2.   Introduction 

 

Congratulations for purchasing your new BEKO linear amplifier. You have purchased a 
quality product, individually built to the highest standards, and one that will last you a 
lifetime. Please take a few minutes to read this instruction manual and then store it in a safe 
place for future reference. Finally,

 

it’s up to you to insure that all components used in your 

system such as cables, connectors, preamps and coaxial relays can handle this amplifier’s

 

power level. 
The HLV-2000 is a solid state MOSFET VHF-amplifier covering the 144 – 148 MHz 
frequency range with a selectable gain of 16-23 db. The internal modulated power limit is 
kept to 2200 watts. It’s design is based on Freescale’s rf transistor MRFE6VP61K25H. 
Optimized output matching including h3-phase compensation and elliptic low pass filter 
ensure best efficiency, highest 1dB compression and high spectral purity. It is essential that 
the driving source has a narrow phase noise and high spectral purity. The output signal of an 
amplifier can’t be better than it’s input signal. 

 

      

 

                                                                            

   Intermodulation products @ 1,0 kW PEP        Intermodulation products @ 2,0 kW PEP 

 

 

      

HLV-2000

0

500

1000

1500

2000

2500

0

2,5

5

7,5

10

12,5

15

17,5

20

22,5

25

27,5

30

32,5

35

Input power [W]

O

u

tp

u

p

o

w

e

[W

]

  

   Harmonic attenuation @ 2 kW CW 

  

                Output vs input 

 

The following models are available:    

HLV-2000-10 
HLV-2000-20 
HLV-2000-30 
HLV-2000-45 

Summary of Contents for HLV-2000

Page 1: ...1 HLV 2000 Instruction Operations Manual ...

Page 2: ...instructions 5 4 Electrical connections 6 5 Warranty 7 6 Front panel operation 8 7 Protection circuits 9 8 Receive Transmit switching 10 9 Remote control 11 10 Cooling technique 12 11 Block diagram 13 12 Adjustment of protection thresholds 14 13 Control circuit schematic 15 14 tbt ...

Page 3: ... EC and 99 5 EC EN 301 783 1 V1 1 1 2000 09 EN 301 783 2 V1 1 1 2000 09 EN 301 489 1 V1 6 1 2005 09 EN 301 489 15 V1 2 1 2002 08 EN 60950 1 2006 All necessary test procedures have been successfully passed Manufacturer and authorized representative BEKO ELEKTRONIK Am Längenmoosgraben 1a D 85221 Dachau GERMANY This declaration has been accomplished under unique reponsability of the manufacturer BEKO...

Page 4: ...le gain of 16 23 db The internal modulated power limit is kept to 2200 watts It s design is based on Freescale s rf transistor MRFE6VP61K25H Optimized output matching including h3 phase compensation and elliptic low pass filter ensure best efficiency highest 1dB compression and high spectral purity It is essential that the driving source has a narrow phase noise and high spectral purity The output...

Page 5: ... 5 C 32 C or 40 F 104 F and at humidity of less than 85 In order to avoid malfunction caused by condensation you will have to wait at least one hour before start of operation and until the condensation has been removed 6 To prevent electrical shock do not remove the cover before disconnecting the mains plug 7 The bottom openings are used as a cooling air inlet and the rear side outlet to exhaust t...

Page 6: ...chieve optimum driving level and maximum output power all load and source impedances should also be 50 Ohms Deviations will automatically cause limitation of the specifications and shifting of the threshold voltages of the protection circuits Operation with no load connected is not allowed 5 The RF connectors are N type Only high quality connectors with PTFE insulation must be used Neglecting will...

Page 7: ...test CE conformity and FCC rules We grant a 2 years warranty including parts and labour beginning from the date of purchase Unauthorized use or improper handling will invalidate all claims on warranty The device is protected by an invisible seal against opening Damage of the seal will invalidate the warranty Warranty is also excluded if damages are caused by 1 Overdrive with power levels 75W or wi...

Page 8: ... the preamplifier When returning to receive it turns the preamplifier on after switching off the RF power unit The supply voltage for the use of an external preamplifier is available on pin 4 of the CONTROL jack at the rear panel It is short circuit protected by use of a ptc fuse and supplies 15 volts 750 mA Preamps that only can accept voltage feed via the coaxial cable can t be used with this am...

Page 9: ...7 Protection circuits The HLV 2000 s internal control circuit supervises the output load condition any overdrive of the input stage and the thermal status of heat sink and power supply unit If the amount of reflected power exceeds 100 watts the protection circuit shuts off the RF unit immediately and switches the drive power to bypass mode This also happens with overdrive levels of more than 15 of...

Page 10: ...r contact of the rear sided AUX jack to reliably control a connected transceiver Any potential at the inner conductor is switched to ground In essence your amplifier provides a built in multi level sequencer which provides an alternate means to key your radio last When the amplifier PTT is activated usually via a foot switch the preamp voltage is dropped first internal relays are switched the RF a...

Page 11: ... can easily be activated by an external switch wired to ground Output power can be monitored 100 of output power is equal to 10V DC on Pin 5 Use the 7 pin DIN plug that was delivered with your amplifier and connect the other end to a suitable connector to your transceiver or other switching unit ...

Page 12: ... rise of balun and output filter coils To achieve best airflow for cooling the air in and outlets must not be covered Do not operate the amplifier in close proximity to heaters and radiators If thermal shut down occurs you should wait until the device temperature decreases sufficiently before switching on the amplifier again Please read also our Safety instructions and Electrical connections ATTEN...

Page 13: ...13 11 Block diagram 12 Adjustment of protection thresholds ...

Page 14: ...nd need some slight correction In the picture below all trimpots incl their functions are shown Turning the slots clockwise is equal to or upward direction and verse vice Readjustment should be done very carefully otherwise the effect of protection is cancelled ...

Reviews: