RS232 Control commands

Command

Function

Feedback Example

Switch

SW [x] [y] [y] [y]

x: Inport number
y: outport number
SW 1 1 2 3 4: switch input 1 to output 1,2,3,4.
Return: SWS 1 1 1 1
SW 2 2: switch input 2 to output 2
Return: SWS 1 2 1 1

Get Switcher GetSW

Return :SWS 1 1 1 1

Get

FW

version

GetMCUFWVer

Return: MCUVer 01.01.00

Select Edid

SetEDID [x] [y]

x: Inport number
y: Edid selected, reference to Table1: Item
number value.
Eg. SetEdid 1 10

Set Outport1 Edid to Inport 1,

Set

Edid

Data

SetEDIDData [x] [y]

x: Edid select: Refet table1 item number

The Value is 1~9,

y: Edid Data

Eg.SetEDIDData 1 00 FF FF FF FF FF FF....

Get

Edid

Data

GetEDIDData x

x: Edid select: Refet table1 item number

The Value is 1~9,

Eg. GetEDIDData 1
Return: EDIDData 1 00 ff ff ff ff ff ff 00....

Set Output
HDCP

SetOutPortHDCP [x] [y]

x: output port
y: 0 is Off 1: Is On 2:is following input

Summary of Contents for FIX-MANAGER-400-4K60

Page 1: ...1 Version V2 0 1 4K60 4x4 HDMI Matrix Switcher User Manual ...

Page 2: ...4 4 4 Supports HDR Supports real time monitoring with the LCD screen Supports remote control RS232 and TCP IP Supports powerful EDID management Supports USB firmware upgrade Fixed chassis with 19 mountable design 3 Specification 4 Panels Power Switch Name HDMI2 0 4K60 4x4 HDMI matrix switcher Input 4 HDMI 1 RS232 1 RJ45 Output 4 HDMI 1 COAX Protocol Supports HDMI2 0 HDCP2 2 HDR and EDID management...

Page 3: ...onfirm button RECALL User mode recall button IR receiver OUTPUT selection buttons HDMI input ports HDMI outputs ports COAX audio de embedded port Upgrade port IR port RS232 control port RJ45 IP control 12V power adapter connect port 5 Connection diagram Note the above image is only for this user manual please refer to the real application or the equipment 6 Packing details ...

Page 4: ...ts Steps input output output ENTER Eg Switch input 2 to output 2 4 C Switch one input to all the outputs Steps input ALL ENTER Eg Switch input 1 to all the outputs Note If switch success the light will flash for 3 times 7 1 2 EDID Management A EDID learning for the outputs Steps EDID INPUTS UP DOWN ENTER Eg Input 2 learn the EDID from output 4 B All inputs are learning the EDID from one output Ste...

Page 5: ...ssless 4K30 2CH PCM 22 4K60420StereoHDR 4K30 2CH HDR 23 4K60444Stereo 4K60 4 4 4 2CH 7 2 Look up 7 2 1 Look up the status Press and hold ENTER for 5s it will access to the look up menu then press UP DOWN button to check Function Items Example Description Switche Status IN 1 2 3 4 OUT 1 2 3 4 Shows the correspondence between the 4 inputs and 4 outputs Check the connection status of inputs IN 1 2 3 ...

Page 6: ...not Check the output resolution RESOLUTION OUT 1 0000 0000 Press OUTPUT Keys direction button to check all the 4 output resolutions IP Address IP ADDRESS 192 168 1 121 Machine IP address 7 2 2 Remote Control 7 2 3 RS232 control Use the straight connection RS232 cable USB RS232 cable can be used directly Baud rate 115200 Data Bit 8 Stop bit 1 Parity Bit None RS232 connection pin definition Power Pr...

Page 7: ...1 00 Select Edid SetEDID x y x Inport number y Edid selected reference to Table1 Item number value Eg SetEdid 1 10 Set Outport1 Edid to Inport 1 Set Edid Data SetEDIDData x y x Edid select Refet table1 item number The Value is 1 9 y Edid Data Eg SetEDIDData 1 00 FF FF FF FF FF FF Get Edid Data GetEDIDData x x Edid select Refet table1 item number The Value is 1 9 Eg GetEDIDData 1 Return EDIDData 1 ...

Page 8: ...8 1 121 This command is avalid for static ip mode And need powr on again Get IP GetIP Return IP 192 168 1 121 Set IP mask SetIPMask x x x x Eg SetIPMask 255 255 255 0 Return IPMask 255 255 255 0 Scence Save ScenceSave x Save current switcher to scence x 0 9 Scence call ScenceCall x Recall the scence saving X 0 9 Power on PWRON Pown on when in power saving Power off PowerOff Eneter Power saving Loc...

Page 9: ...9 The default password for Administrator is admin and the password for user is 1234566 After log in it will show below interface for the input and output switching Users Setting ...

Page 10: ...10 Name setting HDCP and EDID Management ...

Page 11: ...11 IP address setting ...

Reviews: