INTRODUCTION

This UPS is specially aimed for use with multi function 

Personal Computers. It is designed to be light weight and 

compact to fit perfectly into a working environment with 

limited space. The ‘Active’ UPS is equipped with boost 

and buck AVR to stabilise the input voltage range. It also 

comes with a built in DC start up function. This function 

enables the UPS to be started up without a supply of 

AC power. Although it is a small UPS, it is also equipped 

with a Smart USB Communication Port to offer the user 

more benefits. The download software facility enables the 

user to monitor the UPS inside status. The main features 

of this ‘Active’ Battery Back Up UPS are listed below:

  • Microprocessor control guarantees high reliability.

  • Equipped with Boost and Buck AVR.

  • Built-in USB Communication Port.

   •  Free Software Download from the Internet.  

(Please check Free Software Download in 

Installation & Operation for detailed information).

  • Green Power Function for energy saving.

  • DC Start Function.

  • Auto restart during AC recovery.

  • Compact size, Light Weight.

  • Provides Modem/Phoneline surge protection.

INSTALLATION AND OPERATION

1.   Inspection

   Remove the UPS from its packaging and inspect 

it for damage that may have occurred during 
shipping. If any damage is discovered, repack the 
unit and return it to the place of purchase.

2.  Charging

   This unit is shipped from the factory with its internal 

battery fully charged, however, some charge may be lost 
during shipping and the battery should be recharged 
prior to use. Plug the unit into an appropriate power 
supply and allow the UPS to charge fully by leaving it 
plugged in for at least 8 hours with no load (no electrical 
devices such as computers, monitors, etc.) connected.

3.  Placement

   Install the UPS unit in any protected environment that 

provides adequate airflow around the unit, and is free 
from excessive dust, corrosive fumes and conductive 
contaminants. Do not operate your UPS in an environment 
where the ambient temperature or humidity is high. 
Also ensure that the UPS unit is placed at least 20cm 
away from your PC monitor, to avoid interference.

4.  Computer and Office Machine 

   Any computers, monitors, or other computer-

related devices should be plugged into either of the 
three (3) power receptacles for battery backup. 

5.  Modem/Phoneline Connection

   Plug incoming telephone line and adaptor into the “IN” 

socket at the back of the UPS. Use one more telephone 
line adaptor and cable to connect the telephone line 
cable to the “OUT” socket at the back of the UPS.  
Plug the other end to the modem input socket. 

6.  Turn On/Off

   To turn on the UPS unit, press the power switch lightly.  

To turn off the UPS unit, press the power switch again. 

7.  DC Start

   Each Battery Back Up model is equipped with a DC 

start function. To start the UPS when AC utility power 
is not available, simply press the power switch.

8.  Green Power Function

   Each Battery Back Up model is equipped with 

a Green Power function. For saving power and 
protecting battery, the method of deep discharging 
protection is adopted on inverter mode.

9.  Free Download Software – WinPower

  •   Go to the website: http://www.ups-software-

download.com/winpower.htm 

  •   Choose the operation system you need 

and follow the instruction described on the 
website to download the software.

  •   When downloading all required files from the 

internet, enter the serial No: 511C1-01220-
0100-478DF2A to install the software.

Note:

  

The Power Switch must be kept in the ‘ON’ position, 
otherwise the UPS will be disabled and your equipment 
will not be protected during a power failure.

 

SYSTEM DESCRIPTION

Front panel:

1.   Power Switch

2.   LED Indicators –  

AC Mode: Green lighting

  Battery Mode: Green flashing

Back Panel

1.  Output receptacles

2.  AC input with AC fuse

3.  RJ11 Modem/Phoneline Surge Protection

4.  USB Communication Port 

TROUBLE SHOOTING

Plu

SPECIFICATION

CONTACT BELKIN

To contact Belkin for any reason, please find our 

international office contact information below.

