18
Installation RED25
Release 01 02/2015
1.5.2
100 Mbit/s F/O port (optional)
This port is an SFP slot.
The 100 Mbit/s F/O port offers you the ability to connect network components
according to the IEEE 802.3 100BASE-FX standard.
This port supports:
Full or half duplex mode
Default setting: Full duplex
1.6
Display elements
After the working voltage is set up, the software starts and initializes itself.
Afterwards, the device performs a self-test. During this process, various
LEDs light up.
1.6.1
Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
LED
Display
Color Activity
Meaning
Power Supply voltage
—
None
Supply voltage is too low
Yellow Lights up
Device variants with redundant power
supply:
Supply voltage 1
or
2 is on
flashes 4 times
a period
Software update is running. Maintain the
power supply.
Green Lights up
Device variants with redundant power
supply:
Supply voltages 1
and
2 are on
Device variants with single power supply:
Supply voltage is on
Status Device Status
—
None
Device is starting and/or is not ready for
operation
Green Lights up
Device is ready for operation.
Characteristics can be configured
Red
Lights up
Device is ready for operation.
Device has detected at least one error in
the monitoring results
Flashes 1 time
a period
The boot parameters used when the
device has been started differ from the
boot parameters saved.
Start the device again.
flashes 4 times
a period
Device has detected a multiple IP address
Status
RM
ACA
Power
Summary of Contents for Hirschmann RED25 Series