instead a single
Excess Tunnel Down Events
alarm and stops generating
additional
Tunnel Down
alarms. The
Tunnel Down
events are still tracked
through the tunnel’s performance monitoring statistics, allowing you to analyze
the behavior.
The
<num_of_alarms>
parameter ranges from 2 to 50. By default, the alarm
threshold is enabled with a setting of
5
, meaning that the
Excess Tunnel Down
Events
alarm is generated once 5
Tunnel Down
events occur in a day.
Alarms generated during a maintenance window do not count against the alarm
threshold. For details see,
“Defining a Maintenance Window” on page 55
Configuring the
Network Central
Router for
Layer 2 Tunneling
The specific configuration tasks and commands for the network central router
vary, depending on the type of router that is installed.
Refer to the
Tunnel Mobility Technical Bulletin
, available at
www.support.belairnetworks.com for guidance on configuring the router
portion of the tunnels.