Belkin Tech Support
UK: 0845 607 77 87

Belkin Ltd.
Express Business Park
Shipton Way, Rushden, NN10 6GL, United Kingdom
+44 (0) 1933 35 2000
+44 (0) 1933 31 2000 fax

Belkin B.V.
Boeing Avenue 333
1119 PH Schiphol-Rijk, The Netherlands
+31 (0) 20 654 7300
+31 (0) 20 654 7349 fax

Belkin GmbH
Hanebergstrasse 2
80637 Munich, Germany
+49 (0) 89 143405 0 
+49 (0) 89 143405 100 fax

Belkin SAS
130 rue de Silly
92100 Boulogne-Billancourt, France
+33 (0) 1 41 03 14 40
+33 (0) 1 41 31 01 72 fax

Belkin Nordic
Knarrarnäsgatan 7
164 40  Kista, Sweden
+46 (0) 8 5229 1870
+46 (0) 8 5229 1874 fax

Belkin Ltd.
7 Bowen Cresent, West Gosford
NSW 2250, Australia
+61 (0) 2 4372 8600
+61 (0) 2 4372 8603 fax

Symptom

Possible Cause

Remedy

No LED 

display on 

the front 

panel.

1. Battery weak.

1.  Re-charge 

battery up to 

8 hours.

2. Battery defect.

2.  Replace with 

the same type   

of battery.

3.  Power switch is 

not pressed.

3.  Press the power 

switch again.

Alarm buzzer 

beeps 

continuously 

when AC 

supply is 

normal.

Overload of the UPS.

Verify that the load 

matches the UPS 

capability specified 

in the specs.

When power 

failure, back-

up time is 

shortened.

1.  Overload of 

the UPS.

1.  Remove some 

noncritical load.

2.  Battery voltage 

is too low.

2.  Charge battery 8 

hours or more.

3.  Battery defect due 

to high temperature 

operation 

environment, or 

improper operation 

to battery.

3.  Replace with 

the same type 

of battery.

Mains normal 

but LED is 

flashing.

1. Fuse is blown.

1.  Replace the same 

type of fuse.

2.  Power cord 

is loose.

2.  Reconnect the 

power cord 

properly.

If any abnormal situations occur that are not listed 

above, please call service people immediately.

MODEL

Active Bat-

tery Back 

Up 400VA

Active Bat-

tery Back 

Up 600VA

Active Bat-

tery Back 

Up 800VA

CAPACITY 

VA/W

400VA/

240W

600VA/

360W

800VA/

480W

INPUT

Voltage

230VAC

Voltage Range

170-280VAC or 162-290VAC

Frequency 

45-65 Hz (Auto Sensing)

OUTPUT

Voltage

230VAC

Voltage 

Regulation 

(Batt. Mode)

+/-10%

Frequency

50Hz or 60Hz

Frequency 

Regulation 

(Batt. Mode)

+/-1 Hz

Output 

Waveform

Modified Sinewave

BATTERY

Battery Type

12V4.5Ah x 1  12V7Ah x 1 12V9Ah x 1

Backup Time 

(at a PC load 

with 15” 

monitor)

10 to 12 

minutes

20 to 22 

minutes

28 to 30 

minutes

Recharge 

Time

8 hours to 90% after  

complete discharge

TRANSFER 
TIME

Typical

2-6 ms

INDICATOR

AC Mode

Green lighting

Backup Mode

Green flashing

AUDIBLE 
ALARM

Backup Mode

Sounding every 10 seconds

Low Battery

Sounding every second

Overload

Sounding every 0.5 second

Battery Re-

placement

Sounding every 2 seconds

Fault

Continuously sounding

PROTECTION

Full Protection

Discharge, overcharge, and 

overload protection

PHYSICAL

Dimension 

(mm), DXWXH

330X100X140

WEIGHT

Net Weight

5kgs

6kgs

6.5kgs

ENVIRONMENT

Operating 

Environment

0- 40°C, 0-90 % relative  

humidity (non-condensing)

Noise Level

Less than 40dB

INTERFACE

USB Port 

Windows 98/2000/ME/XP/Vista

UK