background image

2

EN

Manuals and software are protected by copy-

right. All rights reserved. The copying, repro-

duction, translation, conversion into any elec-

tronic medium or machine scannable form is 

not permitted, either in whole or in part. An 

exception is the preparation of a backup copy 

of the software for your own use.

The performance features described here are 

binding only if they have been expressly a-

greed when the contract was made. This doc-

ument was produced by Hirschmann Auto-

mation and Control GmbH according to the 

best of the company's knowledge. 

Hirschmann reserves the right to change the 

contents of this document without prior notice. 

Hirschmann can give no guarantee in respect 

of the correctness or accuracy of the informa-

tion in this document.

Hirschmann can accept no responsibility for 

damages, resulting from the use of the net-

work components or the associated operating 

software. In addition, we refer to the condi-

tions of use specified in the license contract.

You can get the latest version of this manual 

on the Internet at:

https://www.doc.hirschmann.com

© Hirschmann Automation and Control 
GmbH

 

20

22

Certified usage

Please observe the following: 

z

Warning

The device may only be employed
for the purposes described in the
catalog and technical description,
and only in conjunction with exter-
nal devices and components
recommended or approved by 
Hirschmann. The product can only
be operated correctly and safely if
it is transported, stored, installed
and assembled properly and cor-
rectly. Furthermore, it must be
operated and serviced carefully.

z

Safety instructions

Please read carefully this
safety instructions!

Before you start working on the power
module, read the operating instructions
completely. Make sure that you under-
stood everything. Please follow all notes.

– Installation and elimination of errors

have to be made only by electrical quali-
fied persons. Switch all wires to be
mounted idle. Make sure to prevent
unintentional switch-on.

– As long as the unit is activated, it is not

allowed to make any changes of the
installation.

– Operate with the connecting terminals

only without voltage.

– Inside the unit are components and con-

ductors which can store perilous high vol-
tage – also in the case of errors. The inap-
propriate use might result in an electric
shock or serious burns.

7

CE marking

The devices comply with the regula-
tions of the following European

 

directive:

2011/65/EU and 2015/863/EU (RoHS)

Directive of the European Parliament 

and of the Council on the restriction of 

the use of certain hazardous sub-

stances in electrical and electronic 

equipment.

2014/30/EU (EMC)

Directive of the European Parlia-
ment and the council for standardi-
zing the regulations of member

 

states with regard to electromagne-
tic compatibility.

Additional for PC150/72V/48V-IP67:

2014/35/EU

Directive of the European Parliament 

and of the Council on the 

harmonisation of the laws of the 

Member States relating to the making 

available on the market of electrical 

equipment designed for use within 

certain voltage limits.

The EU declaration of conformity is

 

kept available for the responsible

 

authorities in accordance with the

 

above-mentioned EU directives at:

Hirschmann 

Automation and Control GmbH

 

Stuttgarter Straße 45-51
D-72654 Neckartenzlingen

www.hirschmann.com

The product can be used in the resi-
dential sphere (residential sphere,

 

business and trade sphere and small

 

companies) and in the industrial

 

sphere.
– Interference immunity:

EN 61000-6-2

– Radio interference level:

EN 

55032

Security: EN 

61010-1

z

Warning!

This is a Class A device. This equip-
ment may cause radio interference if
used in a residential area; in this
case it is the operator´s responsibili-
ty to take appropriate measures.

The precondition for compliance
with EMC limit values is strict adhe-
rence to the construction guidelines
specified in this description and
operating instructions.

FCC Note:

This device complies with part 15 of FCC
rules. Operation is subject to the following
two conditions: 

– This device may not cause harmful inter-

ference, and

– this device must accept any interference

received, including interference that may
cause undesired operation.

Note:

This equipment has been tested and

found to comply with the limits for a Class
A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to
provide reasonable protection against
harmful interference when the equipment is
operated in a commercial environment.
This equipment generates, uses, and can
radiate radio frequency energy and, if not
installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential
area is likely to cause harmful interference
in which case the user will be required to
correct the interference at his own expense.

