![Belden HIRSCHMANN 70914569 User Manual Download Page 23](http://html.mh-extra.com/html/belden/hirschmann-70914569/hirschmann-70914569_user-manual_2725656023.webp)
Installation SPIDER II 16TX
Release 02 12/2014
23
Dimension drawings
EMC and immunity
EMC interference emis-
sion
Radiated emission
FCC 47 CFR Part 15
Class A
EN 55022
Fulfilled
Conducted emission
FCC 47 CFR Part 15
Class A
EN 55022
Fulfilled
EMC interference immu-
nity
Electrostatic discharge
EN 61000-4-2
IEEE C37.90.3
Contact discharge
± 4 kV
EN 61000-4-2
IEEE C37.90.3
Air discharge
± 8 kV
Electromagnetic field
EN 61000-4-3
80 MHz ... 1000 MHz
10 V/m
EN 61000-4-3
1.4 GHz ... 2 GHz
3 V/m
EN 61000-4-3
2 GHz ... 2.7 GHz
1 V/m
Fast transients (burst)
EN 61000-4-4
IEEE C37.90.1
DC supply connection
2 kV
EN 61000-4-4
IEEE C37.90.1
Data line
4 kV
Voltage surges - DC supply connection
2.6
66
120
4.72
4.37
111
8,5
0.33
44
1.73
1.9
48,27
138 5.43
inch