background image

 

0E-1500V8VRD 

 

 

 

 

0E-1000V9VRD 

 

 
 
 

 

 

0E-1000V9VRD and 0E-1500V8VRD 

User

’s Manual 

K01-1101008-00 

 

 

 

(SAVE THESE INSTRUCTIONS) 

This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Please read 

and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, 

or operate. 

CAUTION!   

To  prevent  the  risk  of  fire  or  electric  shock,  install  in  a  temperature  and  humidity  controlled  indoor  area  free  of  conductive 

contaminants.    (Please see specifications for acceptable temperature and humidity range). 

CAUTION!   

To  reduce  the  risk  of  electric  shock,  do  not  remove  the  cover  except  to  service  the  battery.  Turn  off  and  unplug  the  unit  before 

servicing the batteries. There are no user serviceable parts inside except for the battery. 

CAUTION!   

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. 

CAUTION!   

The

 

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do not plug into an outlet that is not 

grounded.    If you need to de-energize this equipment, turn off and unplug the unit. 

CAUTION!   

To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer 

component. 

CAUTION!

    To  reduce  the  risk  of  fire,  connect  only  to  a  circuit  provided  with  20  amperes  maximum  branch  circuit  over  current  protection in 

accordance with the National Electric Code, ANSI/NFPA 70. 

CAUTION!    DO  NOT  USE  FOR  MEDICAL  OR  LIFE  SUPPORT  EQUIPMENT!   

ADI  does  not  sell  UPS  products  for  life  support  or  medical 

applications.   

DO NOT

 use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or 

patient care. 

CAUTION!    DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or near an aquarium.

   

Condensation from the aquarium can cause the unit to short out. 

CAUTION!    DO NOT USE THE UPS ON ANY TRANSPORTATION!   

To reduce the risk of fire or electric shock, do not use the unit on any 

transportation such as airplanes or ships.

 

The effect of shock or vibration caused during transit and the damp environment can cause the unit to 

short out. 

 

 

 

 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following: 

(a) UPS unit (b) 

User’s manual (c) USB A+B type cable (d) Software download card 

 

 

OVERVIEW

 

The

 

UPS provides complete power protection from utility power that is not always consistent. The 

0E-1000V9VRD and 0E-1500V8VRD features 1080 and1500 Joules of surge protection respectively. The 

units provide long lasting battery backup during power outages with maintenance free batteries.   

 
 

AUTOMATIC VOLTAGE REGULATOR

 

The 0E-1000V9VRD and 0E-1500V8VRD stabilizes inconsistent utility power to nominal levels that are safe 

for equipment. Unstable utility power can be damaging to important data and hardware. With Automatic 

Voltage Regulation (AVR), damaging voltage levels are corrected to safe levels.    AVR automatically 

increases low utility power to a consistent and safe 110/120 volts. 

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

 

1.  Ensure that the equipment plugged into the 

outlet does not exceed the UPS unit’s rated capacity 

(1000VA/600W for 0E-1000V9VRD and 1500VA/900W for 0E-1500V8VRD).    If the rated capacities of 

the unit are exceeded, an overload condition may occur and cause the UPS unit to shut down or the 

circuit breaker to trip.     

2.  There are many factors that can affect the amount of power that your computer system will require.    It is 

suggested that the load placed on the battery outlets not exceed 80% of the unit

’s capacity. 

 

HARDWARE INSTALLATION GUIDE 

1.  Your new UPS may be used immediately upon receipt. However, to ensure the battery

’s maximum charge 

capacity, it is recommended that you charge the battery for at least 8 hours. Your UPS is equipped with an 

auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically charge 

whether the UPS is turned on or off. 

2.  With the UPS unit turned off and unplugged, connect your computer, monitor, and any other

 

peripherals 

requiring battery backup into the battery power supplied outlets. 

DO NOT plug a laser printer, paper shredder, copier, space heater, 

vacuum, sump pump or other large electrical devices into the 

“Battery and Surge Protected Outlets”. The power demands of these 

devices may overload and damage the unit. 

