Installation and operating manual
EN
30
DRYPOINT
®
M eco control
7. Maintenance and servicing
7.1. Maintenance schedule
Maintenance
Interval
Function and visual inspection Refer to 7.1.1
Regularly
Replace the filter element and float drain
•
Exchange the filter element
•
Exchange the float drain
annually
Wear part exchange Refer to 7.1.4Refer to 7.1.4
•
Exchange of the wear parts
Cycle: see
“7.1.4. Wear part exchange” on Page 39
7.1.1. Function and visual inspections
To ensure that the device is in proper working order, the system owner and/or operator must execute regular function and
visual inspections:
• Inspect the device for trouble-free functionality
purge air outlet, damage on the housing, leaks, defects on electrical connections
• Inspect the device for error indications
→
For additional information refer to “9. Remedying malfunctions, errors, faults and troubleshooting” on Page 52
• Inspect the device for external soiling and contamination and clean if necessary
→
For additional information refer to “Cleaning” on Page 50