Maintenance
42
CLEARPOINT® L 205 – L295 V
16.2 Maintenance in general
The plant must be checked at regular intervals in accordance with the applicable national regulations. In
this respect, the following points need to be observed:
In order to ensure high operational and performance reliability, regular maintenance measures
are required.
Watch for abnormalities and possible malfunctions during the running operation.
Deficiencies must immediately be reported to the responsible units/persons.
For emergency cases, there must be the possibility to cut off the plant section.
16.3 Maintenance of the CLEARPOINT
®
V activated-carbon adsorber
Action
daily
weekly
annually*
Check the exterior of the plant for contaminations,
damages and corrosion
x
Record the current operating parameters and compare
them with the indications under "Technical data"
x
Check the manometer
x
Check all pipe connections and threaded connections and
retighten them if necessary
x
Check the activated-carbon adsorber for leaks
x
Verify the result of the oil adsorption (e.g. by means of a
METPOINT
®
OCV or a laboratory analysis)
x
Replace the activated carbon
x
* or every 10,000 operating hours