background image

           

 

 

 

 

 

 

 

 

 

 

 

INTRODUCTION 

Thank you for purchasing a Belkin Uninterruptible Power Supply 
(UPS). Each year, several natural and man made occurrences put 
the power supplied to your work stations in your home or office in 
jeopardy. At risk is your hardware, software and data because of 
these power problems. 

IMPORTANT!

 

Please save this manual! 

It contains important operating instructions and warranty information 
pertaining to your UPS. 
 

Please save or recycle the packaging materials! 

The UPS packaging was designed to provide protection during 
shipment and delivery. This packaging can be reused should you 
have return the UPS for service. Damage sustained during transit is 
not covered under the warranty. 

 
Federal Communications Commission Interference Statement

 

This equipment has been tested and found to comply with the limits 
for a Class B digital device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment 
generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. To assure continued 
compliance, use only shielded interface cables when connecting to 
computer or peripheral devices. Any changes or modifications not 
expressly approved by the party responsible for compliance could 
void the user’s authority to operate this equipment. 
 

CONTENTS 

You should have received the following: 
1 – UPS unit 
1 – Sentry Bulldog Shutdown Software 
1 – Serial Cable 
1 – USB Cable 
1 – Phone Line Cable 
 

UPS FEATURES AND FUNCTIONS 

Before installation, please inspect the UPS upon receipt. Make sure 
that nothing is damaged. 
 
Your UPS features 3 LED indicators. Each is marked by a power 
icon, please familiarize yourself with this chart as it will assist you in 
the use of your UPS. 

 

Chart 1 

 
 
 
 
 

 

Front Panel 

   

 

 

 

 

 

 

 

 

 

Diagram 1 

 

1. 

 

UPS Outlets (See #1 on Diagram 1) 

These outlets are your battery back up outlets. We strongly 

recommend that only sensitive equipment such as your computer 

and monitor should be plugged into these outlets. 

Never plug in any 

printer.

 

 

 

Should a power outage occur, your battery backup will automatically 

turn on. Power (utility or battery) is not supplied to these outlets when 

the UPS is switched off. 

 

 

Please do not plug any surge protectors or power strips into the 

battery back-up outlets (i.e. daisy chaining).

 

 

 

2. 

 

SURGE Protected outlets (See #2 on Diagram 1) 

These outlets do not provide power during a power outage. 

 

 

Equipment such as computer peripherals, printers, fax machine’s, or 

a desk lamp may be plugged into these outlets. These outlets are not 

controlled by the On/Off button. 

 

3.  The On/Off button has 3 functions: 

1. Turns on the UPS. Depress button at least 2 

seconds. The green light will come on. 

 
2. Cold Start function. Assuming the battery is 

charged the UPS will work without it being 
plugged into an outlet. Depress and hold the key 
for at least 2 seconds to turn on the UPS. The   

 
3. Silence function. During “On Battery Mode”, the 

audible sound can be turned “ON” or “OFF” by 
depressing the switch. 

 

 

Side Panel A 

 

AC Input

Circuit Breaker

IN

Push to Reset

Refer to Bottom for

Cautionary Markings

 Phone/Fax

Modem

Protection

        OUT

        OUT

1

2

3

 

Diagram 2 

4.  AC Input Power Cord (See #1 on Diagram 2) 
 

Provides power to your UPS. 

 
5.  Phone/ Fax/ Modem Surge Protection (See #2 on Diagram 2) 

The Phone/ Fax/Modem lines are surge protected. There is one input 
jack and two output jacks.   
 

6.    AC Breaker (Circuit Breaker; See #3 on Diagram 2) 

Should a power overload occur, the circuit breaker will trigger the 
UPS to turn off AC power.   
 

Side Panel B 

 

 

 

 

 

 

 

Diagram 3 

7. 

Your UPS features a serial communication port. Installation of the 
cable and software is optional. This allows the UPS to connect to you 
computer. The Sentry Bulldog Software will not work if the UPS is not 
connected to you computer. This does not mean the battery backup 
feature will not work without the software and cable installed. The 
UPS will still provide backup power but you will be unable to utilize 
the data management capabilities of the software. 

 

UPS INSTALLATION

 

 

1.    Please plug in your UPS without any equipment 

plugged in.   

 

2.  Turn on your UPS by depressing the On/Off button 

for approximately 2 seconds. You will see the 

green indicator light come on. We recommend you 

charge the battery for at least 8 hours prior to full 

use. The battery will not charge unless the UPS is 

turned on.   

 

Should you see the red battery light come on, the 

battery may need charging.   

 

Should the red site wiring fault light come on. 

Please refer to the UPS Features and Functions 

(Chart 1) for the proper reference. 

 

 

3.  Turn off the UPS before installing any products into the UPS or 

Surge outlets. Please be sure all equipment to be installed into 

any of the outlets is turned off. This will ensure that a power 

disturbance will not affect your equipment. 

