23 / EN
Dryer / User Manual
Maintenance and cleaning
C
Clean metal surfaces of the
sensors 4 times a year.
C
Do not use metal tools when
cleaning metal surfaces of the
sensors.
A
CAUTION:
Never use solvents,
cleaning agents or similar
substances for cleaning due to
the risk of fire and explosion!
6.3 Draining the water tank
Dampness of the laundry is removed and
condensed during drying process and the
water that arise accumulates in the water
tank. Drain the water tank after each drying
cycle.
A
Condensed water is not drinkable!
A
CAUTION:
Never remove the
water tank when the program is
running!
If you forget to drain the water tank, the
machine will stop during the subsequent
drying cycles when the water tank is full and
the Water Tank warning symbol will flash.
If this is the case, drain the water tank and
press
Start / Pause
button to resume the
drying cycle.
To drain the water tank:
1. Remove the water tank in the drawer or
container carefully.
2. Drain the water in the tank.
3. If there is lint accumulation in the funnel
of the water tank, clean it under running
water.
4. Place the water tank into its seat.
6.4 For the condenser;
Hot and humid air in the condenser is cooled
with the cold air from the room. Thus,
the humid air circulating in your dryer is
condensed and then pumped into the tank.
C
Clean the condenser after every
30 drying cycles or once a month.
To clean the condenser:
1. If a drying process has been carried out,
open the door of the machine and wait
until it cools down.