WIRING DIAGRAMS
QUICK MOUNT VISUAL INSTRUCTION MANUAL
UGVL Linkage with LVK and SVK Series Actuators
BL
K
Bl
ac
k
Ne
g
ro
No
ir
Pr
eto
RED
Re
d
Ro
jo
R
ouge
Ve
rm
el
h
o
WHT
Wh
ite
Bl
an
co
Bl
an
c
Br
an
co
PNK
Pi
nk
Ro
sa
d
o
Ro
sa
Co
r-
d
e r
os
OR
G
Ora
n
g
e
A
n
aran
jado
Ora
n
g
e
A
laran
jado
BL
U
Bl
u
e
Az
ul
Bl
eu
Az
ul
BR
N
Br
ow
n
Ma
rr
on
Bru
n
Ma
rr
om
Electronic Fail-Safe Actuator with -3 and -SR
2
3
24 VAC Transformer
Blk (1) Common
Red (2) + Hot
Wht (3) +
Line
Volts
–
18
Y input
1
Pnk
(4)
18
Blk (1) Common
Red (2) + Hot
Wht (3)
Y Input,
2 to 10V
Org (5)
U Output,
2 to 10V
24 VAC Transformer
5
7
Control Signal
(+)
VDC/mA
(–)
Feedback Signal (+)
2 to 10 VDC
(–)
Ω
500
Ω
Line
Volts
3
18
On/Off
Floating Point
VDC / 4 to 20 mA
2
100 to 240 VAC
Blu (1) Common
Brn (2) +
Wht (3) +
N L1
H L2
–
A
Line
Hot
2
100 to 240 VAC
Blu (1) Common
Brn (2) +
Wht (3) +
N L1
H L2
A
Line
Hot
On/Off
Floating Point
Blk
(1)
Common
Red
(2)
+ Hot
Wht
(3)
Y
1
Input
Pnk
(4)
Y
2
Input
Com
Hot
Controller
Line
Volts
10
24 VAC Transformer
5
18
18
Blk
(1)
Common
Red
(2)
+ Hot
Wht
(3)
Y
1
Input
Pnk
(4)
Y
2
Input
Com
Hot
Controller
Line
Volts
24 VAC Transformer
18
10
Blk
(1)
Common
Red
(2)
+ Hot
Wht
(3)
Y
1
Input
Pnk
(4)
Y
2
Input
Com
Hot
Controller
Line
Volts
24 VAC Transformer
Line
Volts
24 VAC Transformer
Triac Sink
Triac Source
Triac Sink with Separate Transformer
Electronic Fail-Safe Actuator with MFT
18
Blk
(1)
Common
Red
(2)
Hot
Wht
(3)
Y Input
Org
(5)
U Output
Line
Volts
24 VAC Transformer
2 to 10 VDC
Feedback Signal (+)
(–)
3
Line
Volts
(–)
(+)
24 VAC Transformer
Blk (1) – Common
Red (2) + Hot
Wht (3) Y
1
Input
Org (5) U Output 2 to 10V
A
B
18
A
B
Direction of rotation switch
A
B
2
9
8
10
12
Feedback Signal
2 to 10 VDC
18
18
Notes:
On/Off
Floating Point
7
Blk
(1)
Common
Red
(2)
+ Hot
Wht
(3)
Y
1
Input, 2 to 10V
Org
(5)
U Output, 2 to 10V
(–)
(+)
Line
Volts
24 VAC Transformer
Ω
500
Ω
1/4 watt
3
18
Control Signal
VDC/mA
18
Functions
0%
50%
100%
Control mode acc. to Y
Min*
Mid*
Max*
Normal**
* Default selectable 0-100%. See Configuration Data Sheet.
** Customizable. See Configuration Data Sheet.
a
b
c
500
Ω
Ω
Blk
(1)
Common
Red
(2)
+ Hot
Org
(5)
Wht
(3)
Y
1
Input, 2 to 10V
(–)
(+)
Line
Volts
24 VAC Transformer (AC Only)
7
B
C
A
1/4 watt
VDC/mA
Control Signal
VDC / 4 to 20 mA
Override Control Min, Mid, Max Postions
Meets cULus requirements without the need of an
electrical ground connection
A
Actuators with appliance cables are numbered.
2
Actuators may be connected in parallel. Power
consumption and input impedance must be observed.
3
Actuators may also be powered by 24 VDC.
5
Only connect common to neg. (-) leg of control circuits.
7
A 500 Ω resistor converts the 4 to 20 mA control signal
to 2 to 10 VDC.
8
Control signal may be pulsed from either the Hot
(Source) or Common (Sink) 24 VAC line.
9
Contact closures A & B also can be triacs. A & B should
both be closed for the triac source and open for triac
sink.
10
For triac sink the Common connection from the actuator
must be connected to the Hot connection of the
controller. Position feedback cannot be used with a triac
sink controller. The actuator internal common reference
is not compatible.
12
12
IN4004 or IN4007 diode. (IN4007 supplied, Belimo Part
number 40155)
18
Actuators with plenum rated cable do not have numbers
on wires; use color codes instead.