Multi line pump OC-1
Operation method of BEKA-troniX1
If no signal is received from the pump motor for longer than
the adjustable monitoring time (standard 30 sec.) after the
lubricating process has begun, then the controller will
indicate a fault.
The red LED in the pump´s lower motor casing display or an
externally attached signal lamp (optional) will start to flash.
A) Time controller:
When the central lubrication processor is time controlled,
the cycle
and the lubrication time can be adjusted.
time
Cycle
means the period from the beginning of one
time
lubrication process to the beginning of another lubrication
process.
B) Revolution controller:
In the case of revolution fluctuations at lower temperatures
or high torque, the lubrication
for the BEKA-troniX1
time
integrated electronic controller is determined by the
number of pump motor revolutions.
The pump motor is connected to the controller via sliding
contacts. With every engine revolution a signal is sent to the
controller, which counts the incoming signals.
Diagram of cycle sequence:
Lubrication time
Cycle time
Subject to alterations!