background image

 

 

 

 

In case there is hum or ground noise, check that the RCA/XLR switch is in the correct position for the type of 
connection being used. 

 

 

Ensure that the preamplifier or any source components are not producing hum by setting the preamplifier 
to a MUTE or Standby setting. 

 

 

The design of the REF1000

M

 reduces the chance for ground loop induced hum, but we still recommend 

using shorter interconnect cables to the preamplifier. Connect all power cables to a common outlet box or 
power conditioner unit to reduce the possibility for ground current noise being induced into the audio signal 
path. 
 

 

If you choose to power your source and preamplifier components from a different AC supply than used for the 
REF1000

M

 amplifiers, we recommend that you use a high quality balanced XLR cable driven from a true 

balanced XLR preamplifier output.  

 

 

We

 

do not recommend

 that you resort to ‘cheater plugs’ or some other means to disconnect the power 

ground from the REF1000

M

 as this may lead to dangerous operation and void the warranty. 

 

 

The small blue LED lamp indicates that power is connected to the REF1000

M

 and that the power switch is in 

the ON position. If the amplifier detects a fault or short circuit in the output connections then it will go into a 
protection mode and stop playing. If this occurs toggle the power switch to the OFF position and check the 
speaker cabling to ensure that no speaker output is either shorted together or connected to a ground. When 
you are certain that the loudspeaker cabling is correct, power the unit ON again, check that the blue LED is lit 
and that music will play. 

 

 

There is an internal fuse protection on the REF1000

M

. If the power switch is in the ON position, the power 

cable is connected to a functioning power outlet at the correct voltage and the blue LED is not lit, this 
indicates that the internal fuse may have blown. If this occurs contact your dealer, distributor or Bel Canto for 
service. There are no user replaceable fuses or other parts. Opening the chassis will void your warranty. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for REF1000m

Page 1: ......

Page 2: ... electronic mechanical photocopying recording or otherwise without the prior written permission of Bel Canto Design The content of this manual is provided for information use only is subject to change without notice and should not be construed as a commitment by Bel Canto Design Limited Bel Canto Design Limited assumes no responsibility or liability for any errors or inaccuracies that may appear i...

Page 3: ...may impede the flow of air through the ventilation openings Do not install near any heat sources such as radiators heat registers stoves or other apparatus that produce heat This apparatus uses Class I construction and must be connected to a mains socket with protective earthing connection Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and at t...

Page 4: ...dards EN55013 2001 Conducted emissions EN55013 2001 Absorbed emissions EN55020 2002 Immunity The conformity of the designated product with the provisions of Directive number 2005 32 EC ecodesign requirements is proved by full compliance with the off mode setting power of 0 0 Watts Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part ...

Page 5: ...orization number issued after completing the RMA form in the support section of our website If you have any questions please feel free to contact us online at info belcantodesign com REF1000M packaging contains the following 1 one REF1000M Amplifier 1 one REF1000M User s Guide 1 one Power cord 6 6 2 meters long Carefully unpack each piece and check for shipping damage If there is any damage or if ...

Page 6: ...on and improved input stage drive to the amplifier This circuit results in lower noise in real world operation lower distortion and better dynamic performance for the amplifier This input stage uses the latest advanced amplifiers and passive components including Caddock resistors Solid Electrolytic ultra low ESR decoupling capacitors and low noise regulated power supplies These devices ensure that...

Page 7: ...n using XLR cables insure that the switch is out in the XLR position Do not connect both XLR and RCA cables to the inputs 3 Output Connections Attach your loudspeaker to the output connectors Be sure that the polarity of each speaker is correct and the same so that no phase inversion can occur 4 IEC power cord jack Connect a heavy gauge power cord from this jack to the wall power supply Note the p...

Page 8: ...disconnect the power ground from the REF1000M as this may lead to dangerous operation and void the warranty The small blue LED lamp indicates that power is connected to the REF1000M and that the power switch is in the ON position If the amplifier detects a fault or short circuit in the output connections then it will go into a protection mode and stop playing If this occurs toggle the power switch...

Page 9: ...0 Output Impedance at 100Hz 8 milliohms Dynamic Range 120dB Input Voltage for Max Output 3Vrms Input connections Single ended RCA or balanced XLR RCA input impedance 100Kohms Balanced input impedance 200Kohms Output connections 1 set WBT 5 way safety binding posts Power On usage 15W Power Off usage 0 0W Internally Set Operating Voltages 100 120VAC or 230 240VAC 50 60 Hz Size 8 5 x 3 5 x 12 inches ...