en | 2 | BD 6xx | Short Operation Manual Brake Tester BD 6xx
Beissbarth GmbH
1 691 606 421 | 2010-07-12
Automatic Operation
or
Switch on automatic
•
Remote control
button
•
Press button at the
display cabinet for 1
second
Red lamp ON
Important!
No vehicle is positioned
on the roller set
Move vehicle across
test stand
Green lamp ON
Red lamp ON
Red lamp flashes during
roller resistance
measuring
Measuring operation
Switching off criteria
•
slip control
•
Sensoring rollers no
longer pressed down
•
After a brake test, the
brake effect is at the
level of the roller
resistance for more
than 6 seconds.
Ovality measuring
•
Brake forces left and
right larger than 1000
N
•
Reduce brake force
to roller resistance
•
Maintain brake force
larger than 500N
constant
•
Measuring starts after
3 seconds
or
End automatic
operation
Superautomatic Operation
+
or
Switch on
superautomatic
•
Remote control
button
•
Press button at the
display cabinet for 3
seconds
Red lamp ON
Flashing part order
number on the middle
LCD
Important!
No vehicle is positioned
on the roller set
Flashing part order
number on the middle
LCD
Move vehicle across
test stand
Allocation of part order
numbers and test
sequence
•
Part order 1 = front
axle
•
Part order 2 = rear
axle
•
Part order P =
parking brake
IMPORTANT!
The test sequence must
be maintained!
Red lamp flashes during
roller resistance
measuring
Measuring operation
Switching off criteria
•
Slip control
•
Sensoring rollers no
longer pressed down
•
After a brake test, the
brake effect is at the
level of the roller
resistance for more
than 6 seconds.
Ovality measuring
•
Brake forces left and
right larger than 1000
N
•
Reduce brake force
to roller resistance
•
Maintain brake force
larger than 500N
constant
•
Measuring starts after
3
s
“decreasing hourglass”
Repetition of the part
order
•
Peak value display
finished
•
3 seconds waiting
time
•
short brake impulse
Repeat measurement
starts
Caution
Deactivated in the
standard configuration!
Parking brake on the
front axle
•
Upper LCD shows
„[ ]“
•
Short braking
impulse, Change to
parking brake
•
Measurement starts
Caution
Deactivated in the
standard configuration!
Driving support
•
Measurement ended
•
Motors remain
switched on
•
Leave roller set
Automatic printout via
printer box
Standard printer
•
Olivetti DM 109
•
Seikosha SP-2400
LCD display
•
print message
•
# No of printouts
or
End Superautomatic