,

Recycling Note:

After its use, this product has to be
processed as electronic scrap and
disposed of according to the prevai-
ling waste disposal regulations of
your community / district / country /
state.

CE marking

The devices comply with the regula-
tions of the following

 

directive:

S.I. 2012 No. 3032

Restriction of the Use of Certain Haz-

ardous Substances in Electrical and

Electronical Equipment Regulations
S.I. 2016 No. 1091

Electromagnetic Compatibility

Regulations

Additional for PC150/72V/48V-IP67:

2014/35/EU

S.I. 2016 No. 1101

Electrical Equipment (Safety)

Regulations

The U

KCA

 declaration of conformity is

 

kept

available for the responsible

 

authorities at:

Belden UK Ltd.

1 The Technology Centre, Station Road

Framlingham, IP13 9EZ, United Kingdom

The product can be used in the residential 
sphere (residential sphere,

 

business and 

trade sphere and small

 

companies) and in 

the industrial

 

sphere.

– Interference immunity:

EN 61000-6-2

– Radio interference level:

EN 

55032

Security: EN 

61010-1

z

Warning!

This is a Class A device. This equip-
ment may cause radio interference if
used in a residential area; in this
case it is the operator´s responsibili-
ty to take appropriate measures.

The precondition for compliance
with EMC limit values is strict adhe-
rence to the construction guidelines
specified in this description and
operating instructions.

Summary of Contents for HIRSCHMANN PC150 48V-IP67 Series

Page 1: ...ge of 48 VDC from an input voltage of 72 110 VDC Permitted ambient temperature 40 to 70 C in accordance with EN50155 for max 10 minutes up to 85 C No additional cooling element necessary voltage transformer is integrated into cooling element 150 W power output Class I equipment IP67 enclosure type Conforms to EN50155 class C1 S2 Output has short circuit protection Input has polarity reversal prote...

Page 2: ...al equipment designed for use within certain voltage limits The EU declaration of conformity is kept available for the responsible authorities in accordance with the above mentioned EU directives at Hirschmann Automation and Control GmbH Stuttgarter Straße 45 51 D 72654 Neckartenzlingen www hirschmann com The product can be used in the resi dential sphere residential sphere business and trade sphe...

Page 3: ...ns of the PC150 36V 48V IP67 and PC150 72V 48V IP67 power supply units in mm 1 2 PIN ASSIGNMENTS 2 2 ATTACHING THE FERRITE A ferrite incorporated into the secondary cable is included in the delivery Fig 2 Ferrite mounted on the secondary cable of the device 2 3 CONNECTING THE SUPPLY VOLTAGE AND MOUNTING THE PROTECTIVE CONDUCTOR M Connect the protective conductor see chapter 1 2 Pin assignments bef...

Page 4: ... Class of protection Class I equipment Enclosure type IP 67 Insulation resistance Primary secondary 2000 V AC Primary housing 1000 V AC Secondary housing 1500 V AC Insulation resistance 500 Megaohm Approvals Standards IEC EN 61010 1 VDE 0411 1 IEC EN61131 2 2007 CE Declaration programmable logic controllers EN50155 Class S1 C2 Railway applications electronic systems in railway vehicles environment...

Page 5: ...r input 2 kV line earth IEC EN61000 4 6 Line conducted interference voltages 150 kHz to 80 MHz 10 V Mechanical components Dimensions without cables W x H x L 115 mm x 65 mm x 240 mm Weight 3 100 g Housing material Aluminum UL94 V0 Casting compound Polyurethane Vibration resistance IEC60068 2 6 Test Fc Test level according to IEC61131 2 EN61373 category 1 Class A broadband noise installation accord...

Page 6: ...n Automation and Control GmbH Stuttgarter Straße 45 51 D 72654 Neckartenzlingen Germany www hirschmann com Technical support https hirschmann support belden com Printed in Germany Subject to alterations 04 1122 ...

Reviews: