Installation RS20/22/30/32/40
Release 07 10/2021
To mount the device onto a horizontally mounted 35 mm DIN rail according
to DIN EN 60715, proceed as follows:
Slide the upper snap-in guide of the device into the DIN rail.
Pull the rail lock slide down using a screwdriver, and press the lower part
of the device against the DIN rail.
Snap in the device by releasing the rail lock slide.
Note:
The overall shield of a connected shielded twisted pair cable is
connected to the grounding connector on the front panel as a conductor.
2.2.2
DIN rail mounting on ships (RS30-0802...)
When you are mounting your RS30-0802... Open Rail device on a DIN rail on
ships and in similar applications, the Open Rail Mounting Kit available as an
accessory can be used to avoid excessive resonance.
You must use the Open Rail Mounting Kit with the order number
942 007-001 when mounting your RS30-0802... device on ships.
If you have very little space on your DIN rail, you can alternatively use
Open Rail Mounting Kit 942 007-101 (for mounting DIN rail on DIN rail).
Mount one mounting kit on each side of your RS30-0802... device, but at
least one mounting kit on one side of the RS30-0802... device. If possible,
position one side of the RS30-0802... device on a wall, or in a similarly
stable way. If you are positioning multiple RS30-0802... devices side by
side, mount the row of devices in the way described for a single device.
Mount a standard DIN rail stopper on both sides beside the mounting kit.
For more information on mounting the RS30-0802... on a DIN rail on ships,
see the “Open Rail Mounting Kit Mounting Note” supplied with the Open Rail
Mounting Kit.