see that the Switch is working normally by use of mouse, keyboard,
hot keys, and/or IntelliView. Proceed to do this with all occupied ports to verify that
all computers are connected and responding correctly. If you encounter an error,
check your cable connections for that computer and reboot, if necessary. If the
problem persists, please refer to the “Troubleshooting” section of this User Manual.

Now that you have connected your computers to your Switch, it is 
ready for use. You can select connected computers by key commands or the 
On-Screen Display. It takes approximately 1–2 seconds for the video signal to 
refresh (depending on monitor and graphics card used) after switching computers.

Note: For hot keys (e.g. up and down arrows) and AutoScan, the order of progression,
when switching from one computer to the next, is dictated by the order of the
computers in the list box (on the main page of IntelliView).

USING YOUR SWITCH

INSTALLATION

Selecting a Computer Using Keyboard Hot Key Commands

Command the Switch to switch ports through simple keyboard key sequences. To
initiate a keyboard command to the Switch, press the “Scroll Lock” key twice within
one second (you will hear a beep), then input the key sequence for the specific
command. Below is a list of the different keyboard commands:

Note: You will have approximately two seconds after the beep to complete each hot 
key sequence.

For hot keys (e.g. up and down arrows) and AutoScan, the order of progression from
one computer to the next is dictated by the order of the computers in the list box
(in the main view of IntelliView).

Note: Alternatively, the control keys can be used to enter commands (usage is identical
to the Scroll Lock key); this provides compatibility for keyboards that don’t have Scroll
Lock keys.

Using the AutoScan Function

In AutoScan mode, the Switch remains on one port for a configured interval 
(1–99 seconds) before switching to the next computer. The time interval is
configured in IntelliView.

To enter AutoScan mode, press the AutoScan button in IntelliView:

• AutoScan mode will continue indefinitely until terminated by pressing any valid

hot key sequence.

• When the Switch is in AutoScan mode, it is also in View-Only mode. This means

that input from the console will not be transmitted to the server in focus. Cancel
AutoScan to regain control of the computer.

• The AutoScan time varies by computer, and is configured in IntelliView.
• AutoScan will skip any servers that the user does not have permission to view.

Using the MultiView Feature

This Switch is capable of allowing multiple users to view the same server
simultaneously; however, only the first console to focus on that server will have
control (be capable of input). When a second console focuses on the same server,
the View-Only console’s banner will display “View-Only”. If the banner is enabled on
the viewing console, then the “View-Only” banner will be displayed as long as that
console is focused on a computer it can’t control. If the banner is disabled on the
viewing console, then the “View-Only” banner will be displayed for five seconds.

If the controlling console switches focus to another computer, then control will be
granted to another console.

Summary of Contents for OmniView F1DC108B

Page 1: ...ERPRISE Quad Bus Series F1DC108B Expandable to control up to 256 servers from four consoles OmniView 1U Rack Mount Console with 8 Port KVM Switch Control up to eight servers from one integrated console and KVM Switch ...

Page 2: ... switch on the market The Rack Mount Console is engineered to work with the most advanced server room and laboratory environments offering Dual rail system allowing the LCD panel to be displayed by itself Video resolution support of up to 1024x768 PS 2 and USB mix and match support for input and output devices Multi console support IntelliView Graphical On Screen Display OSD Computer and group nam...

Page 3: ...t KVM Switches or as many as 256 when using the 16 Port KVM Switches IntelliView Graphical On Screen Display OSD with Mouse Support The IntelliView Graphical OSD feature simplifies server management by allowing you to assign individual names to each connected server throughout the system Groups of computers can also be created allowing you to efficiently organize your enterprise IntelliView also p...

Page 4: ...4 to 140 F 20 60 C Humidity 0 80 RH non condensing Maximum Altitude 10 000 feet Console Specifications Max LCD Resolution 1024x768 Keyboard Type 105 key PS 2 compatible Mouse Type PS 2 compatible touch pad Enclosure Metal enclosure Dimensions 19 W x 1 75 H x 29 L in 482 6 x 44 5 x 736 6mm Weight 29 2 lbs 13240g Warranty 2 Year Limited Warranty Note Specifications are subject to change without noti...

Page 5: ... sequentially monitors all attached servers BANK The address of a KVM Switch when used in a daisy chain configuration BANK numbers range from 0 to 15 typically set by adjusting the DIP Switch to the appropriate setting Console The keyboard video monitor and mouse Console Ports The connectors on the back of the KVM Switch for connection of the console Control In terms of switching between ports con...

Page 6: ... the port for the first two computers for best results screw the connectors into the Switch and the computer when possible 2 Connect the USB connector of your KVM cable to the computer If your computer is running Windows Me or later skip to step 6 Otherwise continue with step 3 3 Boot up the computer you wish to connect via USB as you would normally with the keyboard mouse and monitor connected di...

Page 7: ...tch is used for proper identification of the KVM Switch either in a standalone or multiunit configuration For a single unit configuration set the BANK DIP Switch on the KVM Switch to the Standalone BANK address 00 setting This is the factory default setting For multiunit configuration the BANK DIP Switch on the Primary Switches must be set to BANK address 00 to 03 Secondary Switches must be set to...

Page 8: ...notes their respective BANK addresses Note If the Switches still do not enumerate correctly check that all Switches have the correct BANK address assigned to them and that all daisy chain cables are connected properly Enabling Daisy Chain Mode on BANK 00 8 Primary BANK 00 must be configured to daisy chain mode by the administrator This is only to be set on BANK 00 a Open IntelliView and enter Setu...

Page 9: ... approximately two seconds after the beep to complete each hot key sequence For hot keys e g up and down arrows and AutoScan the order of progression from one computer to the next is dictated by the order of the computers in the list box in the main view of IntelliView Note Alternatively the control keys can be used to enter commands usage is identical to the Scroll Lock key this provides compatib...

Page 10: ...ar will activate IntelliView s control in focus same as clicking on the control If the list box is in focus then pressing the space bar will give the console control of the highlighted computer USING YOUR SWITCH Pressing Enter will activate the control in focus if the control is on a button or inside an edit box However if the focus is on another type of control e g the list box the Enter key will...

Page 11: ...es simultaneously the second administrator will be presented with an error message USING YOUR SWITCH Login Button Click on the Login button or press Alt L on the keyboard to display the login dialog box which lets the user switch to a different account see the Login Dialog section Logout Button Click on the Logout button or press Alt T on the keyboard to return to Guest level access If the adminis...

Page 12: ...isplays the name of each connected computer The computer list can be sorted on this field by clicking on the column header User Columns 1 2 3 G These columns allow administrators to set the access rights to each computer for each of the User groups 1 2 3 and Guest To restrict a user from a particular computer click in the corresponding cell in the list box The padlock indicates that the user colum...

Page 13: ...NK 00 Display Version Numbers This screen displays product information including the model number and the firmware revisions Restore Factory Defaults Clicking on this button will restore all user configurable settings to their default values The user is presented with a confirmation screen before this action is applied Error Messages and Dialogs From time to time it will be necessary to display me...

Page 14: ...de capability you can update your Switch at any time through a simple parallel connection Internet upgrade capability ensures that your Switch is always the most current version on the market with the latest features and enhancements Does the Switch support Microsoft IntelliMouse The Switch supports mice from Microsoft Logitech Kensington and Belkin Please contact Belkin Technical Support for comp...

Page 15: ...is Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme á la norme NMB 003 du Canada Belkin Corporation Limited Five Year Product Warranty Belkin Corporation warrants this product against defects in materials and workmanship for its warranty period If a defect is discovered Belkin will at its option repair or replace the product at no charge ...