Machine takes
much water and
overflows
Select the funcitonal test mode.
Start the functional test. Does the
drain pump work?
No
Yes
Check the drain
hose
Check the drain
pump and the
connections
Check the water
inlet valve
Check the over
flow gauge, over
flow switch and the
connections
TROUBLESHOOTING GUIDE FOR A3 TYPE DW’S