 

4. 

Plug in only one computer and monitor into the UPS outlets. We 

strongly recommend that only this equipment be plugged into 

the UPS outlets. For all other equipment, plug into the Surge 

outlets. 

 

5.  Plug one end of the phone cable you received into your 

telephone jack and plug the other end into the jack marked IN. 
You may now plug a phone, fax or modem into the two jacks 
marked OUT. (See Diagram 3) 

 

 

Phone

Modem

/ Fax

 

To Telephone Socket

 

Diagram 4 

 

6. 

(Optional) To full utilize the Sentry Bulldog Shutdown Software, 
you will need to connect the UPS to your computer. Connect the 
RJ45 jack to your UPS then connect the serial end to the serial 
port on your computer. 

 

SOFTWARE INSTALLATION

 

(Optional) 

 
1.  Your UPS features the Sentry Bulldog Shutdown Software.   

This allows protects and saves your data should a power 
outage occur. 

 
2.  To install the software, please place the CD into the CD player 

of your computer. 

 
3.  Your computer should automatically run the CD. If this does not 

occur, goto the Run feature on your Start icon (lower left corner) 
on your screen. Please enter the CD drive, it may be D:. Should 
you continue to have a problem, please refer to your computer’s 
owner’s manual for the correct drive. 

 
4.  Once uploaded, please click the Bulldog icon on the screen. 
 
5. 

Click Install Belkin Sentry Bulldog for Win 
95/98/ME/NT4/2000/XP 

 
6. 

InstallShield Wizard will appear onscreen, click Next. 

 
7.  Please read the License Agreement and click Yes. 
 
8.  On Setup Type, click ALL (Standalone). You should not install 

the networking files unless you technically qualified to use these 
features. 

 
9.  On Choose Destination, click Next. 
 
10.  On Select Program Folder, click Next 
 
11.  On Setup Type, please choose your language choice. 
 
12.  The software will now upload. Once completed, please click 

Finish. 

 
13.  Please click the appropriate user’s manual to download. 
 
14.  Click X on the Bulldog setup screen to leave the software setup. 
 
15.  Please refer to the user’s manual for software setup and 

information on software features. 

 

Uninstall for Windows 95/98/Me/NT4/2000/XP 

There are two options to uninstall the Sentry Belkin Shutdown Software. 

1. 

Select the Setup from the BELKIN SENTRY BULLDOG program 
folder and select the remove option to begin the uninstall 
procedure. 

 
2.    Select Add/Remove Programs from the Control Panel and click on 

the BELKIN SENTRY BULLDOG item then press the 
Add/Remove button. 

TECHNICAL SPECIFICATIONS 

 

MODEL 

F6H500-USB 

RATED 

CAPACITY 

500VA /300W 

RATED 

VOLTAGE 

105-135Vac 

INPUT 

PHASE / 

FREQUENCY

Single phase 60HZ 

VOLTAGE 

Step wave 

OUTPUT 

FREQUENCY

60HZ (±1HZ) 

BACK UP 

TIME 

Desktop co17” monitor

13mm 

BATTERY 

RECHARGE 

TIME 

 8hours to 90% 

TEMPERATU

RE 

0~35

 

ENVIRONMEN

HUMIDITY 10~90% 

SAFETY UL1778 

C-UL 

EMI 

FCC CLASS B 

SAFETY 

REGULATION 

EMS 

IEEE C62.41 CATEGORY A 

DIMENSION 

3.14 X 9.84 X 6.6 inches 

APPEARANCE

NET WEIGHT

4.6KGS/ 

10.14LBS 

All specifications are subject to change without prior notice. 

Indicator LED 

Indication 

Description 

 
 

ON-LINE 

О

 Solid green 

AC power is on 

 
 
 

 
 
 
 
 
ON-BATTERY 
and 
LOW-BATTERY 

 Flashing Red 

 

 

The On-Battery and 

Low-Battery LED can 

indicate 1 of 3 conditions: 

 

1.   The UPS is on battery 

backup if the green light 

is off and an intermittent 

audible alarm is on. The 

UPS will begin 

shutdown procedure. 

 

2.   Battery is low. The UPS 

will start shutdown. The 

buzzer sounds an 

audible alarm.   

 

3.   There is a problem with 

the UPS. The LED will 

be lit continuously and 

the buzzer will sound 

audible alarm for 10 

sec. 

 

 
 
 

 

SITE WIRING 

FAULT 

 
 

О

 Solid Red 

The Site Wiring fault LED 
can indicate 1 of 2 possible 
conditions:  
1.   Open or high resistance 

ground 

2.   Hot or neutral polarity 

circuit 

F6H350-SER
F6H500-SER
F6H650-SER
F6H500-USB

R

 

2

22

2

1

11

1

3

33

3

Serial Communication Port

Battery Light

Site Wiring Light

Reviews: