Performing a Software Upgrade
May 31, 2010
Confidential
Document Number BDTM11001-A01 Released
Verifying a
Successful
Download
Verify that the new software downloaded successfully with the following
command:
/system/show loads verify
The
verify
option calculates and verifies the checksum. A bad checksum
indicates an issue with the load. If there are any issues, perform the download
again.
Example
/system# show loads verify
Application BankA
-----------------
Sw Version: BA100 9.0.0.S.2009.01.05.16.35 (r20884)
State: Running (next reboot)
CommitState: committed
Md5Sum: OK
Application BankB
-----------------
Sw Version: BA100 8.0.8.D.2008.09.18.18.18 (r19148)
State: Shadow
CommitState: committed
Md5Sum: OK
Bootloader Info
---------------
PPC405EP Common Bootloader Version 4.06 11/06/2008
Activating a
Software Load
To activate a software load, enter the following:
/system/reboot
The
reboot
command is only available if you are logged in as
root
.
This command forces the unit to execute with the new load and completes the
activation process.
When upgrading several nodes in a network, BelAir recommends that you
reboot the most remote node first and progress towards the near-end,
node-by-node. For star topologies, reboot the subscriber station nodes before
rebooting the associated base station node.
Note: Rebooting a unit as part of a software upgrade can take significantly
longer, up to 20 minutes, depending on the unit’s configuration.