Installation GRS105/GRS106
Release 01 11/2021
49
For
every
supply voltage to be connected, perform the following work
steps:
Remove the terminal block from the device.
Connect the wires according to the pin assignment on the device with
the clamps.
Fasten the wires in the terminal block by tightening the terminal
screws.
You find the prescribed tightening torque in chapter:
“General technical data” on page 61
6.6.2
Supply voltage characteristic value L
Exclusively supply your device with SELV/ES1 voltage.
You will find information on the characteristic values here:
“Device name and product code” on page 21
You have the option of supplying the supply voltage redundantly, with load
distribution.
Both supply voltage inputs are electrically isolated.
Figure 19: Supply voltage with characteristic value L: 2-pin terminal block with screw
lock
Type of the voltages
that can be connected
Specification of the
supply voltage
Pin assignment
DC voltage
Rated voltage range
110 V DC ... 250 V DC
Voltage range incl.
maximum tolerances
88 V DC ... 288 V DC
+
-
Plus terminal of the supply voltage
Minus terminal of the supply voltage
Protective conductor
Table 14: Supply voltage with characteristic value M: type and specification of the
supply voltage, pin assignment on the device
−
+
Summary of Contents for HIRSCHMANN GRS105
Page 78: ......