3.  To protect a fax, phone or modem, connect a telephone cable or network cable from the wall jack outlet to the IN   

jack of the UPS. Connect a telephone cable or network cable from the OUT jack of the UPS to a fax machine,   

telephone, modem, or network devices. 

4.  Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet).    Make sure the wall branch outlet is   

protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air   

conditioner, 

copier, etc…).    The warranty prohibits the use of extension cords, outlet strips, and surge strips. 

5.  Press the power switch to turn the unit on.    The Power On indicator light will illumin

ate and the unit will “beep”. 

If an overload is detected, an audible alarm will sound and the unit will emit one long beep.    To correct this, turn the UPS off and unplug at 

least one piece of equipment from the battery power supplied outlets.    Make sure the circuit breaker is depressed and then turn the UPS on. 

6.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

7.  To store the UPS for an extended period, cover it and store with the battery fully charged.    While in storage, recharge the battery every three 

months to ensure battery life. 

8.  Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility. 

 

 
 

DESCRIPTION 

 

 

 

 

 

 

 

 

 

 

 

Power Switch   

Press the power button to turn the UPS ON or OFF. 

Power On Indicator 

This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.   

LCD module display 

LCD display shows all the UPS information using icons and messages.    For more information please review the 

“Definitions for Illuminated 

LCD Indicators

” section. 

LCD Display Toggle/Selected Switch 

The switch can be used to select the LCD display contents including Input Voltage, Output Voltage, and Estimated Run Time. The toggle 

frequency is set to one time per second. Holding the switch for more than two seconds while running on battery will silence the alarm. 

Battery and Surge Protected Outlets 

The UPS has

 

battery powered/surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your 

devices during a power failure. 

(DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other 

large electrical devices into the 

“Battery and Surge Protected Outlets”. The power demands of these devices may overload and 

damage the unit.)

 

Full-Time Surge Protection Outlets 

The UPS has surge suppression only outlets to provide protection from surges and spikes. 

Wiring Fault Indicator 

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.    If 

this is illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The unit will 

not provide surge protection without being plugged into a grounded and properly wired wall outlet. 

Communication Protection Ports 

Communication protection ports will protect any standard modem, fax, telephone line, network or Ethernet connection (RJ11/RJ45). 

Circuit Breaker 

Located on the back of the UPS, the circuit breaker provides overload and fault protection.   

10  Serial/USB Ports to PC 

The ports allow connection and communication between the USB/DB-9 port on the computer and the UPS unit. Note: Only one of these two 

ports can be used to communicate with your computer at a time. 

11  Coax/Cable/DSS Surge Protection 

The Coax/Cable/DSS protection ports will protect any cable modem, CATV converter, or DSS receiver. 

12  Outlet Designed for AC Adapters 

The UPS has one outlet with spacing to allow AC power adapters to be plugged into the UPS without blocking adjacent outlets. 

13  Input Power Cord 

Connect the UPS into an AC outlet. 

REPLACING THE BATTERY 

CAUTION!

 Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Service the battery under the supervision of 

personnel knowledgeable of batteries and their precautions. 

CAUTION!

 Use only the specified type of battery. See your dealer for replacement batteries. 

CAUTION!

 The battery may present a risk of electrical shock. Do not dispose of battery in a fire as it may explode. Follow all local ordinances 

regarding proper disposal of batteries. Almost any retailer that sells lead-acid batteries collects used batteries for recycling, as required by most 

state laws. 

CAUTION!

 Do not open or mutilate the batteries. Released electrolyte is harmful to skin and eyes and may be toxic. 

CAUTION! 

A battery can present a high risk of short circuit current and electrical shock. Take the following precautions before replacing the 

battery: 

1. 

Remove all watches, rings or other metal objects. 

2. 

Only use tools with insulated handles. 

3. 

Do not lay tools or metal parts on top of battery or any terminals. 

4. 

Wear rubber gloves and boots. 

5. 

Determine if the battery is inadvertently grounded. If grounded, remove the source of ground. 

CONTACT WITH GROUNDED BATTERY 

CAN RESULT IN ELECTRICAL SHOCK!

 

 

BATTERY REPLACEMENT PROCEDURE: 

1. 

Turn off and unplug all connected equipment. 

2. 

Turn the UPS off and unplug it from the AC power source. 

3. 

Turn the UPS upside down. 

4. 

Remove the retaining screw. 

5. 

Slide the battery compartment cover completely off of the unit. 

6. 

Remove the batteries from the compartment. 

7. 

Disconnect the battery wires from the batteries. 

8. 

Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same color connectors from the battery pack. 

9. 

Put the batteries back into the compartment. 

10. 

Slide back the battery compartment cover and tighten the retaining screws. 

11. 

Recharge the UPS for 8-16 hours to fully charge the battery. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REMINDER:   

Batteries are considered 

HAZARDOUS WASTE

 and must be disposed of properly.    Most retailers that sell lead-acid batteries 

collect used batteries for recycling, as required by local regulations. 

 

 

 

 

Power ON 

 

Wiring Fault 

 

Alarm 

CONDITION 

On 

Off 

Off 

Normal 

On 

Off 

Beeps twice   

every 30 seconds 

Utility Failure- 

The UPS is providing power to battery power-supplied 

outlets from its battery. 

On 

Off 

Rapid Beeping 

every 1/2 second 

Utility Failure-

 The UPS is providing battery power.    Rapid beeping 

indicates the unit will run out of power shortly. 

Off 

Off 

Constant tone 

Overload  -

  Occurs  when  connected  equipment  exceeds  the  listed 

capacity of the UPS.    Turn the UPS off, unplug at least one piece of 

equipment  from  battery  outlets,  wait  10  seconds,  reset  the  circuit 

breaker and turn the unit on. 

On/Off 

On 

None 

Electrical Wiring Fault - 

This 

indicates a wiring problem with the 

AC  outlet

  such  as  bad  ground,  missing  ground,  or  reversed  wiring.   

Disconnect  all  electrical  equipment  from  the  outlet  and  have  an 

electrician check the outlet to insure proper wiring. 

 

 

1. 

INPUT voltage meter: 

This meter measures the AC voltage that the 

UPS system is receiving from the utility wall 

outlet. The UPS is designed, through the use of 

automatic voltage regulation, to continuously 

correct output voltage to connected equipment to 

a safe 110/120 voltage output range. In the event 

of a complete power loss, severe brownout, or 

over-voltage, the UPS relies on its internal 

battery to supply consistent 110/120 output 

voltage. The INPUT voltage meter can be used 

as a diagnostic tool to identify poor-quality input power.

 

2. 

OUTPUT voltage meter: 

This meter measures, in real time, the AC voltage that the UPS system is providing to the computer, such as normal line mode, AVR mode, 

and battery backup mode. (Note: The OUTPUT voltage meter shows the status of the battery backup outlets.) 

3. 

ESTIMATED RUNTIME: 

This displays the run time estimate of the UPS with current battery capacity and load. 

4. 

NORMAL icon: 

This icon appears when the UPS is working under normal conditions. 

5. 

BATTERY icon: 

During a severe brownout or blackout, this icon appears and an alarm sounds (two short beeps followed by a pause) to indicate the UPS is 

operating from its internal batteries. During a prolonged brownout or blackout, the alarm will sound continuously to indicate 

the UPS’s 

batteries are nearly out of power. You should save files and turn off your equipment immediately or allow the software to shut the system 

 

BASIC OPERATION 

INSTALLING YOUR UPS SYSTEM 

IMPORTANT SAFETY WARNINGS 

DEFINITIONS FOR ILLUMINATED LCD INDICATORS 

 

 

 

DEFINITIONS FOR ILLUMINATED LED INDICATORS 

 

0E-1000V9VRD 

0E-1500V8VRD 

0E-1000V9VRD 

 

 

0E-1500V8VRD 