Figure 9 - Stove - Exploded view

Exploded view

Ref. 154 05 12

Gas stove "Belfort"

Technical manual

11

Summary of Contents for 154 05 12

Page 1: ... Belges 59660 MERVILLE Phone 03 28 43 43 43 Fax 03 28 43 43 99 RC Hazebrouck 445750565B Subject to modifications Belfort Gas stove EN 613 Model 154 05 12 Propane type G31 Category I 3P Français English Description of the appliance Installation instructions Operating instructions Spare parts Warranty certificate ...

Page 2: ...3 Installation instructions 4 Siting the appliance 4 Clearance requirements 4 Hearth 4 Flue connection 5 Smoke exit on the top 5 Smoke exit at rear 5 Ventilation G B Only 5 Connecting the gas supply 5 Pressure testing 5 Coals layout 6 Test for spillage 7 Service section 7 Troubleshooting chart 7 Servicing instructions 7 User instructions 8 Important Notes 8 Data information 8 Arranging the layout ...

Page 3: ...er to your home Providing a highly efficient heat source the Belfort has the look and charm of a real stove coupled with the convenience of clean burning gas The stove is designed to run LPG gas It is important to note that once a type of gas has been specified the stove cannot run off any other type The type of gas which your stove is capable of burning is stated on the data information panel See...

Page 4: ... single or double walled pipe of 126 mm diameter 2 1 1 Clearance requirements If the appliance has to be located in an opening there must be a clearance of at least 50 mm at the left hand of the appliance 50 mm at the back of the appliance and 50 mm above from any non combustible materials as shown in figure 2 This distance must be extended to a mininum clearance of 80 mm from any combustible mate...

Page 5: ...outer diameter of 139 mm 2 2 1 Smoke exit on the top Figure 3 Remove the top plate first remove the 2 screws on the sides of the appliance Fit the sealing rope in the groove and attach the flue spigot using the three bolts and washers supplied Check that the two blanking plates are fixed to the back wall Refit the top plate ensuring there is a good seal 2 2 2 Smoke exit at rear Figure 4 Remove the...

Page 6: ...mics Instructions for the layout of the prefixed ceramic matrix and loose coals for Belfort fitted with gas burner unit Parts 1 Ceramic mat 9 Ceramic coals Figure 5 Place the ceramic matrix rep 3 above the ceramic mat on the supports onto the top of the burner body Figure 6 Place 4 coals on top of the matrix A as shown in B Place the remaining 5 coals as shown in C 1 2 3 5 4 3 3 A B C Figure 5 Fit...

Page 7: ...s out when the handle is turned from the ignite position to the pilot light position The thermocouple is not at a high enough temperature the pilot light flame is too short Check that the injector rep 10 fig 9 p 10 is not partially blocked To gain access to the injector the coals and the burner must first be dismounted 3 screws Bad contact at the connection of the thermocouple to the valve Check t...

Page 8: ... coal layout given in the installer instructions DO NOT OBSTRUCT THE PILOT FRANCO BELGE accept no responsibility for any injury sustained whilst handling hot ceramics 3 4 Operating the stove The Belfort gas stove operates with a traditional permanent pilot light The knob for ignition and power control is located on the lower right hand side of the stove fig 8 The pilot light is located at the fron...

Page 9: ... both with the presence of water or absence of mains supply The Belfort has a Piezo ignition which requires no external power source The piezo works on the same principle as a cigarette lighter providing a spark when required 3 6 Cleaning Ensure that the stove is turned off before cleaning and do not attempt to clean if the unit is still hot The coals within the appliance are manufactured from hig...

Page 10: ...67x205 A B C D 01 27 189825 Screw M5x6 A B C D 01 28 189849 Screw M6x16 A B C D 01 29 236007 Burner plate A B C D 01 30 243404 Draught diverter A B C D 01 31 243505 Supplementary diverter A B C D 01 32 259015 Fixing plate A B C D 04 33 276006 Plate A B C D 01 34 300118 MJ Leg C 04 34 300118 MK Leg D 04 34 300118 EF Leg A 04 34 300118 79 Leg B 04 35 300480 Base A B C D 01 36 301541 MJ Door lock C 0...

Page 11: ...3 1 3 2 3 4 3 5 3 6 3 7 3 8 3 9 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 5 1 5 2 5 4 5 5 3 4 4 2 4 2 4 2 1 2 1 2 9 5 0 5 4 9 2 7 3 4 3 4 3 4 4 0 1 4 1 8 1 7 1 5 6 5 7 3 3 5 8 5 6 5 3 Figure 9 Stove Exploded view Exploded view Ref 154 05 12 Gas stove Belfort Technical manual 11 ...

Page 12: ...2 60 Injector support LPG A B C D 01 51 982644 Pilot line A B C D 01 52 982646 Feed line regulator burner A B C D 01 53 905927 Complete burner LPG A B C D 01 54 905926 Burner LPG A B C D 01 55 149862 Knob A B C D 01 56 109724 Ceramic coal A B C D 05 57 124412 Strut A B C D 01 58 158272 Control plate A B C D 01 List of components Gas stove Belfort Ref 154 05 12 12 Technical manual ...

Page 13: ...Notes Ref 154 05 12 Gas stove Belfort Technical manual 13 ...

Page 14: ... Any damage resulting from the use of fuel not recommended in our instructions Parts which are damaged by external causes such as unadapted chimneys thunderstorms damp faulty pressure or fail in pressure thermic anomalies explosions etc Electrical parts which are deteriorated by any connection or use on a supply circuit with voltage within 10 of the indicted voltage 230 V in EU Material subject to...