197
Video Settings
Decodable
– This limiter mode produces colors that decode to valid RGB
components. Not all valid RGB colors can be transmitted in NTSC, how-
ever. Saturated colors near yellow and cyan over modulate an NTSC trans-
mitter.
Transmittable
– This limiter mode prevents over modulating an NTSC trans-
mitter, but can produce colors which can not be decoded into RGB. For
example, a 0% luminance blue produces negative green and red compo-
nents.
Both
– This limiter mode is similar to
Decodable
, except that maximum levels
are reduced slightly around yellow and cyan to prevent over modulating
an NTSC transmitter.
Command Processing
These controls determine when commands (like source selections or the
initiation of mixes or wipes) will be enacted by the Kayenne K-Frame
system (also known as field dominance). These controls can be useful for
consistent match frame editing.
Any Field
– The action will occur at the start of the next field, either even or
odd. Use this setting if you are not going to edit the video output and want
the fastest response.
Even Field
– The action will always occur at the start of the next even field.
This is probably only appropriate if your edit controller is set to edit in the
middle of a frame.
Odd Field
– The action will always occur at the start of the next odd field. This
is the normal setting for almost all conditions, especially when the video
output will be edited, and is compatible with most video editing systems
that use the frame boundary for edits. This setting is essential, however,
when controlling external devices like DDRs that execute commands only
at the beginning of the frame.
Output Blanking
Production switchers normally regenerate a clean blanking interval. When
the switcher must pass ancillary information such as embedded audio, this
blanking regeneration can be disabled. This following settings apply to the
output blanking of all the MEs.
Pass Bus A’s Ancillary Data
– Passes the ancillary data from the A bus to the ME
Program output during the vertical interval.
Regenerate Blanking
– Regenerates blanking during the vertical and hori-
zontal intervals.
Summary of Contents for Grass Valley Kayenne K-Frame
Page 2: ......
Page 30: ...30 KAYENNE K FRAME Installation Service Manual Regulatory Notices ...
Page 42: ...42 KAYENNE K FRAME Installation Service Manual Section 1 Introduction ...
Page 108: ...108 KAYENNE K FRAME Installation Service Manual Section 4 System Cabling ...
Page 208: ...208 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration ...
Page 270: ...270 KAYENNE K FRAME Installation Service Manual Maintenance ...