Service Instructions Automatic Single-Head Serging Machine 1265-4
Beisler GmbH
C-5
C.2
Location requirements
C.2.4 Supply connections
The machine requires on-site power supply cables with a minimal
cross-section of 1.5 mm and a connection to a compressed-air supply
system.
Power supply connection:
The power supply of the machine requires a properly grounded power
supply connection with:
Grounding plug
230 V ± 10 %, 50/60 Hz
Fusing
16 A
NOTE - Peak voltages
The correct function of the machine requires that the po-
wer supply system supplies a constant current. Peak
voltages may particularly impair the stability of the pro-
gram control.
Compressed-air supply:
The on-site compressed-air supply system must meet the following re-
quirements:
Operating pressure
6 bar
Compressed-air quality
oil-free
Compressed-air consumption
40 NL / AT