background image

TET2200-12-086NA, TET2200-12-086NA Series

 

3

 

 

 

 

Asia-Pacific 

+86 755 298 85888

 

Europe, Middle East 

+353 61 225 977

 

North America 

+1

 

408

 

785 5200

 

© 2020 Bel Power Solutions & Protection

 

BCM.00594_1 

 

FUSING

 

 

SERVICING

LIMITED WARRANTY

NUCLEAR AND MEDICAL APPLICATIONS

TECHNICAL REVISIONS

OUTPUT CONNECTOR PIN ASSIGNMENT TET2200-12-086NA

Row A 

MATING SEQUENCE 

DESCRIPTION 

PIN 

NAME 

PIN TYPE 

P1-12, 

12V output 

12V Main Output 

STD 

12 VDC main output  

P13-24 

PWR Return 

Long 

12V Main and 12Vsb output return 

P25 

+12V Remote 

Sense Input 

Input 

STD 

12V Output Remote Sense  

P26 

12VSTBY 

Aux/Standby Power 

STD 

 

12VSTANDBY output  

P27 

A0 

Input 

STD 

Power Management Bus

 address A0  

P28 

PWOK 

Output 

STD 

Active high; indicates 12V Main is valid and within operational 
limits  

P29 

Signal Return 

Output 

Signal GND 

Long 

Signal GND; (MFBL) long connection  

P30 

SCL 

Bi-Directional; I/O 

Short 

I²C /SMBus/

 Power Management Bus

 Clock Line  

P31 

PRESENT 

Output 

Short 

Power Supply Present; passive signal to Signal Return  

P32 

SDA 

Bi-Directional; I/O 

Short 

I²C /SMBus/

 Power Management Bus

 Data Line  

F1 

Summary of Contents for TET2200-12-086NA

Page 1: ...chen Verletzungen Das Gehäuse des Gerätes kann heiß sein lassen Sie Zeit zum Abkühlen des Gerätes bevor Sie es berühren Lassen Sie keine Flüssigkeiten oder Fremdkörper in die Geräte eindringen Um Überschläge zu vermeiden schließen Sie das Gerät nicht an oder trennen Sie es nicht ohne vorher die Eingangsspannung abgeschaltet zu haben und warten Sie die Entladung der internen Kondensatoren ab mindes...

Page 2: ...5A 42W max SAFETY APPROVALS Approved to the latest edition of the following standards CSA UL 62368 1 EN IEC 62368 1 EN IEC 60950 1 GB 4943 1 CAUTIONS LIMITATIONS CAUTION Ⅰ PROTECTIVE EARTHING WARNING 声明 此为 A 级产品 在生活环境中 该产品可能会造成无线电干扰 在这种情况下 可能需要用户对其干扰采取切实可行的措施 身体部位远离风扇叶片 机器运行中或停机后一段时间内 请勿触摸外壳以防烫伤 设备只能被有资质的运维人员安装 设备应按百富指引安装或按此说明内定义的端口安装 POWER SUPPLY CORD SET LOADING CONDITIONS ENVIRONMENTAL CONDITIO...

Page 3: ...in output P13 24 PWR Return Long 12V Main and 12Vsb output return P25 12V Remote Sense Input Input STD 12V Output Remote Sense P26 12VSTBY Aux Standby Power STD 12VSTANDBY output P27 A0 Input STD Power Management Bus address A0 P28 PWOK Output STD Active high indicates 12V Main is valid and within operational limits P29 Signal Return Output Signal GND Long Signal GND MFBL long connection P30 SCL B...

Page 4: ...No End User Connection P32 SMB_Alert Output Short Active low I2C alert signal interrupt UNIT FRONT REAR AND LED INDICATOR TET2200 12 086NA Figure 3 Front view Figure 4 Rear view OPERATING CONDITION LED State Output ON and OK Solid GREEN No AC power to all power supplies OFF AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power OFF AC present Only 12 VS...