Replacing Frame Ventilation Fans
The main cooling fans on the rear of Densité frames may be replaced in case of failure.
Replacement fans are Grass Valley part number 1844-3000-200 for a Densité
3 frame,
#03007-2100-100 for a Densité 3+ FR4 frame, or #0969-2100 for a Densité 3+ FR1 frame.
Replacing the frame ventilation fan in a Densité 3 frame
To replace the frame ventilation fan in a Densité 3 frame
1 Remove the two screws that secure the grill and fan unit to the frame.
Retain the screws and grill, as they will be used with the replacement fan.
2 Pull the unit away from the frame, and disconnect the power feed by grasping the
connector and pulling straight out.
Grass Valley uses two different
fan units for this product. While
they are electrically equivalent,
they have slightly different
dimensions. The fan is installed
with two screws located on
opposite corners. The mounting
plate has two sets of corner holes
—
one to fit each of the available
fan models.
3 Start installing your new fan unit
with one corner screw, and then
try the diagonally opposite
corner to see if it fits. If not, use
the other pair of corners.
These two fan units also have
different power connection
configurations. There are two
identical power connectors
available on the frame for the
fan’s power cable. When you
install the fan, you will be able to
tell which one you should use:
only one will be within reach.
4 Grasp the power connector
attached to the fan assembly, and push it onto the appropriately-located power outlet
inside the cutout on the rear panel.