18/EN
Unless there is an abnormal
condition, do not attempt to
remove the gas burner taps. You
must call an Authorised service
agent or technician with licence if
it is necessary to change the taps.
Reduced gas flow rate setting for
hob taps
1. Ignite the burner that is to be adjusted
and turn the knob to the reduced
position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver
to adjust the flow rate adjustment
screw.
For LPG (Butane - Propane) turn the
screw clockwise. For the natural gas,
you should turn the screw
counter-
clockwise
once.
»
The normal length of a straight flame in
the reduced position should be 6-7 mm.
4. If the flame is higher than the desired
position, turn the screw clockwise. If it
is smaller turn anticlockwise.
5. For the last control, bring the burner
both to high-flame and reduced
positions and check whether the flame
is on or off.
Depending on the type of gas tap used
in your appliance the adjustment screw
position may vary.
1 Flow rate adjustment screw
1 Flow rate adjustment screw
If the gas type of the unit is
changed, then the rating plate
that shows the gas type of the
unit must also be changed.
Leakage check at the injectors
Before carrying out the conversion on
the product, ensure all control knobs are
turned to off position. After the correct
conversion of injectors, for each
injectors should be gas leak checked.
1.
Make sure that the gas supply to the
product is on, still maintaining all
control knobs turned to off position.
2.
Each injector hole is blocked with a
finger applying reasonable force to
stop the gas leakage when
corresponding control knob turned to
on and it held at depressed position to
allow gas reach the injector.
3.
Apply prepared soapy water at the
injector connection with a small brush,
if there is leakage of gas at the injector
connection the soapy water will begin
to froth. In this case, tighten the
injector with a reasonable force and
repeat step 3 process once again.
4.
If the froth still persist you must turn
off the gas apply to the product
immediately and call an Authorised
service agent or technician with
licence. Do not use the product until