![Beisler 1281/4 Series Operating Instructions Manual Download Page 30](http://html.mh-extra.com/html/beisler/1281-4-series/1281-4-series_operating-instructions-manual_2723767030.webp)
2-4
2.2.2
Connection of air supply
1
2
3
4
5
1. Connect the air pipe (2) to your air system.
2. Open the air supply of your air system.
3. Level the air pressure to 6 bar using the control (1); the air pressure can be
read at the scale (3).
4. Water collected in the water separator (4) can be released by pressing on
the valve (5).
Attention
We recommend to switch off the air supply when the machine is not in duty.
Use the control (1).
2.3
Elektrical installation
Hint
All work at the electrical components of the machine may only be carried by
qualified staff (qualified electrical employee or instructed person according to
IEC 364 and DIN EN 60204-1).
Danger
Parts under electrical current! Without cutting off the power supply, you might
be injured severely. Please obey the security advice given in chapter 1.
Attention
The machine will be destroyed by connecting to a wrong mains voltage!
Check, whether the requirements from chapter ‘Technical data’ meet the
local conditions.