4.4 Climatic zones and performance data
Depending on which climatic zone the product is used in, the product performance differs depending on the climatic
ambient conditions.
Climatic zone
Max. compressor performance
Max. dryer performance
Unit
m³/min.
cfm
m³/min.
cfm
green
1700
60034
3400
120069
blue
1400
49440
2800
98881
red
1000
35314
2000
70629
The performance data given refer to a moderate climate valid for Europe, large parts of South-East Asia, North and South
Africa, parts of North and South America (climatic zone: blue).
For a dry and / or cool climate (climatic zone: green), the following factor applies:
Performance in climatic zone “blue”
x
approx. 1.2
For a hot and / or humid climate (tropics, climatic zone: red), the following factor applies:
Performance in climatic zone “blue”
x
approx. 0.7
4.4.1 Performance data
BEKOMAT
®
16 CO
Max. compressor
performance
1700 m³/min
60034 cfm
Max. refrigeration dryer
performance
3400 m³/min
120069 cfm
Operating pressure
1 bar(g)
14.5 psi(g)
2 bar(g)
29.01 psi(g)
3 bar(g) … 4 bar(g)
43.51 psi(g) … 58.01 psi(g)
5 bar(g) … ≥7 bar(g)
72.52 psi(g) … ≥101.52 psi(g)
Ø discharge rate
226 l/h
59.70 gal/h
243 l/h
64.19 gal/h
263 l/h
69.47 gal/h
274 l/h
72.38 gal/h
Max. discharge rate (short-
term)*
950 l/h
250.96 gal/h
1150 l/h
303.79gal/h
1400 l/h
369.84 gal/h
1700 l/h
449.09 gal/h
* The peak volume can only be achieved if the device is correctly installed according to the installation and operation
manual. If in doubt, a venting line must be installed.
BEKOMAT
®
16 CO
Original installation and operation manual
16 | 60
Summary of Contents for BEKOMAT 16 CO
Page 1: ...EN BEKOMAT 16 CO 01 3582 Original installation and operation manual BM16CO ...
Page 55: ...Original installation and operation manual BEKOMAT 16 CO 55 60 ...
Page 58: ...BEKOMAT 16 CO Original installation and operation manual 58 60 ...
Page 59: ...Original installation and operation manual BEKOMAT 16 CO 59 60 ...