![Beko BKFO 160 Installation Manual Download Page 10](http://html.mh-extra.com/html/beko/bkfo-160/bkfo-160_installation-manual_27603010.webp)
10 / 48 EN
Air conditioner inverter / Installation manual
A
Warning:
Avoid the following places for installation where air conditioner trouble is liable to
occur.
•
Where there is much machine oil.
•
Salty places such as seaside.
•
Where sulfide gas is generated such as a hot spring.
•
Where there is high-frequency or wireless equipment.
C
Note:
When operating the air conditioner in low outside temperature, be sure to follow the
instruction describe below.
•
Never install the outdoor unit in a place where its air inlet/outlet side may be exposed
directly to wind.
•
To prevent exposure to wind, install the outdoor unit with its air inlet side facing the
wall.
•
To prevent exposure to wind, it is recommended to install a baffle board on the air outlet
side of the outdoor unit.
4.1 Free space required around outdoor unit (unit: mm)
Obstacles
When there is an obstacle around the outdoor unit, it does not matter if the position of the obstacle as
shown in the figures below.
1. Obstacle over the top side.
2. Obstacle in three direction (but top side is
open).
500 or more
100 or more
200 or more
100 or more
350 or more
4