
Technical Manual
0970 PSL 700 | 0970 PSL 701
Version 1.21 / 24.09.2014
Specifications subject to alteration!
Page 16 of 17
The reverse polarity protection only works if the actuator sys
tem power supply is protected by a current overload fuse (10
A, mT) and switches off no later than 10
–
100 ms after a short
circuit has occurred.
Info 1:
The outputs are able to switch currents of 1.6 A with a
frequency of 1 Hz with inductive loads of the
utilization category DC13 (EN6094751).
Info 2:
Test proven and approved under the following conditi
ons:
looped through System/Sensor power supply max. 2.5 A
Power supply cable STL 204 (5 x 1 mm²)
Operating temperature range max. 40°C
max. output current 12 A
NOTE!
A power pack with current regulation or an incorrect fuse
will result in the destruction of the module in the event of
reverse polarity.
5. Technical data
5.1 General data
Degree of protection
IP 67 (only in locked position)
Operating temperature range
10°C / +60°C
Weight
380 g
Housing
PBT
Vibration resistance oscillations
15 g / 5–500 Hz
Vibration resistance shocks
50 g / 11 ms
Torques
Fastening screw M4
1.0 Nm
Connector M12
0.6 Nm
5.2 Technical data – Bus system
Protocol
Profibus DP
ID no.
09CA hex
GSD file
Lum_09CA.gsd
Data transmission rates
9,6 / 19,2 / 45,45 / 93,75 /
187,5 / 500 KBit/s
1,5 / 3,0 / 6,0 / 12,0 MBit/s
Adjustment of the data
automatic at the start of
transmission rate
communications
Address range:
Adjustment via Profibus:
1–126 dec
(address switch: "00")
Adjustment via address switch:
1–99 dec
Default address
99 dec
Please see chapter 4.1:
Addressing
Connection
M12 male/female connector,
5 poles; please see pin
assignment
5.3 Technical data power supply –
Electronics/Sensors
Rated voltage U
S
24 V DC
Voltage range
19–30 V DC
Power consumption Electronics
typ. 70 mA
Voltage Sensors
min. ( U
System
1.5 V)
Power consumption Sensors
max. 200 mA (at Tu 30°C)
Reverse polarity protection
yes
Indication (U
S
)
LED green
Connection
7/8" male/female connector,
(5 poles, please see pin
assignment
5.4 Technical data power supply – Actuators
Rated voltage U
L
24 V DC
Voltage range
19–30 V DC
Galvanic separation
yes
Undervoltage threshold
typ. 17 V
Delay time
Undervoltage detection
< 20 ms
Reverse polarity protection
yes
Indication Actuator supply U
L
LED green
Connection
7/8" male/female connector,
5 poles; please see pin
assignment
5.5 Technical data – Inputs
Input circuit
Type 3 according to
IEC 611312
Rated input voltage
24 V DC
Input current at 24 V DC
typ. 5 mA
Shortcircuit proof
yes
Channel type N.O.
pswitching
Number of digital channels
16
Status indication
LED yellow per channel
Diagnostic indication
LED green per socket
Connection
M12 female connector, 5 poles;
please see pin assignment
5.6Technical data – Outputs
Output circuit
Type 1.6 A according to
IEC 611312
Rated output current per channel:
1.6 A, please see Info 1
Signal state "1"
max. 1.9 A
Signal state "0"
max. 1 mA (according to
specification)
Signal level of the outputs
Signal state "1"
min. (U
L
1 V)
Signal state "0"
max. 2 V
Shortcircuit proof
yes
Max. output current per module
9.0 A, please see Info 2
Overloadproof
yes
Number of digital channels
16
Channel type N.O.
pswitching
Status indication
LED yellow per channel
Diagnostic indication
LED red per channel/socket
Connection
M12 female connector, 5 poles;
please see pin assignment