5.4 Configuration of the LioN-P
EtherNet/IP modules
5 Configuration and startup
Link
Connection type
Diagnostics Assembly ID
Length
Output: 192
0 byte
Input: 101
6 byte
8-bit in/out + diagnostic Listen Only
Yes
Configuration: n/a
0 byte
Output: 192
0 byte
Input: 102
3 byte
8-bit in/out
Listen Only
No
Configuration: n/a
0 byte
5.4.2 Configuration parameters
To transfer the configuration parameters, LioN-P uses different assembly
objects depending on the module type. These can be seen in section
Connections and assembly objects
on page 28.
Each LioN-P module has a fixed number of configuration parameters. This
variable is determined by the respective configuration assembly instance.
Length of the configuration parameters:
D
16DIO: 65/33 words (130/66 bytes) depending on the selected profile
D
16DI: 1 word (2 bytes)
D
16DO: 33 words (66 bytes)
D
8DI/8DO: 17 words (34 bytes)
The configuration parameters Surveillance Timeout (delay of the output
monitoring time of a channel) and Fail Safe (initial state of a channel in the
event of an error) are only available for LioN-P modules and 16DIO profiles
with output functionality (16DIO, 16DO, 8DI/8DO).
The configuration parameters Process Data Direction and IO-Mapping (bit
assignment of the channels) are only available for LioN-P 16DIO modules.
5.4.2.1 Surveillance Timeout Configuration (ms)
These parameters are provided to all module types with digital outputs. The
configuration can be used to set a delay time (Surveillance Timeout) that
Manual LioN-P EtherNet/IP
Version 2.0 11/2017
40