Installation SPIDER-SL PoE
22
Release 01 05/2019
2.5
Wiring the terminal block for the supply
voltage and the grounding
WARNING
ELECTRIC SHOCK
Connect only a supply voltage that corresponds to the type plate of
your device.
Never insert sharp objects (small screwdrivers, wires, etc.) into the
connection terminals for the supply voltage, and do not touch the
terminals.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
A 4-pin terminal block is used for connecting the supply voltage and it is
a redundant power.
A grounded screw is used for the grounding.
Figure 1: 4-pin, pluggable terminal block for power supply
Type of the
voltages that can
be connected
Specification of the
supply voltage
Connections
DC voltage
Rated voltage range DC
12 V ... 57V
+
Plus terminal of the supply
voltage
-
Minus terminal of the supply
voltage
Table 2: Type and specification of the supply voltage and pin assignment on the device
The operating voltage can be connected redundantly. Both inputs are
uncoupled. There is no distributed load. With redundant supply, the
power supply unit with the higher output voltage supplies the device
on its own.