en | 2 | BD 6xx | Short Operation Manual Brake Tester BD 6xx 

Beissbarth GmbH 

1 691 606 421 | 2010-07-12 

Automatic Operation 

 

 

  or    

 

 

 

Switch on automatic 

 

Remote control 
button 

 

Press button at the 
display cabinet for 1 
second 

 

Red lamp ON 

 

Important! 

No vehicle is positioned 
on the roller set 

 

 

 

Move vehicle across 
test stand 

 

Green lamp ON 

Red lamp ON 

 

 

Red lamp flashes during 

roller resistance 

measuring 

Measuring operation 

Switching off criteria 

 

slip control 

 

Sensoring rollers no 
longer pressed down 

 

After a brake test, the 
brake effect is at the 
level of the roller 
resistance for more 
than 6 seconds. 

 

 

 

Ovality measuring 

 

Brake forces left and 
right larger than 1000 

 

Reduce brake force 
to roller resistance 

 

Maintain brake force 
larger than 500N 
constant 

 

Measuring starts after 
3 seconds 

 

 or    

 

 

End automatic 
operation 

 

Superautomatic Operation 

 

 

 

+

 or    

 

 

 

Switch on 
superautomatic 

 

Remote control 
button 

 

Press button at the 
display cabinet for 3 
seconds 

 

Red lamp ON 

Flashing part order 
number on the middle 
LCD 

 

Important! 

No vehicle is positioned 
on the roller set 

 

 

Flashing part order 

number on the middle 

LCD 

Move vehicle across 
test stand 

Allocation of part order 
numbers and test 
sequence 

 

Part order  1 = front 
axle  

 

Part order 2 = rear 
axle  

 

Part order P = 
parking brake 

IMPORTANT!  

The test sequence must 
be maintained! 

 

 

Red lamp flashes during 

roller resistance 

measuring 

Measuring operation 

Switching off criteria 

 

Slip control 

 

Sensoring rollers no 
longer pressed down 

 

After a brake test, the 
brake effect is at the 
level of the roller 
resistance for more 
than 6 seconds. 

 

 

 

Ovality measuring 

 

Brake forces left and 
right larger than 1000 

 

Reduce brake force 
to roller resistance 

 

Maintain brake force 
larger than 500N 
constant 

 

Measuring starts after 
3

 

 

 

 

 

 

 

“decreasing hourglass” 

Repetition of the part 
order 

 

Peak value display 
finished 

 

3 seconds waiting 
time 

 

short brake impulse 

Repeat measurement 
starts 

Caution 

Deactivated in the 
standard configuration! 

 

 

 

Parking brake on the 
front axle 

 

Upper LCD shows  
„[ ]“ 

 

Short braking 
impulse, Change to 
parking brake 

 

Measurement starts 

Caution 

Deactivated in the 
standard configuration! 

 

 

 

Driving support 

 

Measurement ended 

 

Motors remain 
switched on 

 

Leave roller set 

 

 

 

Automatic printout via 
printer box 

Standard printer 

 

Olivetti DM 109 

 

Seikosha SP-2400 

LCD display 

 

print message 

 

# No of printouts 

 

 or    

 

 

End Superautomatic 

 

 