Belinea 101910
SAFETY PRECAUTIONS
1. CAUTION:
No modification of any circuit should be attempted. Service work should only be performed after you
are through familiar with all of the following safety checks and servicing guide lines.
2. SAFETY CHECK
Care should be taken while servicing this LCD display. Beware of the high voltage used in the inverter
circuit. These voltages are exposed in such areas as the associated transformer circuits.
3. POWER SUPPLY REQUIREMENTS
The internal power converter for this display utilizes an AC cord. The AC cord is detachable.
Any attempt to replace another adapter could result in serious problem on the display.
4. LEAKAGE CURRENT HOT CHECK
4-1
Plug the AC cord directly into the AC outlet. Do not use an isolation transformer during this check.
4-2
Connect a 1500 ohm, 10 watt resistor, paralleled by a 0.15uF capacitor between each metallic part
and a good earth ground.
4-3
Use an AC voltmeter with 1000 ohm / volt or more sensitivity and measure the AC voltage across
the combination 1500 ohm resistor and 0.15uF capacitor.
4-4
Move the resistor connection to each exposed metallic part and measure the voltage.
4-5
Reverse the polarity of the AC plug in the AC outlet and repeat the above measurement.
4-6
Voltage measured must not exceed 1.5 volt RMS, from any exposed metallic part to the ground.
A leakage current tester may be used in the above hot check, in which case any circuit measured
must not exceed 1 milliamp. In the case of a measurement exceeding the 1 milliamp value, a
rework is required to eliminate the chance of a shock hazard.
To Metal Parts
V
AC VOLTMETER
1500
10W
0.15u
.
Earth Ground
MAXDATA Servicemanual 111908 Page
4
- Confidential -
Summary of Contents for 101910
Page 6: ...Belinea 101910 1 3 Rear View 1 4 Side View MAXDATA Servicemanual 111908 Page 6 Confidential...
Page 37: ...Belinea 101910 MAXDATA Servicemanual 111908 Page 37 Confidential...
Page 38: ...Belinea 101910 Button Board Silkscreen MAXDATA Servicemanual 111908 Page 38 Confidential...
Page 46: ...10 SCHEMATIC DIAGRAM POWER DB Page 46...
Page 47: ...Page 47...
Page 48: ......
Page 49: ......
Page 50: ...Page 50...
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......